50 Ohm coaxial cable RG213 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °CBend minimum: 15xO.D. (unarmored) or 20xO.D. (armored)

 

 

Design

Conductor : bare copper 7×0.76mm 
Dielectric : polyethylene nominal Ø 7.25mm
Screen : bare copper wire braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 213 type MIL LSZH – 75 OHM – P/N – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 213 type MIL LSZH – 75 OHM – P/N – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

Electrical characteristics

Impedance : 50 ± 3 ᘯ 
Capacitance : 101pF/m nominal
Velocity ratio : 66%
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 100 200 400 600 800 1000
dB 7.2 11.0 15.5 21.0 25.0 29.0

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG213 Non-armoured RG213MT 10.2 163 500m or 1000m (+/-5%)
RG213 armoured GSWB RG213MTBH 14.5 250 500m (+/-5%)
RG213 armoured TCWB RG213MTTH 14.5 235 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


50 Ohm coaxial cable RG214 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °CBend minimum: 15xO.D. (unarmored) or 20xO.D. (armored)

 

 

Design

Conductor : bare copper 7×0.76mm 
Dielectric : polyethylene nominal Ø 7.25mm
Screen 1 : silvered copper wire braid
Screen 2 : silvered copper wire braid 

Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 214 type MIL LSZH – 75 OHM – P/N – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 214 type MIL LSZH – 75 OHM – P/N – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

Electrical characteristics

Impedance : 50 ± 3 ᘯ 
Capacitance : 101pF/m nominal
Velocity ratio : 66%
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 100 200 400 600 800 1000
dB 7.0 10.5 15.0 20.0 23.5 28.5

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging
RG214 Non-armoured RG214MT 10.8 200 500m or 1000m (+/-5%)
RG214 armoured GSWB RG214MTBH 15.2 290 500m (+/-5%)
RG214 armoured TCWB RG214MTTH 15.2 275 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


75 Ohm coaxial cable RG11 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °CBend minimum: 15xO.D. (unarmored) or 20xO.D. (armored)

 

 

Design

Conductor : tinned copper Ø 1.63mm nominal
Dielectric : polyethylene nominal Ø 7.20mm
Screen 1 : aluminium tape
Screen 2 : copper wire braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 11 type MIL LSZH – 75 OHM – P/N – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 11 type MIL LSZH – 75 OHM – P/N – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

Electrical characteristics

Impedance : 75 ± 3 ᘯ 
Capacitance : 53pF/m nominal
Velocity ratio : 82%
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 100 200 400 600 800 1000
dB 4.7 6.5 9.5 12.3 14.0 16.2

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG11 Non-armoured RG11MT 10.0 145 500m or 1000m (+/-5%)
RG11 armoured GSWB RG11MTBH 14.2 232 500m (+/-5%)
RG11 armoured TCWB RG11MTTH 14.2 218 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


75 Ohm coaxial cable RG59 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -10 to +70 °CBend minimum: 5xO.D. (unarmored) or 15xO.D. (armored)

 

 

Design

Conductor : copperweld Ø 0.58 ± 0.025 mm
Dielectric : low density polyethylene nominal Ø 3.70mm
Screen 1 : aluminium/poleysther/aluminium tape
Screen 2 : bare copper braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 59 type MIL LSZH – 75 OHM – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 59 type MIL LSZH – 75 OHM – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

 

Electrical characteristics

Impedance : 75ᘯ nominal 
Capacitance : 67pF/m nominal
Inner conductor resistance @ 500V : 154Ω/km nominal
Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 4.0 5.4 9.3 14.7 19.0 23.6 29.8 32.0 37.5 42.6 51.7 54.8 59.2 65.6 69.7 73.0 77.7 61.1

 

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG59 Non-armoured RG59MT 6.2 57.2 500m or 1000m (+/-5%)
RG59 armoured GSWB RG59MTBH 9.4 144.2 500m (+/-5%)
RG59 armoured TCWB RG59MTTH 9.4 130.0 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


50 Ohm connector BNC

   

Features

  • Straight and right angle
  • For flexible, semi-flex and semi-rigid cables
  • PCB connectors (straight and right angle)
  • Panel connectors in various flanges
  • Adapters

 

Application

  • Cable Assembly
  • Antenna, CATV, Satcom
  • Automotive
  • Medical Equipment
  • Radios, Telecommunications, Base Stations
  • Instrumentation

 

Materials

Body, coupling nut   Brass, Zinc alloy(diecast)
Insulator   Teflon, Delrin
Center contact   Brass for male / Beryllium copper or Phosphor bronze for female
Crimping sleeve   Annealed Brass
Body plating   Nickel (Ni)
Center contact plating   Gold (Au)

 

Electrical Characteristics

Impedance   50 Ohm
Frequency range   0-4 GHz

VSWR   Straight type ≤ 1.3 max
Dielectric withstanding voltage   1500 V rms
Working voltage   500 V rms
Center contact resistance   ≤ 1.5 mΩ (Milliohms max.)

Outer contact resistance   ≤ 2.0 mΩ (Milliohms max.)
Insulation resistance   ≥ 5000 MΩ (Megohms min.)

 

Mechanical Characteristics

Coupling   2-stud bayonet
Contact Retention   100 lbs. min.
Vibration   MIL-STD-202 Meth. 204
Corrosion resistance   MIL-STD-202 Meth. 101

 

Environmental Characteristics

Temperature Range   Teflon −65ºC ~ +85 ºC
Coupling nut retention   100 lbs. min.
Vibration   MIL-STD-202 Meth. 204
Corrosion resistance   MIL-STD-202 Meth. 101

 

Note : all characteristics and values are typical.

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


75 Ohm Coaxial cable RG6 CCS double screen PVC

 

Installation Features

Store at  -10 to +50 °C
Install at  -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -0 to +60 °CBend minimum : 20 times O.D.
Pull maximum : 100N

 

Design

Conductor :  solid CCS 1.02mm
Dielectric :  foam PE nominal Ø 4.60mm
Screen 1 :  bonded AL/P nominal Ø 4.75mm
Screen 2 :  Aluminium wire braid nominal coverage 60%

Jacket : black PVC material nominal Ø 6.86mm
Marking :  APS Finland – ww/yy – 75 Ohm CATV RG6 CCS – P/N CCS6AB6VKB3 – lot – meter

 

Environmental properties and Fire Performances

Flame retardant : IEC60332-1-2

 

Electrical Characteristics

Characteristic impedance (Ohm) 75+/-3
Capacitance (pF/m) 52+/-2
Velocity of Propagation (%) 85.0
Return Loss (dB) 5-1000MHz ≥22

Frequency Attenuation
db/100ft
Attenuation
dB/100 meter
55 1.6 5.2
187 2.8 9.3
211 3.1 10
400 4.1 13.5
500 4.6 15.0
750 5.6 18.5
860 6.1 20.0
1000 6.6 21.5

 

Recommended connectivity

BNC connectors : APS BNC75

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


75 Ohm connector BNC

   

Features

  • Straight and right angle
  • For flexible, semi-flex and semi-rigid cables
  • PCB connectors (straight and right angle)
  • Panel connectors in various flanges
  • Adapters

 

Application

  • Cable Assembly
  • Antenna, CATV, Satcom
  • Automotive
  • Medical Equipment
  • Radios, Telecommunications, Base Stations
  • Instrumentation

 

Materials

Body, coupling nut   Brass, Zinc alloy(diecast)
Insulator   Teflon, Delrin
Center contact   Brass for male / Beryllium copper or Phosphor bronze for female
Crimping sleeve   Annealed Brass
Body plating   Nickel (Ni)
Center contact plating   Gold (Au)

 

Electrical Characteristics

Impedance   75 Ohm
Frequency range   0-1 GHz

VSWR   Straight type ≤ 1.3 max
Dielectric withstanding voltage   1500 V rms
Working voltage   500 V rms
Center contact resistance   ≤ 1.5 mΩ (Milliohms max.)

