AIAI up to 24 fibers, tight buffered, armoured dielectric, SHF1, Fire Retardant IEC60332-3-22 Cat.A

    

 

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 15 times : O.D.
Operate at : -30 to +70 °CBend minimum : 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 25J

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : See table
Cable core : up to 24 tight buffered fibers are stranded together. The core is filled with waterblocking glass yarns.
Inner sheath : black SHF1 material
Armour : antirodent glass yarns. Coverage ≥80%.
Outer jacket : black SHF1 UV-Resistant material, LSZH
Marking : APS Finland ww/mm – Fiber Optic Cable AIAI “fiber count and type” – SHF1 IEC60332-3-22 Cat A – TK/lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Ordering and delivery information

Fiber count SM OM1 OM2 OM3 OM4 Packaging
2 OAIAI02S21 OAIAI02M11 OAIAI02M21 OAIAI02M31 OAIAI02M41 drum 2000m (+/-5%)
4 OAIAI04S21 OAIAI04M11 OAIAI04M21 OAIAI04M31 OAIAI04M41 drum 2000m (+/-5%)
8 OAIAI08S21 OAIAI08M11 OAIAI08M21 OAIAI08M31 OAIAI08M41 drum 2000m (+/-5%)
12 OAIAI12S21 OAIAI12M11 OAIAI12M21 OAIAI12M31 OAIAI12M41 drum 2000m (+/-5%)
24 OAIAI24S21 OAIAI24M11 OAIAI24M21 OAIAI24M31 OAIAI24M41 drum 2000m (+/-5%)

 

 

Colour code of fibers

Tube 2 fibers 4 fibers 8 fibers 12 fibers 24 fibers 48 fibers
1 Red (2 fibers) Red (2 fibers) Red (4 fibers) Red (4 fibers) Red (6 fibers) Red (12 fibers)
2 Filler Green (2 fibers) Green (4 fibers) Green (4 fibers) Green (6 fibers) Green (12 fibers)
3 Filler Filler Filler Natural (4 fibers) Natural (6 fibers) Natural (12 fibers)
4 Filler Filler Filler Filler Natural (6 fibers) Natural (12 fibers)
5 Filler Filler Filler Filler Filler Filler
6 Filler Filler Filler Filler Filler Filler

 

 

Features

Fiber count Inner jacket thickness (mm) Inner jacket diameter (mm) Outer jacket thickness (mm) Cable Diameter (mm) Cable weight (kg/km) Pulling tension (N)
2 1.0 4.8 1.0 8.0 95 1000
4 1.0 5.2 1.0 8.5 105 1000
8 1.0 6.0 1.0 9.4 125 1000
12 1.2 6.7 1.3 10.3 145 1500
24 1.2 8.5 1.3 12.1 185 2000

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


AICB up to 24 fibers tight buffered armoured SHF2 MUD NEK606, Fire Retardant IEC60332-3-22 Cat.A

    

 

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 15 times O.D.
Operate at : -30 to +70 °CBend minimum : 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 25J

 

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : See table
Cable core : up to 24 tight buffered fibers are stranded together. The core is filled with waterblocking glass yarns.
Inner sheath : black SHF1 material
Armour : galvanized steel, bronze or tinnerd copper wired braid. Coverage ≥80%.
Outer jacket : black MUD Resistant SHF2 material, UV-Resistant, LSZH
Marking : APS Finland – ww/mm – Fiber Optic Cable AICB “fiber count and type” – SHF1 IEC60332-3-22 Cat A – TK/lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

 

Ordering and delivery information

Fiber count SM OM1 OM2 OM3 OM4 Packaging
2 OAICB02S21 OAICB02M11 OAICB02M21 OAICB02M31 OAICB02M41 drum 2000m (+/-5%)
4 OAICB04S21 OAICB04M11 OAICB04M21 OAICB04M31 OAICB04M41 drum 2000m (+/-5%)
8 OAICB08S21 OAICB08M11 OAICB08M21 OAICB08M31 OAICB08M41 drum 2000m (+/-5%)
12 OAICB12S21 OAICB12M11 OAICB12M21 OAICB12M31 OAICB12M41 drum 2000m (+/-5%)
24 OAICB24S21 OAICB24M11 OAICB24M21 OAICB24M31 OAICB24M41 drum 2000m (+/-5%)

Note : for bronze braid add “B” at the end of the P/N, for tinned copper braid add “T” at the end of the P/N.

 

Colour code of fibers

01 02 03 04 05 06 07 08 09 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Turquoise
13 14 15 16 17 18 19 20 21 22 23 24
Blue/BR Orange/BR Green/BR Brown/BR Grey/BR White/BR Red/BR Black/BR Yellow/BR Violet/BR Pink/BR Turq./BR

 

 

Features

Fiber count Inner jacket thickness (mm) Inner jacket diameter (mm) Outer jacket thickness (mm) Cable Diameter (mm) Cable weight (kg/km) Pulling tension (N)
2 1.0 4.8 1.0 8.0 95 1000
4 1.0 5.2 1.0 8.5 105 1000
8 1.0 6.0 1.0 9.4 125 1000
12 1.2 6.7 1.3 10.3 145 1500
24 1.2 8.5 1.3 12.1 185 2000

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


AIWB up to 24 fibers tight buffered, SWA armoured SHF2 MUD NEK606, Fire Retardant IEC60332-3-22 Cat.A

   

 

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 15 times O.D.
Operate at : -30 to +70 °CBend minimum : 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 25J

 

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : See table
Cable core : up to 24 tight buffered fibers are stranded together. The core is filled with waterblocking glass yarns.
Inner sheath : black LSZH material
Armour : galvanized steel wires, concentrically applied. Coverage ≥80%.
Outer jacket : black LSZH MUD Resistant SHF2 material, UV-Resistant, abrasion and aliphatic hydrocarbon resistant
Marking : APS Finland – ww/mm – Fiber Optic Cable AIWB “fiber count and type” – LSZH-FR IEC60332-3-22 Cat A – TK/lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