Outer contact resistance   ≤ 2.0 mΩ (Milliohms max.)
Insulation resistance   ≥ 5000 MΩ (Megohms min.)

 

Mechanical Characteristics

Coupling   2-stud bayonet
Contact Retention   100 lbs. min.
Vibration   MIL-STD-202 Meth. 204
Corrosion resistance   MIL-STD-202 Meth. 101

 

Environmental Characteristics

Temperature Range   Teflon −65ºC ~ +85 ºC
Coupling nut retention   100 lbs. min.
Vibration   MIL-STD-202 Meth. 204
Corrosion resistance   MIL-STD-202 Meth. 101

 

Note : all characteristics and values are typical.

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


75 Ohm coaxial cable RG6 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °CBend minimum: 5xO.D. (unarmored) or 15xO.D. (armored)

 

 

Design

Conductor : bare copper Ø 1.02mm nominal
Dielectric : low density polyethylene nominal Ø 4.60mm
Screen 1 : aluminium tape
Screen 2 : aluminium wire braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 6 type MIL LSZH – 75 OHM – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 6 type MIL LSZH – 75 OHM – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

Electrical characteristics

Impedance : 75 ± 3 ᘯ 
Capacitance : 53pF/m nominal
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 100 200 300 400 600 800 1000
dB 7.0 10.2 12.0 14.8 18.5 20.8 24.8

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG6 Non-armoured RG6MT 7.0 110 500m or 1000m (+/-5%)
RG6 armoured GSWB RG6MTBH 11.2 197 500m (+/-5%)
RG6 armoured TCWB RG6MTTH 11.2 183 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


LIACC FO Access cable ADSS 2-72 cores, Mid Span.

    
*All images are indicative

 

Features

Aerial installation on HT power lines
All Dielectric Non-Metallic design
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -40 to +70 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with jelly (nominal dial. 2.5 ± 0.1mm)
Central member :  FRP (nominal diameter 2.0mm).
Assembling :  tubes and fillers assembled together according to “Colour Code” table
Wrapping :  water blocking tape.
inner jacket :  Black MDPE material

Peripheral element :  aramide yarns with ripcord.
Outer jacket :  Black HDPE material, UV resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable ADSS MT80 fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  8000 N (Δα reversible, IEC 60794-1-2-E1)
Nominal span :  160m
Maximumspan :  280m
Crush :  3000N/100mm (Δα reversible, IEC 60794-1-2-E3)

Impact :  15J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

 

Colour code of tubes and fibers

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Blue Orange Green Brown Grey White (natural) Red Black Yellow Violet Pink Aqua
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Fillers Black or Grey

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Nominal O.D. (mm) Weight (kg/km) Packaging
2 MT8002xxMSPoo 1 2 5 14.0 145 Drum (2 or 4km)
4 MT8004xxMSPoo 1 4 5 14.0 145 Drum (2 or 4km)
8 MT8008xxMSPoo 1 8 5 14.0 145 Drum (2 or 4km)
12 MT80121xxMSPoo 1 12 5 14.0 145 Drum (2 or 4km)
12 MT80122xxMSPoo 2 6 4 14.0 145 Drum (2 or 4km)
24 MT8024xxMSPoo 2 12 4 14.0 145 Drum (2 or 4km)
48 MT8048xxMSPoo 4 12 2 14.0 145 Drum (2 or 4km)
72 MT8072xxMSPoo 6 12 0 14.0 145 Drum (2 or 4km)

xx = fiber type                  ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         ex. 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access Duct Dielectric cable type UDD2 up to 24 cores, single tube

    
*All images are indicative

 

Features

Small diameter and very light weight
All Dielectric Non-Metallic design
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication, MAN, WAN
FTTx backbone and access
Interconnection of distribution boxes, frames and panels at customer’s side

 

Installation Features

Store at  -40 to +70 °C
Install at  -30 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -30 to +70 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with thixotropic jelly (typical diam. 2.8mm)
Strength elements :  2 x FRP rods inside the outer jacket
Peripheral elements :  glass yarns with ripcord
Outer jacket :
  Black HDPE material UV-Resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable UDD2 fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension in installation :  700N (Δα reversible, IEC 60794-1-2-E1)
Pulling tension in operation :  200N (Δα reversible, IEC 60794-1-2-E1)
Crush :  200N/100mm, max 15 min. (Δα reversible, IEC 60794-1-2-E3)

Impact :  1Nm, 3 impacts, R=300mm (Δα reversible, IEC 60794-1-2-E4)
Torsion :  1m, 100N, +/-180°, 10 cycles (Δα reversible, IEC 60794-1-2-E7)
Repeated bending :  R=20xOD, 100N, 35 cycles (Δα reversible, IEC 60794-1-2-E6)
Bending radius :  R=20xOD, 4 turns, 3 cycles (Δα reversible, IEC 60794-1-2-E11)
Temperature cycling :  -40°C to +70°C, (Δα reversible, IEC 60794-1-2-F1)

Water penetration :  3m cable, 1m water, 24 hours (no leakage, IEC 60794-1-2-F5B)

 

 

Colour code of tubes and fibers

                         
Tube 1
Natural
Fibers Option 1 1×24
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/black Orange/black Green/Black Brown/black Grey/black White/black Red/black Natural Yellow/black Violet/black Pink/black Aqua/black
Fibers Option 2 2×12
Bundle A 1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Bundle B 13 14 15 16 17 18 19 20 21 22 23 24
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Nominal O.D. (mm) Weight (kg/km) Packaging
2 (option 1) UDD21 02 xx Eoo 1 2 0 7.2 42 Drum (2 or 4km)
4 (option 1) UDD21 04 xx Eoo 1 4 0 7.2 42 Drum (2 or 4km)
8 (option 1) UDD21 08 xx Eoo 1 8 0 7.2 42 Drum (2 or 4km)
12 (option 1) UDD21 12 xx Eoo 1 12 0 7.2 42 Drum (2 or 4km)
24 (option 1) UDD21 24 xx Eoo 1 24 0 7.2 42 Drum (2 or 4km)
2 (option 2) UDD22 02 xx Eoo 1 2 0 7.2 42 Drum (2 or 4km)
4 (option 2) UDD22 04 xx Eoo 1 4 0 7.2 42 Drum (2 or 4km)
8 (option 2) UDD22 08 xx Eoo 1 8 0 7.2 42 Drum (2 or 4km)
12 (option 2) UDD22 12 xx Eoo 1 12 0 7.2 42 Drum (2 or 4km)
24 (option 2) UDD22 24 xx Eoo 1 24 0 7.2 42 Drum (2 or 4km)

xx = fiber type                  ex. OS2=S2, G657A1= 71, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         ex. 2000m=D2, 4000m=D4 (tolerance ±5%)

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access Duct Metallic cable type UDD2 up to 24 cores, single tube

    
*All images are indicative

 

Features

Small diameter and very light weight
Metallic strength members
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication, MAN, WAN
FTTx backbone and access
Interconnection of distribution boxes, frames and panels at customer’s side

 

Installation Features

Store at  -40 to +70 °C
Install at  -30 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -30 to +70 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with thixotropic jelly (typical diam. 2.8mm)
Strength elements :  2 x steel rods inside the outer jacket
Peripheral elements :  glass yarns with ripcord
Outer jacket :
  Black HDPE material UV-Resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable UDM2 fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension in installation :  100N (Δα reversible, IEC 60794-1-2-E1)
Pulling tension in operation :  400N (Δα reversible, IEC 60794-1-2-E1)
Crush :  200N/100mm, max 15 min. (Δα reversible, IEC 60794-1-2-E3)

Impact :  1Nm, 3 impacts, R=300mm (Δα reversible, IEC 60794-1-2-E4)
Torsion :  1m, 100N, +/-180°, 10 cycles (Δα reversible, IEC 60794-1-2-E7)
Repeated bending :  R=20xOD, 100N, 35 cycles (Δα reversible, IEC 60794-1-2-E6)
Bending radius :  R=20xOD, 4 turns, 3 cycles (Δα reversible, IEC 60794-1-2-E11)
Temperature cycling :  -40°C to +70°C, (Δα reversible, IEC 60794-1-2-F1)

Water penetration :  3m cable, 1m water, 24 hours (no leakage, IEC 60794-1-2-F5B)

 

 

Colour code of tubes and fibers

                         
Tube 1
Natural
Fibers Option 1 1×24
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/black Orange/black Green/Black Brown/black Grey/black White/black Red/black Natural Yellow/black Violet/black Pink/black Aqua/black
Fibers Option 2 2×12
Bundle A 1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Bundle B 13 14 15 16 17 18 19 20 21 22 23 24
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Nominal O.D. (mm) Weight (kg/km) Packaging
2 (option 1) UDM21 02 xx Eoo 1 2 0 7.2 42 Drum (2 or 4km)
4 (option 1) UDM21 04 xx Eoo 1 4 0 7.2 42 Drum (2 or 4km)
8 (option 1) UDM21 08 xx Eoo 1 8 0 7.2 42 Drum (2 or 4km)
12 (option 1) UDM21 12 xx Eoo 1 12 0 7.2 42 Drum (2 or 4km)
24 (option 1) UDM21 24 xx Eoo 1 24 0 7.2 42 Drum (2 or 4km)
2 (option 2) UDM22 02 xx Eoo 1 2 0 7.2 42 Drum (2 or 4km)
4 (option 2) UDM22 04 xx Eoo 1 4 0 7.2 42 Drum (2 or 4km)
8 (option 2) UDM22 08 xx Eoo 1 8 0 7.2 42 Drum (2 or 4km)
12 (option 2) UDM22 12 xx Eoo 1 12 0 7.2 42 Drum (2 or 4km)
24 (option 2) UDM22 24 xx Eoo 1 24 0 7.2 42 Drum (2 or 4km)

xx = fiber type                  ex. OS2=S2, G657A1= 71, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         ex. 2000m=D2, 4000m=D4 (tolerance ±5%)

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access microcable HBBX 24-288 cores, multi tube

    
*All images are indicative

 

Features

Small diameter and light weight
Air-blown installation
All Dielectric Non-Metallic design
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication, MAN, WAN
FTTx backbone and access

 

Installation Features

Store at  -40 to +70 °C
Install at  -30 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -30 to +60 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with thixotropic jelly 
Central element :  non-metallic FRP rod, nominal Ø 1.65mm
Ripcord :  1 yarn

Outer jacket :
  Black HDPE material UV-Resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable HBBX fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension in installation :  650N >96cores, 1000N >96<144 cores (Δα reversible, IEC 60794-1-2-E1)
Pulling tension in operation :  200N (Δα reversible, IEC 60794-1-2-E1)
Crush :  700N/100mm, max 15 min. (Δα reversible, IEC 60794-1-2-E3)

Impact :  1Nm, 3 impacts, R=300mm (Δα reversible, IEC 60794-1-2-E4)
Torsion :  1m, 100N, +/-180°, 10 cycles (Δα reversible, IEC 60794-1-2-E7)
Repeated bending :  R=20xOD, 100N, 35 cycles (Δα reversible, IEC 60794-1-2-E6)
Bending radius :  R=20xOD, 4 turns, 3 cycles (Δα reversible, IEC 60794-1-2-E11)
Temperature cycling :  -40°C to +70°C, (Δα reversible, IEC 60794-1-2-F1)

Water penetration :  3m cable, 1m water, 24 hours (no leakage, IEC 60794-1-2-F5B)

 

 

Colour code of tubes and fibers

                               
Tube layer 1 1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua
Tube layer 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua Blue Orange Green
Fibers 1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Slate White Red Black Yellow Violet Rose Aqua
Fibers 13 14 15 16 17 18 19 20 21 22 23 24
Blue/black Orange/black Green/black Brown/black Slate/black White/black Red/black Natural Yellow/black Violet/black Rose/black Aqua/black

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Tube diameter Nominal O.D. (mm) Weight (kg/km) Packaging
12 HBBX 012 xx E oo 1 12 5 1.6 6.0 31 Drum (2 or 4km)
24 HBBX 024 xx E oo 2 12 4 1.6 6.0 31 Drum (2 or 4km)
36 HBBX 036 xx E oo 3 12 3 1.6 6.0 31 Drum (2 or 4km)
48 HBBX 048 xx E oo 4 12 2 1.6 6.0 31 Drum (2 or 4km)
60 HBBX 060 xx E oo 5 12 1 1.6 6.0 31 Drum (2 or 4km)
72 HBBX 072 xx E oo 6 12 0 1.6 6.0 31 Drum (2 or 4km)
96 HBBX 096 xx E oo 8 12 0 1.6 7.2 38 Drum (2 or 4km)
120 HBBX 120 xx E oo 10 12 0 1.6 8.3 49 Drum (2 or 4km)
144 HBBX 144 xx E oo 12 12 0 1.6 8.3 50 Drum (2 or 4km)
192 HBBX 192 xx E oo 8 24 0 2.3 9.8 68 Drum (2 or 4km)
288 HBBX 288 xx E oo 12 24 0 2.3 13.0 119 Drum (2 or 4km)

xx = fiber type
ex. OS2=S2, G657A1 = A1, G657B1 = B1, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5

oo = delivery length        
ex. 2000m=D2, 4000m=D4 (tolerance ±5%)

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access microcable VBBX 2-24 cores, single tube

    
*All images are indicative

 

Features

Very small diameter and very light weight
Air-blown installation
All Dielectric Non-Metallic design
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication, MAN, WAN
FTTx backbone and access

 

Installation Features

Store at  -40 to +70 °C
Install at  -30 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -30 to +60 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with thixotropic jelly (typical diam. 2.8mm)
Peripheral element :  aramide yarns with ripcord
Outer jacket :
  Black HDPE material UV-Resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable VBBX fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension in installation :  650N (Δα reversible, IEC 60794-1-2-E1)
Pulling tension in operation :  200N (Δα reversible, IEC 60794-1-2-E1)
Crush :  200N/100mm, max 15 min. (Δα reversible, IEC 60794-1-2-E3)