 

Ordering and delivery information

Fiber count P/N Packaging
2 OAIWB02 ff drum 2000m (+/-5%)
4 OAIWB04 ff drum 2000m (+/-5%)
8 OAIWB08 ff drum 2000m (+/-5%)
12 OAIWB12 ff drum 2000m (+/-5%)
16 OAIWB16 ff drum 2000m (+/-5%)
24 OAIWB24 ff drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, ME for OM1+, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

Colour code of fibers

01 02 03 04 05 06 07 08 09 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Turquoise
13 14 15 16 17 18 19 20 21 22 23 24
Blue/BR Orange/BR Green/BR Brown/BR Grey/BR White/BR Red/BR Black/BR Yellow/BR Violet/BR Pink/BR Turq./BR

 

 

Features

Fiber count Inner jacket thickness (mm) Inner jacket diameter (mm) Outer jacket thickness (mm) Cable Diameter (mm) Cable weight (kg/km) Pulling tension (N)
2 1.0 4.8 1.0 10.0 125 1000
4 1.0 5.2 1.0 10.5 135 1000
8 1.0 6.0 1.0 11.4 155 1000
12 1.2 6.7 1.3 12.3 180 1500
16 1.2 7.5 1.3 13.2 210 2000
24 1.2 8.5 1.3 14.1 220 2000

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


AICI up to 24 fibers tight buffered, armoured metallic, LSZH, Fire Retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 15 times O.D.
Operate at : -30 to +70 °CBend minimum : 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 25J

 

 

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : See table
Cable core : up to 24 tight buffered fibers are stranded together. The core is filled with waterblocking glass yarns.
Inner sheath : black SHF1 material
Armour : galvanized steel, bronze or tinnerd copper wired braid. Coverage ≥80%.
Outer jacket : black SHF1 UV-Resistant material, LSZH
Marking : APS Finland – ww/mm – Fiber Optic Cable AICI “fiber count and type” – SHF1 IEC60332-3-22 Cat A – TK/lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber count SM OM1 OM2 OM3 OM4 Packaging
2 OAICI02S21 OAICI02M11 OAICI02M21 OAICI02M31 OAICI02M41 drum 2000m (+/-5%)
4 OAICI04S21 OAICI04M11 OAICI04M21 OAICI04M31 OAICI04M41 drum 2000m (+/-5%)
8 OAICI08S21 OAICI08M11 OAICI08M21 OAICI08M31 OAICI08M41 drum 2000m (+/-5%)
12 OAICI12S21 OAICI12M11 OAICI12M21 OAICI12M31 OAICI12M41 drum 2000m (+/-5%)
24 OAICI24S21 OAICI24M11 OAICI24M21 OAICI24M31 OAICI24M41 drum 2000m (+/-5%)

 

Colour code of fibers

01 02 03 04 05 06 07 08 09 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Turquoise
13 14 15 16 17 18 19 20 21 22 23 24
Blue/BR Orange/BR Green/BR Brown/BR Grey/BR White/BR Red/BR Black/BR Yellow/BR Violet/BR Pink/BR Turquoise/BR

 

Features

Fiber count Inner jacket thickness (mm) Inner jacket diameter (mm) Outer jacket thickness (mm) Cable Diameter (mm) Cable weight (kg/km) Pulling tension (N)
2 1.0 4.8 1.0 8.0 95 1000
4 1.0 5.2 1.0 8.5 105 1000
8 1.0 6.0 1.0 9.4 125 1000
12 1.2 6.7 1.3 10.3 145 1500
24 1.2 8.5 1.3 12.1 185 2000

 

 

Other standards of reference

 

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


BO1 fiber optic cable breakout SHF1

 

   

 

Store at: -40 to +70 °C
Install at: -10 to +50 °CBend minimum: 15 times O.D.
Operate at: -40 to +70 °CBend minimum:10 times O.D.
Crush maximum: 1000N/100mm
Impact maximum: 10J

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : white
Protection : aramide yarns
Inner sheath : blue SHF1 material, nominal diameter 2.0mm, each numbered for identification
Cable core : up to 24 tight buffered fibers are stranded together around a central member and wrapped by a synthetic tape.
Outer jacket : blue SHF1 UV-Resistant material, nominal thickness 1.2mm
Marking : APS Finland ww/mm – BO1 Fiber Optic Cable BREAKOUT “fiber count and type” – SHF1 IEC60332-3-22 Cat A – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Features

Fiber count Inner jacket thickness (mm) Inner jacket diameter (mm) Outer jacket thickness (mm) Cable Outer Diameter (mm) Cable weight (kg/km) Pulling tension (N)
2 0,5 2,0 1,2 7,5 70 500
4 0,5 2,0 1,2 8,5 75 1000
8 0,5 2,0 1,2 9,0 85 1000
12 0,5 2,0 1,2 10,0 110 1500
24 0,5 2,0 1,2 12,4 210 2000

Ordering and delivery information

Fiber count SM OM1 OM2 OM3 OM4 Packaging
2 OBO102S21 OBO102M11 OBO102M21 OBO102M31 OBO102M41 drum 2000m (+/-5%)
4 OBO104S21 OBO104M11 OBO104M21 OBO104M31 OBO104M41 drum 2000m (+/-5%)
8 OBO108S21 OBO108M11 OBO108M21 OBO108M31 OBO108M41 drum 2000m (+/-5%)
12 OBO112S21 OBO112M11 OBO112M21 OBO112M31 OBO112M41 drum 2000m (+/-5%)
24 OBO124S21 OBO124M11 OBO124M21 OBO124M31 OBO124M41 drum 2000m (+/-5%)