Impact :  1Nm, 3 impacts, R=300mm (Δα reversible, IEC 60794-1-2-E4)
Torsion :  1m, 100N, +/-180°, 10 cycles (Δα reversible, IEC 60794-1-2-E7)
Repeated bending :  R=20xOD, 100N, 35 cycles (Δα reversible, IEC 60794-1-2-E6)
Bending radius :  R=20xOD, 4 turns, 3 cycles (Δα reversible, IEC 60794-1-2-E11)
Temperature cycling :  -40°C to +70°C, (Δα reversible, IEC 60794-1-2-F1)

Water penetration :  3m cable, 1m water, 24 hours (no leakage, IEC 60794-1-2-F5B)

 

 

Colour code of tubes and fibers

                         
Tube 1
Natural
Fibers Option 1 1×24
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/black Orange/black Green/Black Brown/black Grey/black White/black Red/black Natural Yellow/black Violet/black Pink/black Aqua/black
Fibers Option 2 2×12
Bundle A 1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Bundle B 13 14 15 16 17 18 19 20 21 22 23 24
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Nominal O.D. (mm) Weight (kg/km) Packaging
2 (option 1) VBBX1 02 xx Eoo 1 2 0 3.8 13 Drum (2 or 4km)
4 (option 1) VBBX1 04 xx Eoo 1 4 0 3.8 13 Drum (2 or 4km)
8 (option 1) VBBX1 08 xx Eoo 1 8 0 3.8 13 Drum (2 or 4km)
12 (option 1) VBBX1 12 xx Eoo 1 12 0 3.8 13 Drum (2 or 4km)
24 (option 1) VBBX1 24 xx Eoo 1 24 0 4.8 20 Drum (2 or 4km)
2 (option 2) VBBX2 02 xx Eoo 1 2 0 3.8 13 Drum (2 or 4km)
4 (option 2) VBBX2 04 xx Eoo 1 4 0 3.8 13 Drum (2 or 4km)
8 (option 2) VBBX2 08 xx Eoo 1 8 0 3.8 13 Drum (2 or 4km)
12 (option 2) VBBX2 12 xx Eoo 1 12 0 3.8 13 Drum (2 or 4km)
24 (option 2) VBBX2 24 xx Eoo 1 24 0 4.8 20 Drum (2 or 4km)

xx = fiber type                  ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         ex. 2000m=D2, 4000m=D4 (tolerance ±5%)

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable ADSS 2-72 cores, Short Span

    
*All images are indicative

 

Features

Aerial installation on HT power lines
All Dielectric Non-Metallic design
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -40 to +70 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with jelly (nominal dial. 2.5 ± 0.1mm)
Central member :  FRP (nominal diameter 2.0mm).
Assembling :  tubes and fillers assembled together according to “Colour Code” table
Wrapping :  water blocking tape.
Peripheral element :  aramide yarns with ripcord.
Outer jacket :  Black HDPE material, UV resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable ADSS MT30 fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  3000 N (Δα reversible, IEC 60794-1-2-E1)
Nominal span :  80m
Maximumspan :  120m
Crush :  2000N/100mm (Δα reversible, IEC 60794-1-2-E3)

Impact :  10J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

 

Colour code of tubes and fibers

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Blue Orange Green Brown Grey White (natural) Red Black Yellow Violet Pink Aqua
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Fillers Black or Grey

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Nominal O.D. (mm) Weight (kg/km) Packaging
2 MT3002xxASPoo 1 2 5 11.0 110 Drum
4 MT3004xxASPoo 1 4 5 11.0 110 Drum
8 MT3008xxASPoo 1 8 5 11.0 110 Drum
12 MT30121xxASPoo 1 12 5 11.0 110 Drum
12 MT30122xxASPoo 2 6 4 11.0 110 Drum
24 MT3024xxASPoo 2 12 4 11.0 110 Drum
48 MT3048xxASPoo 4 12 2 11.0 110 Drum
72 MT3072xxASPoo 6 12 0 11.0 110 Drum

xx = fiber type                  ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         ex. 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable MTE 2-48 cores, Outdoor, 1500N

  
*All images are indicative

Features

Outdoor and duct installation
All Dielectric Non-Metallic design
Light weight

 

Standards of reference and applications

IEC 60793, IEC 60794
Intrabuilding Voice and Data/LAN Communication Networks
Installation in Ducts & Conduits
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at  -5 to +50 °C
Operate at  -40 to +60 °C
Bend minimum  20 times O.D. (installation)
Bend minimum  15 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly (nominal diameter 2.3mm).
Central member : FRP (nominal diameter 2.0mm).
Assembling : tubes and fillers assembled together according to “Colour Code” table
Wrapping :  water blocking tape.
Protection :  anti-rodent glass yarns.
Outer jacket : Black HDPE material, UV resistant (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – Fiber Optic Cable MTE fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  1500 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  2000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  10J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of tubes and fibers

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Blue Orange Green Brown Grey White (natural) Red Black Yellow Violet Pink Aqua
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Fillers Black or Grey

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers O.D. (mm) Weight (kg/km) Packaging          
2 MTE1502xxoo 1 2 5 11.5 60 Drum
4 MTE1504xxoo 1 4 5 11.5 60 Drum
8 MTE1508xxoo 1 8 5 11.5 60 Drum
12 MTE1512xxoo 1 12 5 11.5 60 Drum
24 MTE15243xxoo 3 8 3 11.5 60 Drum
24 MTE15242xxoo 2 12 4 11.5 60 Drum
48 MTE1548xxoo 4 12 2 11.5 60 Drum

xx = fiber type                  ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         ex. 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable MTE 24-144 cores, Outdoor, 4000N

*All images are indicative
  

Features

Outdoor and duct installation
All Dielectric Non-Metallic design
Light weight

 

Standards of reference and applications

IEC 60793, IEC 60794
Intrabuilding Voice and Data/LAN Communication Networks
Installation in Ducts & Conduits
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at  -5 to +50 °C, Bend minimum  20 times O.D. 
Operate at  -40 to +70 °C, Bend minimum  10 times O.D. 

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly (nominal diameter 2.0mm).
Central member : FRP (nominal diameter 2.5mm).
Assembling : tubes and fillers assembled together according to “Colour Code” table
Wrapping :  water blocking tape.
Protection :  anti-rodent glass yarns.
Rip cord :  under the outer jacket.

Outer jacket : Black HDPE material, UV resistant (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – Fiber Optic Cable  MTE40  fiber count x fiber type – P/N – lot + meter

 

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  4000 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  2000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  3J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of tubes and fibers

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Blue Orange Green Brown Grey White (natural) Red Black Yellow Violet Pink Aqua
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Fillers Black or Grey

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers O.D. (mm) Weight (kg/km) Packaging
24 MTE4024xxoo 2 12 4 9.5 95 Drum
48 MTE4048xxoo 4 12 2 9.5 95 Drum
72 MTE4072xxoo 6 12 0 12.0 130 Drum
96 MTE4096xxoo 8 12 0 12.0 130 Drum
144 MTE40A4xxoo 12 12 0 12.0 130 Drum

xx = fiber type                  ex. OS2=S2, G657A1 = A1, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         ex. 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable UT9H 2-24 cores, Outdoor, 1500N

  
*All images are indicative
Features

Outdoor and duct installation
Metallic armour and moisture barrier
Compact and light weight

 

Standards of reference and applications

IEC 60793, IEC 60794
Intrabuilding Voice and Data/LAN Communication Networks
Installation in Ducts & Conduits
Building access in FTTx networks

 

Installation Features

Store at  -30 to +70 °C
Install at  -5 to +50 °C, Bend minimum 20 times O.D. (installation)
Operate at  -45 to +60 °CBend minimum 15 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly (nominal diameter 2.3mm).
Protection :  anti-rodent glass yarns.
Armour:  corrugated steel tape.
Outer jacket : Black LSZH material, UV resistant 
Marking : APS Finland – ww/yy – Armoured Fiber Optic Cable UT9H fiber count x fiber type – P/N – lot + meter

 

Environmental properties

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas :
IEC 60754-1, IEC 60754-2
Smoke Emission :
IEC 61034-2, EN 50268-2
Toxicity of evolved gas :
EN 50305 9.2
Flame retardant : 
IEC 60332-1-2

Fire retardant : IEC 60332-3-24 Cat.C
UV resistant :
 UL1581, IEC11801

 

Mechanical properties

Pulling tension :  1500 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  1000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  10J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

1 2 3 4 5 6 7 8 9 10 11 12
Bundle A Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Bundle B Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Nominal O.D. (mm) Weight (kg/km) Packaging
2 UT9H02xxoo 1 2 8.5 85 Drum
4 UT9H04xxoo 1 4 8.5 85 Drum
8 UT9H08xxoo 1 8 8.5 85 Drum
12 UT9H12xxoo 1 12 8.5 85 Drum
24 UT9H24xxoo 1 24 8.5 85 Drum

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         2000m=D2

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable UTAE 2-24 cores, Direct Burial, SWA Armoured

  
*All images are indicative
Features

Outdoor, duct and direct burial installation
Metallic armour and moisture barrier
Compact and light weight

 

Standards of reference and applications

IEC 60793, IEC 60794
Telecommunication backabones
Intrabuilding Voice and Data/LAN Communication Networks

Installation in Ducts & Conduits or Directly Buried
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at -10 to +60 °C, Bend minimum 20 times O.D. (installation)
Operate at  -40 to +70 °CBend minimum 10 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly (nominal diameter 3.0mm).
Inner strength member :  aramide yarns.
Inner jacket :  PE black, nominal thickness 1.0mm.

Armour:  steel wire, one layer, coverage ≥80%.
Outer jacket : PE black, UV resistant, nominal thickness 1.5mm.
Marking : APS Finland – ww/yy – Armoured Fiber Optic Cable UTAE fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  max 5000 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  3000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  15J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/black Orange/black Green/black Brown/black Grey/black White/black Red/black Natural Yellow/black Violet/black Pink/black Aqua/black

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Nominal O.D. (mm) Weight (kg/km) Packaging (*)
2 UTAE02xxoo 1 2 10.3 178 Drum
4 UTAE04xxoo 1 4 10.3 178 Drum
8 UTAE08xxoo 1 8 10.3 178 Drum
12 UTAE12xxoo 1 12 10.3 178 Drum
24 UTAE24xxoo 1 24 10.3 178 Drum

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         2000m=D2
(*) a tolerance of ±5% applies to the delivery length.               

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access DROP cable BOWA 1-4 cores, self-supporting

    
*All images are indicative

 

Features

Aerial installation (F8 type)
All Dielectric Non-Metallic design
LSZH Fire Retardant
Suitable for both indoor and outdoor
UV-Resistant outer jacket
Small size
100% dry design
Low installation cost
Easy to strip
Direct Connection to Terminal Equıpments

 

Standards of reference and applications

EN 50173-1, IEC 60754-2, IEC 60794-1&2, IEC 60793-1&2, IEC 60332-1 & 2
FTTH Applications

Aerial (F8 Type with Steel Messenger Wire) 
Drop Cabling
Intrabuilding Voice or Data Communication Networks
Outdoor Interconnect and Patchcord Applications
Interconnection of Distribution Boxes, Distribution Frames and Customer Equipment and between the buildings
WAN
Aerial (Lashed)

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +60 °C
Operate at  -40 to +70 °C 

 

Design

Optical fiber :  1 to 4 cores 125/250μm, Single Mode or Multi Mode
Outer jacket :  Black LSZH-HFFR material

Self supporting element :  FRP rod 1.0mm
Peripheral pulling elements : 
FRP rod 0.5mm
Marking :  APS Finland – ww/yy – DROP Fiber Optic Cable BOWA fiber count x fiber type – P/N – lot + meter

 

Environmental properties

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness :
TS EN 50267-2-3
Smoke Emission :
IEC 61034-2
Flame retardant : 
IEC 60332-1-1, IEC60332-2-1
UV resistant :
 UL1581, IEC11801

 

Mechanical properties

Bending radius : 15 x O.D. (OS2 and MM), 10 x O.D. (G657A1/2)
Pulling tension, during installation :
  600 N
Pulling tension, permanent :  400 N
Crush :  600N/100mm (IEC 60794-1-2 E3)
Impact :  5J (Δα reversible, IEC 60794-1-2-E4)

 

 

Colour code of fibers

  1 2 3 4
Fiber Colours Blue Orange Green Brown

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number Nominal O.D. (mm) Weight (kg/km) Packaging
1 DRBA1xxxoo 5.2 x 2.0 21 Drum (1 or 2km)
2 DRBA2xxxoo 5.2 x 2.0 12 Drum (1 or 2km)
4 DRBA4xxxoo 5.2 x 2.0 12 Drum (1 or 2km)

xx = fiber type                  ex. OS2=S2, G657a1=7A1, G657a2=7A2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=5
oo = delivery length         ex. 1000m=D1, 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIOVH OPGW Optical Ground Wire up to 24 cores type B1-63

 

*All images are indicative

Features
SUS AL tube
AA wire
Right Hand Z-stranding

 

Standards of reference and applications
IEC, IEEE, DL/T 832-2003, GB/T 7424.4-2003 standards

Installation Features

Store at  -40 to +60 °C
Install at  -10 to +50 °C, Bend minimum  262 mm
Operate at  -40 to +80 °C, Bend minimum  157 mm

 

Design

Optical fiber : 125/250μm Single Mode G652.D or G.655
Fiber Buffer : Central SUS Tube / AL-Tube diameter 3.0/5.2 mm
Layer 1 : 9 wires AS/AA diameter 2.65 mm

 

Mechanical properties

Supporting Cross Section :       63.8 mm2
Section of AS Wire :  49.6 mm2
Section of AL tube :  14.2 mm2
Ultimate Tensile Strength (UTS) :  56.8 kN
Rate Tensile Strength (RTS) :  51.6 kN
Modulus of Elasticity (E-Modulus) :  121.3 kN/mm2
Thermal Elongation Coefficient :  14.4 Å~10-6 /℃
Permissible Maximum Working Stress (40% RTS) :  323.7 N/mm2
Everyday Stress( EDS) (18%~25% RTS) :  145.7 ~202.3 N/mm2
Ultimate Exceptional Stress (70% RTS) :  566.5 N/mm2
DC Resistance :  0.789 Ω/km
Short Time Current (0.5s, 40℃ ~200℃ ) :  7.7 kA
Short Time Current Capacity I²t :  29.3 kA²s
Ratio between Pull and Weight :  14.8 km

 