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


BOA1 fiber optic cable breakout armoured SHF1

 

   

 

Store at: -40 to +70 °C
Install at: -10 to +50 °CBend minimum: 15 times O.D.
Operate at: -40 to +70 °CBend minimum:10 times O.D.
Crush maximum: 2000N/100mm
Impact maximum: 20J

 

 

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : white
Protection : aramide yarns
Inner sheath : blue SHF1 material, nominal diameter 2.0mm, each numbered for identification
Cable core : up to 24 tight buffered fibers are stranded together around a central member and wrapped by a synthetic tape.
Intermediate jacket : blue SHF1 UV-Resistant material, nominal thickness 1.0mm
Armour : galvanized steel wire braid, coverage ≥85% (tinned copper or bronze braid available upon request)
Outer jacket : blue SHF1 UV-Resistant material, nominal thickness 1.2mm
Marking : APS Finland ww/mm – Fiber Optic Cable BREAKOUT BOA1 “fiber count / type” – ARMOURED SHF1 IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Features

Fiber count Simplex outer diameter (mm) Intermediate jacket diameter (mm) Outer jacket thickness (mm) Cable Outer Diameter (mm) Cable weight (kg/km) Pulling tension (N)
2 2,0 7,5 1,2 10,0 120 1000
4 2,0 8,5 1,2 11,0 180 2000
8 2,0 9,0 1,2 12,0 230 2000
12 2,0 10,0 1,2 12,5 360 2000
24 2,0 12,4 1,2 14,9 450 2500

 

 

Ordering and delivery information

Fiber count SM OM1 OM2 OM3 OM4 Packaging
2 OBOA102S21 OBOA102M11 OBOA102M21 OBOA102M31 OBOA102M41 drum 2000m (+/-5%)
4 OBOA104S21 OBOA104M11 OBOA104M21 OBOA104M31 OBOA104M41 drum 2000m (+/-5%)
8 OBOA108S21 OBOA108M11 OBOA108M21 OBOA108M31 OBOA108M41 drum 2000m (+/-5%)
12 OBOA112S21 OBOA112M11 OBOA112M21 OBOA112M31 OBOA112M41 drum 2000m (+/-5%)
24 OBOA124S21 OBOA124M11 OBOA124M21 OBOA124M31 OBOA124M41 drum 2000m (+/-5%)

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


BOXA1 fiber optic cable breakout armoured SHF1 Fire Resistant

   

 

 

Store at: -40 to +70 °C
Install at: -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 15 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 20J

 

 

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : white
Protection : aramide yarns
Inner sheath : Blue SHF1 material, nominal diameter 2.0mm, each numbered for identification (1 to 48)
Cable core : up to 48 single sheathed fibers are assembled together (around a central member if needed) and wrapped by a fire protection tape.
Overall protection : glass yarns
Intermediate jacket : Blue SHF1 UV-Resistant material, nominal thickness 1.0mm
Armour : galvanized steel wire braid, coverage ≥80%
Outer jacket : Blue SHF1 UV-Resistant material, nominal thickness 1.2mm
Marking : APS Finland ww/mm – ARMOURED Fiber Optic Cable BREAKOUT “fiber count / type” + “P/N” – SHF1 IEC60331-25 IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Oil resistant : intermittent splash – permanent resistance available upon request
Water absorption : IEC60502
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Features

Fiber count Simplex outer diameter (mm) Intermediate jacket diameter (mm) Outer jacket thickness (mm) Cable Outer Diameter (mm) Cable weight (kg/km) Pulling tension (N)
2 2,0 7,5 1,2 10,0 120 1000
4 2,0 8,5 1,2 11,0 180 2000
8 2,0 9,0 1,2 12,0 230 2000
12 2,0 10,0 1,2 12,5 360 2000
24 2,0 12,4 1,2 14,9 450 2500
36 2,0 16,4 1,2 20,0 670 2000
48 2,0 22,0 1,2 26,0 774 2500

Ordering and delivery information

Fiber count SM OM1 OM1+ OM2 OM3 OM4 Packaging
2 OBOXA102S21 OBOXA102M11 OBOXA102MP1 OBOXA102M21 OBOXA102M31 OBOXA102M41 2000m (+/-5%)
4 OBOXA104S21 OBOXA104M11 OBOXA104MP1 OBOXA104M21 OBOXA104M31 OBOXA104M41 2000m (+/-5%)
8 OBOXA108S21 OBOXA108M11 OBOXA108MP1 OBOXA108M21 OBOXA108M31 OBOXA108M41 2000m (+/-5%)
12 OBOXA112S21 OBOXA112M11 OBOXA112MP1 OBOXA112M21 OBOXA112M31 OBOXA112M41 2000m (+/-5%)
24 OBOXA124S21 OBOXA124M11 OBOXA124MP1 OBOXA124M21 OBOXA124M31 OBOXA124M41 2000m (+/-5%)
36 OBOXA136S21 OBOXA136M11 OBOXA136MP1 OBOXA136M21 OBOXA136M31 OBOXA136M41 2000m (+/-5%)
48 OBOXA148S21 OBOXA148M11 OBOXA148MP1 OBOXA148M21 OBOXA148M31 OBOXA148M41 2000m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable MTAH 2-72 cores, IN/OUT, SWA Armoured

  
*All images are indicative
Features

Outdoor, indoor and duct installation
Metallic armour
Low Smoke Zero Halogen

 

Standards of reference and applications

IEC 60793, IEC 60794
Telecommunication backabones
Intrabuilding Voice and Data/LAN Communication Networks

Installation in Ducts & Conduits 

 

Installation Features

Store at  -40 to +70 °C
Install at -10 to +60 °C, Bend minimum 20 times O.D. (installation)
Operate at  -40 to +70 °CBend minimum 15 times O.D. (static)

 

Design

Bare fiber : 250µm, SM or MM
Colour code : See table
Buffer : Loose tube (nom 1.9mm) filled with jelly, housing up to 12 fibers.
Colour code : See table
Central member : Thermoplastic resin coated single strand (FRP)
Cable core : Loose tubes and fillers (when necessary) assembled around the central member.
Wrapping :  water blocking tape.
Inner sheath : Black LSZH material.
Armour : single layer of galvanized steel wires. Coverage ≥80%.
Outer jacket : Black LSZH UV-Resistant material. Nominal outer diameter 14.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTAH “fiber count and type” – LSZH IEC60332-3-24 Cat.C – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2, EN 50268-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Mechanical properties

Pulling tension :  max 3000 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  3000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  30J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5), inner core only

 

Colour code

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Red Green Natural Natural Natural Natural
Fillers Black
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers O.D. (mm) Weight (kg/km) Packaging
2 MTAH3002 xx 1 2 5 14.5 280 Drum 2000m +/-5%
4 MTAH3004 xx 1 4 5 14.5 280 Drum 2000m +/-5%
8 MTAH3008 xx 1 8 5 14.5 280 Drum 2000m +/-5%
12 MTAH3012 xx 1 12 5 14.5 280 Drum 2000m +/-5%
24 MTAH3024 xx 2 12 4 14.5 280 Drum 2000m +/-5%
48 MTAH3048 xx 4 12 2 14.5 280 Drum 2000m +/-5%
72 MTAH3072 xx 6 12 0 14.5 280 Drum 2000m +/-5%

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
(*) a tolerance of ±5% applies to the delivery length.               

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


MTA1 Fire Resistant Double Armoured SHF1

   

 

 

 

Store at : -30 to +70 °C
Install at : – 5 to +50 °C, Bend minimum : 25 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 20 times O.D.
Pull maximum : 8000N
Crush maximum : 3000N/100mm
Impact maximum : 10J
Cable nominal weight : 590 kg/km
Cable elong. : 0.5%
Fibre elong. : 0.33%
Breaking load: 12 000 N

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø1.9mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Thermoplastic resin coated single strand
Cable core : Loose tubes and fillers (when necessary) assembled around the central member. The core is wrapped by a synthetic tape.
Inner sheath : Black LSZH material 1.0mm thick. Nominal diameter 9.0mm.
Armour : Double layer of galvanized steel wires. Coverage ≥80%.
Outer jacket : Black LSZH SHF1 material 1.5mm thick. Nominal outer diameter 15.7mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTA1 “fiber count and type” – SHF1 IEC60331-25 IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Oil resistant : intermittent splash – permanent resistance available upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Colour code of fibers

  01.  02.  03.  04.  05.  06.  07.  08.  09.  10.  11.  12. 
Natural  Red  Green  Yellow  Brown  Blue  Violet  Orange  Grey  White  Black  Pink 

 

 

Colour code of tubes

  Tube  4-12 fibers  24 fibers  36 fibers  48 fibers  72 fibers 
Red (4-12 fibers)  Red (12 fibers)  Red (12 fibers)  Red (12 fibers)  Red (12 fibers) 
Filler  Green (12 fibers)  Green (12 fibers)  Green (12 fibers)  Green (12 fibers) 
Filler  Filler  Natural (12 fibers)  Natural (12 fibers)  Natural (12 fibers) 
Filler  Filler  Filler  Natural (12 fibers)  Natural (12 fibers) 
Filler  Filler  Filler  Filler  Natural (12 fibers) 
Filler  Filler  Filler  Filler  Natural (12 fibers) 

Ordering and delivery information

  Fiber count  SM  OM1  OM1+  OM2  OM3  OM4  Packaging 
MTA104S2  MTA104M1  MTA104ME  MTA104M2  MTA104M3  MTA104M4  drum 2000m (+/-5%) 
MTA108S2  MTA108M1  MTA108ME  MTA108M2  MTA108M3  MTA108M4  drum 2000m (+/-5%) 
12  MTA112S2  MTA112M1  MTA112ME  MTA112M2  MTA112M3  MTA112M4  drum 2000m (+/-5%) 
24  MTA124S2  MTA124M1  MTA124ME  MTA124M2  MTA124M3  MTA124M4  drum 2000m (+/-5%) 
36  MTA136S2  MTA136M1  MTA136ME  MTA136M2  MTA136M3  MTA136M4  drum 2000m (+/-5%) 
48  MTA148S2  MTA148M1  MTA148ME  MTA148M2  MTA148M3  MTA148M4  drum 2000m (+/-5%) 
72  MTA172S2  MTA172M1  MTA172ME  MTA172M2  MTA172M3  MTA172M4  drum 2000m (+/-5%) 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 


MTFH Fire Resistant Single SWA Armoured LSZH

   

 

Features

Suitable for duct and underground installation
Rodent protected
Dry core
Waterproof
Fire resistant
Flame retardant
Halogen free and Low smoke emission
UV stabilized

 

Storage and handling 

Store at : -40 to +80 °C
Install at : -10 to +60 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +80 °C, Bend minimum : 10 times O.D.
Pull maximum : 2500N (installation), 800N (permanent)
Crush maximum : 3500N/100mm
Impact maximum : 10J
Cable nominal weight : 370 kg/km

 

Design

Bare fiber : 250µm
Colour code : See table
Buffer : Loose tube filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Thermoplastic resin coated single strand
Cable core : Loose tubes and fillers (when necessary) assembled around the central member.
Peripheral strength member : swellable glass yarns.
Wrapping :  water blocking tape.
Inner sheath : Black LSZH material.
Armour : single layer of galvanized steel wires. Coverage ≥80%.
Outer jacket : Black LSZH UV-Resistant material. Nominal outer diameter 14.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTFH “fiber count and type” – LSZH IEC60331-25 IEC60332-3-24 Cat.C – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2, EN 50268-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Colour code of fibers

  01.  02.  03.  04.  05.  06.  07.  08.  09.  10.  11.  12. 
Natural  Red  Green  Yellow  Brown  Blue  Violet  Orange  Grey  White  Black  Pink 

Other colour code available upon request.