Colour code of fibers

1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Rose Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/Black Orange/Black Green/Black Brown/Black Grey/Black White/Black Red/Black Natural Yellow/Black Violet/Black Rose/Black Aqua/Black

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number Central tube Fibers per tube 1st layer (no of tubes) O.D. (mm) Weight (kg/km) Packaging
2 OPGWB16302xx 1 2 9 10.5 357 2-4km
4 OPGWB16304xx 1 4 9 10.5 357 2-4km
8 OPGWB16308xx 1 8 9 10.5 357 2-4km
12 OPGWB16312xx 1 12 9 10.5 357 2-4km
24 OPGWB16324xx 1 24 9 10.5 357 2-4km

xx = fiber type                  ex. G652D=S2, G655=S5

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC Access Distribution Box up to 6 trays (12 fibers/tray)

Standards of reference and applications

  • Subscriber Access
  • Fiber-to-the-x
  • Telecommunication, WAN

 

Main Features

  • Dust-proof design, IP54 protection
  • Integrated splice cassette and cable/fiber management
  • Suitable for both fusion and mechanical splice
  • up to 6 trays (12/24 fibers per tray)
  • Designed for 20 years lifetime

Installation Features

Store at -0 to +70 °C
Install at -0 to +50 °C
Operate at -40 to +70 °C

 

Design and specifications

Material : plastic, flame retardant V0
Colour : black
Seal material (box) : EPDM
Seal material (ports) : Rubber
Protection rating : IP54

Entry ports and cable diameter (max) : 2 x 25mm rubber grommets
Output ports and cable diameter (max) : 5 x 15mm rubber grommets
Max no of splice trays : 6
Splice capacity of each tray :
12/24 fo
Type of adaptors: SC Simplex or LC Duplex
Max no of adaptors : 24 SC

Cover open fixed position : 90 and 180 degrees
Lock type : key lock with dust proof cover
Mount : wall or pole

Size : 245*296*94.5 mm
P/N : ADBIOWP61224S (w/o lock)
P/N : ADBIOWP61224L (w/o lock)

Locking mechanism

Opening mechanism

 

Trays specification

Part No. Splice tray SET612 PLC Splitter tray SRT
Dimensions 115x144x10mm 115x144x10mm
Material ABS ABS
Splice capacity 12/24 FO 6/12 FO
Suitable sleeve 40-45mm 40-45mm
Splice module Fixed Removable
Splitter type N/A Micro PLC Splitter
Bend radius ≥30mm ≥30mm
Plastic cover top tray only top tray only
Transparent cover all trays except the top one all trays except the top one

 

 

Recommended connectivity

Adaptors : all LIIN-25 adaptors SC and LC (UPC or APC), SM and MM
Pigtails : all LIIN-25 pigtails SC and LC (UPC or APC), SM and MM
Patchcords : all LIIN-25 patchcords SC and LC (UPC or APC), SM and MM

.

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC Access Terminal Box 2 and 4 Ways, SC / LC

Standards of reference and applications

  • LAN/SAN
  • CATV networks
  • Fiber-to-the-home (FTTH) applications

 

Main Features

  • Dust-proof design, IP45 protection
  • Integrated splice cassette and cable/fiber management
  • Suitable for both fusion and mechanical splice
  • Embedded surface with easy-to-remove cover
  • 2 and 4 ports models

Installation Features

Store at  -0 to +70 °C
Install at  -0 to +50 °C
Operate at  -40 to +85 °C

 

Design, 2 ports model

Material :  PC + ABS plastic
Colour :  white
Number of ports :  2
Type of adaptors:  SC Simplex or LC Duplex
Number of cores:  up to 2 (with SC adaptors) or 4 (with LC adaptors)
Mount :  wall type
Size :  86*86*27 mm
Weight:  0.2 kg
P/N :  FATB2SAE

 

 

Design, 4 ports model

Material :  PC + ABS plastic
Colour :  Grey
Number of ports :  4
Type of adaptors:  SC Simplex or LC Duplex
Number of cores:  up to 4 (with SC adaptors) or 8 (with LC adaptors)
Mount :  wall type
Size :  225*160*45 mm
Weight:  0.4 kg
P/N :  FATB4SAE

 

Recommended connectivity

Adaptors :  all LIIN-25 adaptors SC and LC (UPC or APC), SM and MM
Pigtails :   all LIIN-25 pigtails SC and LC (UPC or APC), SM and MM
Patchcords :  all LIIN-25 patchcords SC and LC (UPC or APC), SM and MM

.

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 24 Way SC Duplex / LC Quad Fibre Optic Panel – Empty

Standards of reference and applications

EIA19″
Data centers
LAN/SAN
CATV networks
Fiber-to-the-home (FTTH) applications

 

Installation Features

Store at  -0 to +70 °C
Install at  -0 to +50 °C
Operate at : -20 to +60 °C
Fitting : designed for 24 adapters (SC Simplex or LC Duplex)

 

Design

Material :  powder painted steel
Colour :  black
Features : built-in splice management
Number of adaptors:  24
Type of adaptors:  SC Duplex or LC Quad
Number of cores:  up to 48 with SC DX or up to 96 with LC QD
Size :  19″, 1 Unit / Width: 483mm x Height 44mm x Depth 205mm

 

Ordering and delivery information

P/N Weight (kg/km) Packaging
ODF124SCD 2.1 1 pc / ctn

 

Recommended connectivity

Adaptors :  all LIIN-25 adaptors SC and LC, SM and MM
Pigtails :   all LIIN-25 pigtails SC and LC, SM and MM
Patchcords :  all LIIN-25 patchcords SC and LC, SM and MM

.

 

Extended System Warranty

The APS System Warranty assures the compliance of the system performance to the applicable class of cabling for a period of 25 years. The warranty may be applied for by an accredited APS Partner who has designed and/or installed the entire system.

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 24 Way SC Simplex / LC Duplex Fibre Optic Panel – Empty

Standards of reference and applications

EIA19″
Data centers
LAN/SAN
CATV networks
Fiber-to-the-home (FTTH) applications

 

Installation Features

Store at  -0 to +70 °C
Install at  -0 to +50 °C
Operate at : -20 to +60 °C
Fitting : designed for 24 adapters (SC Simplex or LC Duplex)

 

Design

Material :  powder painted steel
Colour :  black
Features : built-in splice management
Number of adaptors:  24
Type of adaptors:  SC Simplex or LC Duplex
Number of cores:  up to 24 with SC SX or up to 48 with LC DX
Size :  19″, 1 Unit / Width: 483mm x Height 44mm x Depth 205mm

 

Ordering and delivery information

P/N Weight (kg/km) Packaging
ODF124SCS 2.1 1 pc / ctn

 

Recommended connectivity

Adaptors :  all LIIN-25 adaptors SC and LC, SM and MM
Pigtails :   all LIIN-25 pigtails SC and LC, SM and MM
Patchcords :  all LIIN-25 patchcords SC and LC, SM and MM

.

 

Extended System Warranty

The APS System Warranty assures the compliance of the system performance to the applicable class of cabling for a period of 25 years. The warranty may be applied for by an accredited APS Partner who has designed and/or installed the entire system.