 

Colour code of tubes

  Tube  4-12 fibers  24 fibers  36 fibers  48 fibers 
Red (4-12 fibers)  Red (12 fibers)  Red (12 fibers)  Red (12 fibers) 
Filler  Green (12 fibers)  Green (12 fibers)  Green (12 fibers) 
Filler  Filler  Natural (12 fibers)  Natural (12 fibers) 
Filler  Filler  Filler  Natural (12 fibers) 

Other colour code available upon request.

Ordering and delivery information

  Fiber count  P/N Packaging 
MTFH04xx  drum 2000m (+/-5%) 
MTFH08xx drum 2000m (+/-5%) 
12  MTFH12xx drum 2000m (+/-5%) 
24  MTFH24xx drum 2000m (+/-5%) 
36  MTFH36xx drum 2000m (+/-5%) 
48  MTFH48xx drum 2000m (+/-5%) 

xx = fiber type : OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 


MTB1 Fire Resistant Double Braided SHF1

   

 

 

 

Store at : -30 to +70 °C
Install at : – 5 to +50 °CBend minimum : 25 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 1500N/100mm
Impact maximum : 10J
Cable nominal weight : 350 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø1.9mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Thermoplastic resin coated single strand
Cable core : Loose tubes and fillers (when necessary) assembled around the central member. The core is wrapped by a synthetic tape.
Inner sheath : Black LSZH material 1.0mm thick. Nominal diameter 9.0mm.
Armour : Double layer of galvanized steel, tinned copper or bronze wires separated by a synthetic tape. Coverage ≥80%.
Outer jacket : Black LSZH SHF1 material 1.5mm thick. Nominal outer diameter 14.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable MTB1 “fiber count and type” – SHF1 IEC60331-25 IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Oil resistant : intermittent splash – permanent resistance available upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Colour code of fibers

  01.  02.  03.  04.  05.  06.  07.  08.  09.  10.  11.  12. 
Natural  Red  Green  Yellow  Brown  Blue  Violet  Orange  Grey  White  Black  Pink 

 

 

Colour code of tubes

  Tube  4-12 fibers  24 fibers  36 fibers  48 fibers  72 fibers 
Red (4-12 fibers)  Red (12 fibers)  Red (12 fibers)  Red (12 fibers)  Red (12 fibers) 
Filler  Green (12 fibers)  Green (12 fibers)  Green (12 fibers)  Green (12 fibers) 
Filler  Filler  Natural (12 fibers)  Natural (12 fibers)  Natural (12 fibers) 
Filler  Filler  Filler  Natural (12 fibers)  Natural (12 fibers) 
Filler  Filler  Filler  Filler  Natural (12 fibers) 
Filler  Filler  Filler  Filler  Natural (12 fibers) 

 

Ordering and delivery information

  Fiber count  SM  OM1  OM1+  OM2  OM3  OM4  Packaging 
MTB104S2  MTB104M1  MTB104ME  MTB104M2  MTB104M3  MTB104M4  drum 2000m (+/-5%) 
MTB108S2  MTB108M1  MTB108ME  MTB108M2  MTB108M3  MTB108M4  drum 2000m (+/-5%) 
12  MTB112S2  MTB112M1  MTB112ME  MTB112M2  MTB112M3  MTB112M4  drum 2000m (+/-5%) 
24  MTB124S2  MTB124M1  MTB124ME  MTB124M2  MTB124M3  MTB124M4  drum 2000m (+/-5%) 
36  MTB136S2  MTB136M1  MTB136ME  MTB136M2  MTB136M3  MTB136M4  drum 2000m (+/-5%) 
48  MTB148S2  MTB148M1  MTB148ME  MTB148M2  MTB148M3  MTB148M4  drum 2000m (+/-5%) 
72  MTB172S2  MTB172M1  MTB172ME  MTB172M2  MTB172M3  MTB172M4  drum 2000m (+/-5%) 

For an armour different than Galvanized Steel add “B” for bronze braid or “T” for tinned copper braid at the end of the P/N.

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


Multi Mode Optical Fiber Specification

  

 

Multi Mode Fibres OM1 MM62.5 OM1 + MM62,5 OM2 MM50 OM3 MM50 OM4 MM50 OM5 MM50
Applicable standards IEC60793-2-10 Type A1b IEC60793-2-10 Type A1b IEC60793-2-10 Type A1a.1 ISO/IEC 11801 ISO/IEC 11801 IEC60793-2-10 Type A1a.3 ISO/IEC 11801-OM5 IEC60793-2-10 Type A1a.4
Telcordia GR20-CORE Telcordia GR20-CORE Telcordia GR20-CORE IEC60793-2-10 Type A1a.2 Telcordia GR20-CORE Telcordia GR 20-CORE/409-CORE
ITU-T G651.1, Am.1 ITU-T G651.1, Am.1 ITU-T G651.1, Am.1 TIA/EIA-492AAAE
Core Diameter 62,5 ± 2 µm 62,5 ± 2.5 µm 50 ± 2 µm 50 ± 2 µm                          50 ± 2 µm 50 ± 2.5 µm
Core non-circularity ≤ 5 % ≤ 5 % ≤ 5 % ≤ 5 % ≤ 5 % ≤ 5 %
Cladding diameter 125 ± 1,0 µm 125  ± 1,0 µm 125  ± 1,0 µm 125  ± 1,0 µm 125  ± 1,0 µm 125  ± 1,0 µm
Coating diameter 242 ± 5 µm 242 ± 7 µm 242 ± 5 µm  242 ± 5 µm  242 ± 5 µm  242 ± 5 µm 
Cladding non-circularity ≤ 0,7 % ≤ 1,0 % ≤ 0,7 % ≤ 0,7 % ≤ 0,7 % ≤ 1,0 %
Core/Cladding concentricity error ≤ 1,0 µm ≤ 1,0 µm ≤ 1,0 µm    ≤ 1,0 µm    ≤ 1,0 µm    ≤ 1,5 µm   
Coating/Cladding concentricity error ≤ 10 µm ≤ 12 µm ≤ 6 µm ≤ 6 µm ≤ 6 µm ≤ 10 µm
Numerical aperture 0,275 ± 0,015 µm 0,275 ± 0,015 µm 0,200 ± 0,015 µm 0,200 ± 0,015 µm 0,200 ± 0,015 µm 0,200 ± 0,015 µm
Attenuation @ 850 nm ≤ 3,50 dB/km ≤ 2.80 dB/km ≤ 2,80 dB/km ≤ 2,80 dB/km ≤ 2,60 dB/km ≤ 2,40 dB/km
Attenuation @ 1300 nm ≤ 1,00 dB/km ≤ 0,70 dB/km ≤ 0,80 dB/km  ≤ 0,80 dB/km  ≤ 0,60 dB/km  ≤ 0,60 dB/km 
Bandwith @ 850 nm ≥ 200 MHz*km ≥ 250 MHz*km ≥ 500 MHz*km ≥ 1500 MHz*km ≥ 3500 MHz*km ≥ 3500 MHz*km
Bandwith @ 1300 nm ≥ 500 MHz*km ≥ 1000 MHz*km ≥ 500 MHz*km ≥ 500 MHz*km ≥ 500 MHz*km ≥ 500 MHz*km
Proof test ≥ 100 kpsi ≥ 100 kpsi ≥ 100 kpsi ≥ 100 kpsi ≥ 100 kpsi ≥ 100 kpsi
Link lenghts
100BASE FX 2000m 2000m 2000m 2000m 2000m 2000m
1000BASE SX 275m 500m 550m 1000m 1100m 1100m
1000BASE LX 550m 1000m 550m 550m 550m 550m
10GBASE SW/SR 565m 33m 82m 300m 550m 550m
10GBASE LX4 300m 300m 300m 300m
40GBASE SR4 100m 150m 150m
100GBASE SR10 100m 150m 100m

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 


QFCB / QFOB Armoured MUD NEK606 Fire Resistant IEC60331-25, Fire Retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 260 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket 1 : Black SHF1 material 1.2mm thick. Nominal outer diameter 13.5mm.
Outer jacket 2 : Black SHF2 thermoset material MUD Resistant 1.5mm thick. Nominal outer diameter 16.5mm.
Marking : APS Finland ww/yy – Fiber Optic Cable QF_B “fiber count and type” – SHF2 MUD RESISTANT NEK606 IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

 

 

Ordering and delivery information

Fiber count SM OM1 OM1+ OM2 OM3 OM4 Packaging
2 OQFCI02S2U OQFCI02M1U OQFCI02MEU OQFCI02M2U OQFCI02M3U OQFCI02M4U drum 2000m (+/-5%)
4 OQFCI04S2U OQFCI04M1U OQFCI04MEU OQFCI04M2U OQFCI04M3U OQFCI04M4U drum 2000m (+/-5%)
8 OQFCI08S2U OQFCI08M1U OQFCI08MEU OQFCI08M2U OQFCI08M3U OQFCI08M4U drum 2000m (+/-5%)
12 OQFCI12S2U OQFCI12M1U OQFCI12MEU OQFCI12M2U OQFCI12M3U OQFCI12M4U drum 2000m (+/-5%)
24 OQFCI24S2U OQFCI24M1U OQFCI24MEU OQFCI24M2U OQFCI24M3U OQFCI24M4U drum 2000m (+/-5%)
48 OQFCI48S2U OQFCI48M1U OQFCI48MEU OQFCI48M2U OQFCI48M3U OQFCI48M4U drum 2000m (+/-5%)

Note : for tinned copper braid add “T” at the end of the P/N, for bronze braid add “B” at the end of the P/N.

 

Colour code of fibers

01 02 03 04 05 06 07 08 09 10 11 12
White Red Yellow Green Blue Grey Brown Black Violet Turquoise Orange Pink

 

Colour code of tubes

Tube Type A   Type B          
2 fibers 4 fibers 8 fibers 12 fibers 24 fibers 48 fibers
1 Red (12 fibers) Red (2 fibers) Red (2 fibers) Red (4 fibers) Red (4 fibers) Red (6 fibers) Red (12 fibers)
2 Green (24 fibers) Filler Green (2 fibers) Green (4 fibers) Green (4 fibers) Green (6 fibers) Green (12 fibers)
3 Natural (36 fibers) Filler Filler Filler Natural (4 fibers) Natural (6 fibers) Natural (12 fibers)
4 Natural (48 fibers) Filler Filler Filler Filler Natural (6 fibers) Natural (12 fibers)
5 – (*) – (*) – (*) – (*) – (*) – (*) – (*)
6 – (*) – (*) – (*) – (*) – (*) – (*) – (*)
(*) filler only in case of 6 elements design

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


Fiber Optic cable FRSMTAHR , loose tube, armoured SWA, LSZH, fire resistant, fire retardant IEC60332-3-22 Cat.A

 

      