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 Adaptor LC Duplex and Quad

   

Features

  • Single Mode and Multi Mode
  • Test Certificate on each package
  • ISO9001, RoHS Compliant
  • Batch number tracking
  • Dust cover
  • 25 years system warranty

Standards of reference and applications

ITU.T G652.D, ISO/IEC 11801, EIA/TIA 568 B.3, IEC60874, IEC EN 61754-4, EN 61754-20, EN 61755-3-2, EN 61755-2-2/B, EN 61755-2-2/1, EN-50173-1
Telecommunication, LAN, FTTx Cabling, CCTV

 

Installation Features

Store at  +10 to +50 °C
Install at  0 to +50 °C
Operate at : -10 to +70 °C

 

Design

Material :  plastic
Connection A :  LC
Connection B :  LC
Fastening :  clip
SM UPC colour :  blue
SM APC colour :  green
MM UPC colour :  OM1 and OM2 = beige, OM3 = turquoise, OM4 = purple.

 

Fiber Optic characteristics

  MM SM PC SM UPC SM APC
Insertion Loss dB (typical) ≤ 0,2 ≤ 0,2 ≤ 0,2 ≤ 0,2
Return Loss dB (typical) ≥ 35 ≥ 45 ≥ 45 ≥ 55
Repeatability dB (typical) ≤ 0,2 ≤ 0,2 ≤ 0,2 ≤ 0,2
Changeability dB (typical) ≤ 0,2 ≤ 0,2 ≤ 0,2 ≤ 0,2

Ordering and delivery information

Fiber count P/N Packaging
Duplex UPC AD xxx LC U DX 25 pcs / box
Duplex APC AD xxx LC A DX 25 pcs / box
Quad UPC AD xxx LC U QD 25 pcs / box
Quad APC AD xxx LC A QD 25 pcs / box

xxx = fiber type = OS2, OM1, OM2, OM3, OM4.

Recommended connectivity

Cables : APS LIIN-25 series 
Patch cords : APS LIIN-25 series
Pigtails : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Extended System Warranty

The APS System Warranty assures the compliance of the system performance to the applicable class of cabling for a period of 25 years. The warranty may be applied for by an accredited APS Partner who has designed and/or installed the entire system.

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 Adaptor SC Simplex and Duplex

   

Features

  • Single Mode and Multi Mode
  • Test Certificate on each package
  • ISO9001, RoHS Compliant
  • Batch number tracking
  • Dust cover
  • 25 years system warranty

Standards of reference and applications

ITU.T G652.D, ISO/IEC 11801, EIA/TIA 568 B.3, IEC60874, IEC EN 61754-4, EN 61754-20, EN 61755-3-2, EN 61755-2-2/B, EN 61755-2-2/1, EN-50173-1
Telecommunication, LAN, FTTx Cabling, CCTV

 

Installation Features

Store at  +10 to +50 °C
Install at  0 to +50 °C
Operate at : -10 to +70 °C

 

Design

Material :  plastic
Connection A :  SC
Connection B :  SC
Fastening :  clip and screw
SM UPC colour :  blue
SM APC colour :  green
MM UPC colour :  beige

 

Fiber Optic characteristics

  MM SM PC SM UPC SM APC
Insertion Loss dB (typical) ≤ 0,2 ≤ 0,2 ≤ 0,2 ≤ 0,2
Return Loss dB (typical) ≥ 35 ≥ 45 ≥ 45 ≥ 55
Repeatability dB (typical) ≤ 0,2 ≤ 0,2 ≤ 0,2 ≤ 0,2
Changeability dB (typical) ≤ 0,2 ≤ 0,2 ≤ 0,2 ≤ 0,2

Ordering and delivery information

Fiber count P/N Packaging
Simplex UPC AD xxx SC U SX 25 pcs / box
Simplex APC AD xxx SC A SX 25 pcs / box
Duplex UPC AD xxx SC U DX 25 pcs / box
Duplex APC AD xxx SC A DX 25 pcs / box

xxx = fiber type = OS2, OM1, OM2, OM3, OM4.
oo = connector type = SC, LC, FC, ST.
a = U for UPC, A for APC
bb = SX, DX or QU (for QUAD)

Recommended connectivity

Cables : APS LIIN-25 series 
Patch cords : APS LIIN-25 series
Pigtails : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Extended System Warranty

The APS System Warranty assures the compliance of the system performance to the applicable class of cabling for a period of 25 years. The warranty may be applied for by an accredited APS Partner who has designed and/or installed the entire system.

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 Fiber Optic Preterminated cables

   

Features

70% faster to install
Very Low Installation Cost
No termination failures.
No waste of cables and connectors and termination materials.
Better attenuation values.
Pre-tested and test reports available for each single fiber.
Made after the customer’s requirements, tailored to the specific case.
Pulling socks, strength elements and protection tubes available.
Different cables design available
SC, LC, MU, ST, FC, MT-RJ, and MTP connectors available.
Halogen Free Fire Retardant / Low Smoke Zero Halogen available.

 

 

Maximise your project with the APS failure-free, installation-ready preterminated fiber optic cables.

APS designs and delivers factory terminated fiber optic cables for various projects, from the biggest data center to the smaller LAN or industrial networks, with no minimum quantity required. Cables are made from high quality components, according the latest editions of the applicable standards or customer’s requirements, with each single terminated fiber tested. The use of APS factory terminated cables minimizes the risks of the installation failures that might happen when terminating cables on site, due to the often non-optimal conditions at the site. Our pre terminated cables are available with both modular connectors than with MTP connectors and they are always done in accordance to the customer’s specification or requirements, to answer fully to the needs of each specific installation.

 

 

Prime quality and long lasting reliability 

The high standards of our manufacturing and testing processes ensure the installation will benefit from products of the highest quality. At APS we are very strict with the quality of our polishing process and with the compliance of each single terminated fiber with our own internal as well as with the applicable standards. In fact, we pay a lot of attention that the mechanical connections, the reflection coefficient, the attenuation values and the geometry of the connector’s head are up to the standards and requirements.
Tests are done in accordance with ISO standards. The geometry of the fiber is tested with interferometer.

 

 

The largest scope, tailored to you

APS is offering a range of options that are virtually covering all requirements and applications.
Our scope of supply includes both silica fiber SM (G652, G657, G655) and MM (50 and 62,5 OM1, OM2, OM3, OM4, OM5) than Plastic Fibers (POF) while the cable used are as much as possible tailored to the customers’ or project requirements, be for indoor, indoor/outdoor or outdoor applications.

Product configurator : for a faster response please download APS “Preterm Configurator”, fill it in with your requirements and email it to your sales representative.

 

 

 

Optical cables innovation

Always up to date with the latest trends and technologies, APS keeps designing optical fiber cables to meet the new challenges of the telecommunication and data industries. Being space and growing data traffic being these days the main issue others, we have designed cables like MCHF and MIFFE for the installation of high fiber counts in packed indoor environments like datacenters. These cables are available in range from 4 to 288 cores. These cables save significant amount of the space that cables are taking in the group of typical sisä- ulkocables. These valmiskaapelit can be used also for the teollisuus standard MPO (MTP®). This way we are making sure of the highest kuitutiheyden and joustavimman runkoverkon liitettävyyden ratkaisut datakeskuksiin ja lähiverkon asennuksiin.

 

 

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 FO Distribution cable TB FTMS 2-24 Universal

   

Features

Easy to Strip, Direct Termination
Non-Metallic Strength Members
Dry, All Dielectric Non-Metallic design
Halogen Free Fire Retardant / Low Smoke Zero Halogen
Flexible
Low Installation Cost

 

Standards of reference and applications

DIN VDE 0888 Part 6; IEC 61034; IEC 60332-1&2; IEC 60754-2; IEC 60794-1&2
Inter Building and Intrabuilding Voice and Data/LAN Communication Networks
Interconnection of Distribution Boxes, Distribution Frames and Customer Equipment and between the floors
Direct Connection to Terminal Equipments
Installation in Ducts & Conduits
Vertical Riser and General Horizontal Applications
FTTx Cabling

 

Installation Features

Store at  -5 to +50 °C
Install at  -0 to +50 °C
Operate at : -10 to +70 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : 900μm tight, colour coded (see table 1)
Cable core : 2 to 24 optical fibers
Protection : glass or aramide yarns
Outer jacket : fire retardant LSZH material, UV resistant
Marking : APS Finland – ww/yy – Fiber Optic Cable TB FTMS fiber count x fiber type – LSZH-FR UVR IEC60332-3-24 – /lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH arvo ≥ 4,3 ja sähkönjohtavuus ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 ( ≤ 0.3%)
Smoke Emission : IEC 61034-2, EN 50268-2 (≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
UV resistant : UL1581, IEC11801

 

Fiber Optic characteristics

See detailed specification of optical fibers.

Colour code of fibers

                       
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/Black Orange/Black Green/Black Brown/Black Grey/Black White/Black Red/Black Natural Yellow/Black Violet/Black Pink/Black Aqua/Black

Ordering and delivery information

Fiber count P/N O.D [mm] Pulling tension (perm/inst) Crush (N) Impact Weight (kg/km) Packaging
2 FTMS02xxc 4.5 400/600 1000 3J 26 2000m / 6561ft
4 FTMS04xxc 5.5 400/600 1000 3J 31 2000m / 6561ft
6 FTMS06xxc 6.0 600/1000 1000 5J 42 2000m / 6561ft
8 FTMS08xxc 6.8 600/1000 1000 5J 48 2000m / 6561ft
12 FTMS12xxc 7.2 800/1200 1000 5J 54 2000m / 6561ft
16 FTMS16xxc 8.0 1000/1600 1000 5J 67 2000m / 6561ft
24 FTMS24xxc 8.6 1200/2000 1000 5J 85 2000m / 6561ft

xx = fiber type        ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
c = colour               ex. White=W, Yellow=Y, Orange=O, Grey=G,Turquoise=T, Purple=P

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 FO Distribution cable TB FTMS 48-96 cores Universal

   

Features

Easy to Strip, Direct Termination
Non-Metallic Strength Members
Dry, All Dielectric Non-Metallic design
Halogen Free Fire Retardant / Low Smoke Zero Halogen
Flexible
Low Installation Cost

 

Standards of reference and applications

DIN VDE 0888 Part 6; IEC 61034; IEC 60332-1&2; IEC 60754-2; IEC 60794-1&2, EN 187000
Inter Building and Intrabuilding Voice and Data/LAN Communication Networks
Interconnection of Distribution Boxes, Distribution Frames and Customer Equipment and between the floors
Direct Connection to Terminal Equipments
Installation in Ducts & Conduits
Vertical Riser and General Horizontal Applications
FTTx Cabling

 

Installation Features

Store at  -5 to +50 °C
Install at  -0 to +50 °C, Bend minimum : 15 times O.D.
Operate at : -10 to +70 °C, Bend minimum : 12 times O.D.

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : 900μm tight, colour coded (see table 1)
Cable core : 12 or 24 optical fibers
Protection : glass or aramide yarns
Sub-unit jacket : fire retardant LSZH material, UV resistant
Marking : numbering 1 to 8
Assembling: from 4 up to 8 sub-units assembled together into a compact core
Wrapping: polyester tape
Outer jacket : fire retardant LSZH material, UV resistant (nominal thickness 1.2mm)
Marking : APS Finland – ww/yy – Fiber Optic Cable TB FTMS “fiber count and type” – LSZH IEC60332-3-24 Cat.C – lot no – meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH arvo ≥ 4,3 ja sähkönjohtavuus ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 ( ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
UV resistant : UL1581, IEC11801

 

Fiber Optic characteristics

See detailed specification of optical fibers.

Colour code of fibers

                       
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/Black Orange/Black Green/Black Brown/Black Grey/Black White/Black Red/Black Natural Yellow/Black Violet/Black Pink/Black Aqua/Black

Ordering and delivery information

Fiber count P/N O.D [mm]
Subcable
O.D [mm] Pulling tension (perm/inst) Crush (N) Impact Weight (kg/km) Packaging
48 FTMS48xxc 6.5 18.0 1500 1500 4J 350 500m / 1640ft
72 FTMS72xxc 6.5 22.0 1500 1500 4J 450 500m / 1640ft
96 (8×12) FTMS968xxc 6.5 22.0 1500 1500 4J 550 500m / 1640ft
96 (4×24) FTMS964xxc 8.6 21.0 1500 1500 4J 550 500m / 1640ft

xx = fiber type        ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
c = colour               ex. White=W, Yellow=Y, Orange=O, Grey=G,Turquoise=T, Purple=P

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 FO Pigtail LC

   

Features

  • G.652.D OS2 Single and Multi Mode
  • Simplex and duplex
  • ISO9001, RoHS Compliant
  • Test Certificate for each item
  • Batch number tracking

Standards of reference and applications

ITU.T G652.D, ISO/IEC 11801, EIA/TIA 568 B.3, IEC60874, IEC EN 61754-20, EN 61755-3-2, EN 61755-2-2/B, EN 61755-2-2/1
Telecommunication, LAN, FTTx Cabling, CCTV

 

Installation Features

Store at  +10 to +50 °C
Install at  0 to +50 °C and bend minimum : 20 times O.D.
Operate at : -10 to +70 °C and bend minimum : 10 times O.D.
Short term max. pulling tension :  6.0N
Long term max. pulling tension :  3.0N

 

Design

Optical fiber :  125/250 Single and Multi Mode
Buffer :  900μm tight, colour coded
Fiber count :  1
Outer diameter :  0.9mm
UPC connector colour :  blue
APC connector colour :  green
Assembly :  glue and polish
Connection :  physical contact

 

Fiber Optic characteristics

  MM SM PC SM UPC SM APC
Insertion Loss dB (typical) 0.15 0.15 0.15 0.15
Return Loss dB (typical) ≥ 35 ≥ 45 > 50 > 60
Repeatability dB (typical) ≤0,2 ≤0,2 ≤0,2 ≤0,2
Changeability dB (typical) ≤0,2 ≤0,2 ≤0,2 ≤0,2

Colour code of fibers

                       
1 2 3 4 5 6 7 8 9 10 11 12
Light Green Pink Purple Yellow Black Red White Grey Brown Green Orange Blue

Ordering and delivery information

Fiber count P/N Weight (kg/km) Length (m) Packaging
1 PT xxx LC a 02 0.9 2.0 12 pcs / ctn
1 PT xxx LC a 00 0.9 custom custom

oo =connector type = SC, LC, FC, ST
a = U for UPC, A for APC
oo =connector type = SC, LC, FC,
ST 00 = length (standard 2.0mm)

Recommended connectivity

Cables : APS LIIN-25 series 
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Extended System Warranty

The APS System Warranty assures the compliance of the system performance to the applicable class of cabling for a period of 25 years. The warranty may be applied for by an accredited APS Partner who has designed and/or installed the entire system.

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.