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 368 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.1mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : FRP
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. 
Inner sheath : Black LSZH material, fire retardant.
Armour : steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, oil resistant. Nominal outer diameter 15.2mm.
Marking : APS Finland ww/mm – Fiber Optic Cable FRSMTAHR “fiber count and type” – LSZH IEC60332-3-22 Cat.A  IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 
Oil resistant : intermittent splash
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber count P/N Packaging
2 FRSMTAHR02 ff drum 2000m (+/-5%)
4 FRSMTAHR04 ff drum 2000m (+/-5%)
8 FRSMTAHR08 ff drum 2000m (+/-5%)
12 FRSMTAHR12 ff drum 2000m (+/-5%)
24 FRSMTAHR24 ff drum 2000m (+/-5%)
48 FRSMTAHR48 ff drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, ME for OM1+, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Colour code of tubes

1 2 3 4 5 6 7 8 9 10 11 12 Fillers
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua Black

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


Fiber Optic cable FRSMTAU , loose tube, armoured SWA, MUD, fire resistant, fire retardant IEC60332-3-22 Cat.A

 

      

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 20 times O.D.
Pull maximum : 3000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 368 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.1mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : FRP
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. 
Inner sheath : Black LSZH material, fire retardant.
Armour : steel wire armour. Coverage ≥80%.
Outer jacket : Black LSZH material, fire retardant, MUD and oil resistant. Nominal outer diameter 16.0mm.
Marking : APS Finland ww/mm – Fiber Optic Cable FRSMTAU “fiber count and type” – LSZH MUD IEC60332-3-22 Cat.A  IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2 (-40°C)
Onshore : SEIC Cable Specification 1000-S-40-68-S-3014-00 Rev 06 sections 5.2.2.2 and 5.7

Ordering and delivery information

Fiber count P/N Packaging
2 FRSMTAU02 ff drum 2000m (+/-5%)
4 FRSMTAU04 ff drum 2000m (+/-5%)
8 FRSMTAU08 ff drum 2000m (+/-5%)
12 FRSMTAU12 ff drum 2000m (+/-5%)
24 FRSMTAU24 ff drum 2000m (+/-5%)
48 FRSMTAU48 ff drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, ME for OM1+, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

Colour code of fibers

1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Colour code of tubes

1 2 3 4 5 6 7 8 9 10 11 12 Fillers
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua Black

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


FRSCTAH type, loose tube, SWA armoured, LSZH, fire resistant, fire retardant

 

   

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 15 times O.D.
Pull maximum : 4000N
Crush maximum : 4000N/100mm
Impact maximum : 30J

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.8mm up to 12 fibers, Ø3.5mm 16-24) filled with jelly, housing up to 24 fibers
Colour code : See table
Fire protection :  mica tape wrapping.
Protection :  anti rodent glass yarns.
Inner sheath : red fire retardant LSZH material, typical thickness 1.0mm.
Armour : galvanised steel wires, helically applied. Min coverage 80%. 

Outer sheath : red fire retardant UVR LSZH material, typical thickness 1.0mm.
Marking :  APS Finland ww/mm – FRSCTAH UNI – FIBER OPTIC CABLE [Fibre type] – IEC 60331-25 – IEC 60332-3-24 – Lot no + meter 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-25 
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber count Outer diameter (mm) Weight (kg/km) Part Number Packaging
2 11.0 220 FRSCTAH 02 ff drum 2000m (+/-5%)
4 11.0 220 FRSCTAH 04 ff drum 2000m (+/-5%)
8 11.0 220 FRSCTAH 08 ff drum 2000m (+/-5%)
12 11.0 220 FRSCTAH 12 ff drum 2000m (+/-5%)
24 12.0 220 FRSCTAH 24 ff drum 2000m (+/-5%)

ff =  S2 for G652D, A1 for G657A1, M1 for OM1, ME for OM1+, M2 for OM2, M3 for OM3, M4 for OM4, M5 for OM5.

 

 

 

 

Colour code of fibers

01 02 03 04 05 06 07 08 09 10 11 12
White Red Yellow Green Blue Grey Brown Black Violet Turquoise Orange Pink

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


QFCI type, loose tube, armoured, SHF1, fire resistant IEC60331, fire retardant IEC60332-3-22 Cat.A

 

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +70 °CBend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 20J
Cable weight : 240 kg/km

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket : Black SHF1 material 1.2mm thick. Nominal outer diameter 13.5mm.
Marking : APS Finland ww/mm – Fiber Optic Cable QF_I “fiber count and type” – SHF1 IEC60332-3-22 Cat A IEC60331-25 – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25 (750°C, 3 hours – 1000°C, 3 hours)
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

Fiber count SM OM1 OM1+ OM2 OM3 OM4 Packaging
2 OQFCI02S21 OQFCI02M11 OQFCI02ME1 OQFCI02M21 OQFCI02M31 OQFCI02M41 drum 2000m (+/-5%)
4 OQFCI04S21 OQFCI04M11 OQFCI04ME1 OQFCI04M21 OQFCI04M31 OQFCI04M41 drum 2000m (+/-5%)
8 OQFCI08S21 OQFCI08M11 OQFCI08ME1 OQFCI08M21 OQFCI08M31 OQFCI08M41 drum 2000m (+/-5%)
12 OQFCI12S21 OQFCI12M11 OQFCI12ME1 OQFCI12M21 OQFCI12M31 OQFCI12M41 drum 2000m (+/-5%)
24 OQFCI24S21 OQFCI24M11 OQFCI24ME1 OQFCI24M21 OQFCI24M31 OQFCI24M41 drum 2000m (+/-5%)
48 OQFCI48S21 OQFCI48M11 OQFCI48ME1 OQFCI48M21 OQFCI48M31 OQFCI48M41 drum 2000m (+/-5%)

Note : for tinned copper braid add “T” at the end of the P/N, for bronze braid add “B” at the end of the P/N.

 

 

Colour code of fibers

01 02 03 04 05 06 07 08 09 10 11 12
White Red Yellow Green Blue Grey Brown Black Violet Turquoise Orange Pink

 

Colour code of tubes

Tube Type A   Type B          
2 fibers 4 fibers 8 fibers 12 fibers 24 fibers 48 fibers
1 Red (12 fibers) Red (2 fibers) Red (2 fibers) Red (4 fibers) Red (4 fibers) Red (6 fibers) Red (12 fibers)
2 Green (24 fibers) Filler Green (2 fibers) Green (4 fibers) Green (4 fibers) Green (6 fibers) Green (12 fibers)
3 Natural (36 fibers) Filler Filler Filler Natural (4 fibers) Natural (6 fibers) Natural (12 fibers)
4 Natural (48 fibers) Filler Filler Filler Filler Natural (6 fibers) Natural (12 fibers)
5 – (*) – (*) – (*) – (*) – (*) – (*) – (*)
6 – (*) – (*) – (*) – (*) – (*) – (*) – (*)
(*) filler only in case of 6 elements design

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


Single Mode Optical Fiber Specification

  

 

Single Mode Fibres OS2 OS2 OS2 OS2 NZD
Applicable standards ITU G652.D ITU G657.A IEC60793-2-50 Type B.1.3 / B.6.A ITU G657.B ITU G655.E / G656 IEC60793-2-50 Type B.4 / B5
IEC60793-2-50 Type B.1.3 Telcordia GR20-CORE IEC60793-2-50 Type B.1.3 / B.6.A&B
Telcordia GR20-CORE
Mode Field Diameter @ 1310nm 9,0 ± 0,4 µm 9,0 ± 0,4 µm 8,9 ± 0,4 µm
Mode Field Diameter @ 1550nm 10,1 ± 0,5 µm 10,1 ± 0,5 µm 9,9 ± 0,5 µm 9,2 ± 0,5 µm
Cladding diameter 125 ± 0,7 µm 125 ± 0,7 µm 125 ± 0,7 µm 125 ± 1,0 µm
Coating diameter 242 ± 7 µm 242 ± 7 µm 242 ± 7 µm 242 ± 7 µm
Cladding non-circularity ≤ 0,7 % ≤ 0,7 % ≤ 0,7 % ≤ 1,7 %
Core/Cladding concentricity error ≤ 0,5 µm ≤ 0,5 µm ≤ 0,5 µm ≤ 0,6 µm
Coating/Cladding concentricity error ≤ 12 µm ≤ 12 µm ≤ 12 µm ≤ 12 µm
Cable Cut off wavelength ≤ 1260 µm ≤ 1260 µm ≤ 1260 µm ≤ 1300 µm
Zero dispersion wavelength (λ0) 1300 ÷1322 µm 1300 ÷1322 µm 1300 ÷1324 µm ≤ 1440 µm
Dispersion slope (S0) @ (λ0) ≤ 0,090 ps/(nm2 * km) ≤ 0,090 ps/(nm2 * km) ≤ 0,092 ps/(nm2 * km)
Chromatic dispersion @ 1285—1330 nm ≤ 3,5 ps/(nm * km) ≤ 3,5 ps/(nm * km)
Chromatic dispersion @ 1550 ≤ 18 ps/(nm * km) ≤ 18 ps/(nm * km)
Chromatic dispersion @ 1625 ≤ 22 ps/(nm * km) ≤ 22 ps/(nm * km)
Chromatic dispersion @ 1530—1565 5,5 ÷ 10 ps/(nm * km)
Chromatic dispersion @ 1565—1625 7,5 ÷ 13,8 ps/(nm * km)
PMD @ 1550 nm ≤ 0,1 ps/√km ≤ 0,1 ps/√km ≤ 0,1 ps/√km ≤ 0,2 ps/√km
Attenuation @ 1310 nm ≤ 0,35 dB/km ≤ 0,35 dB/km ≤ 0,35 dB/km ≤ 0,40 dB/km
Attenuation @ 1383 nm ≤ 0,35 dB/km ≤ 0,35 dB/km ≤ 0,35 dB/km ≤ 1,00 dB/km
Attenuation @ 1550 nm ≤ 0,25 dB/km ≤ 0,25 dB/km ≤ 0,25 dB/km ≤ 0,25 dB/km
Attenuation @ 1625 nm ≤ 0,28 dB/km ≤ 0,28 dB/km ≤ 0,28 dB/km ≤ 0,28 dB/km
Attenuation with bending
Mandrel radius 15mmm @ 1550 10 turns ≤ 0,25 dB ≤ 0,03 dB
Mandrel radius 15mmm @ 1625 10 turns ≤ 1,0 dB ≤ 0,1 dB
Mandrel radius 10mmm @ 1550 1 turn ≤ 0,75 dB ≤ 0,1 dB
Mandrel radius 10mmm @ 1625 1 turn ≤ 1,50 dB ≤ 0,2 dB
Mandrel radius 7,5mmm @ 1550 1 turn ≤ 0,5 dB
Mandrel radius 7,5mmm @ 1625 1 turn ≤ 1,0 dB
Proof test ≥ 100 kpsi ≥ 100 kpsi ≥ 100 kpsi ≥ 100 kpsi
Link lenghts
1000BASE LX 5 000m 5 000m 5 000m 5 000m
10GBASE L 10 000m 10 000m 10 000m
10GBASE EW/ER 30 000m 40 000m 40 000m
40GBASE LR4 10 000m 10 000m 10 000m
100GBASE ER4 10 000m 10 000m 10 000m

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 
AP Solutions Oy – www.aps-finland.fi – info@apsolutions.fi