LIIN-25 FO Distribution cable TB FTMS 2-24 Universal

   

Features

Easy to Strip, Direct Termination
Non-Metallic Strength Members
Dry, All Dielectric Non-Metallic design
Halogen Free Fire Retardant / Low Smoke Zero Halogen
Flexible
Low Installation Cost

 

Standards of reference and applications

DIN VDE 0888 Part 6; IEC 61034; IEC 60332-1&2; IEC 60754-2; IEC 60794-1&2
Inter Building and Intrabuilding Voice and Data/LAN Communication Networks
Interconnection of Distribution Boxes, Distribution Frames and Customer Equipment and between the floors
Direct Connection to Terminal Equipments
Installation in Ducts & Conduits
Vertical Riser and General Horizontal Applications
FTTx Cabling

 

Installation Features

Store at  -5 to +50 °C
Install at  -0 to +50 °C
Operate at : -10 to +70 °C
Bend minimum : 10 times O.D.
Bend minimum : 10 times O.D.

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : 900μm tight, colour coded (see table 1)
Cable core : 2 to 24 optical fibers
Protection : glass or aramide yarns
Outer jacket : fire retardant LSZH material, UV resistant
Marking : APS Finland – ww/yy – Fiber Optic Cable TB FTMS fiber count x fiber type – LSZH-FR UVR IEC60332-3-24 – /lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH arvo ≥ 4,3 ja sähkönjohtavuus ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 ( ≤ 0.3%)
Smoke Emission : IEC 61034-2, EN 50268-2 (≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
UV resistant : UL1581, IEC11801

 

Fiber Optic characteristics

See detailed specification of optical fibers.

Colour code of fibers

                       
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/Black Orange/Black Green/Black Brown/Black Grey/Black White/Black Red/Black Natural Yellow/Black Violet/Black Pink/Black Aqua/Black

Ordering and delivery information

Fiber count P/N O.D [mm] Pulling tension (perm/inst) Crush (N) Impact Weight (kg/km) Packaging
2 FTMS02xxc 4.5 400/600 1000 3J 26 2000m / 6561ft
4 FTMS04xxc 5.5 400/600 1000 3J 31 2000m / 6561ft
6 FTMS06xxc 6.0 600/1000 1000 5J 42 2000m / 6561ft
8 FTMS08xxc 6.8 600/1000 1000 5J 48 2000m / 6561ft
12 FTMS12xxc 7.2 800/1200 1000 5J 54 2000m / 6561ft
16 FTMS16xxc 8.0 1000/1600 1000 5J 67 2000m / 6561ft
24 FTMS24xxc 8.6 1200/2000 1000 5J 85 2000m / 6561ft

xx = fiber type        ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
c = colour               ex. White=W, Yellow=Y, Orange=O, Grey=G,Turquoise=T, Purple=P

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 FO Distribution cable TB FTMS 48-96 cores Universal

   

Features

Easy to Strip, Direct Termination
Non-Metallic Strength Members
Dry, All Dielectric Non-Metallic design
Halogen Free Fire Retardant / Low Smoke Zero Halogen
Flexible
Low Installation Cost

 

Standards of reference and applications

DIN VDE 0888 Part 6; IEC 61034; IEC 60332-1&2; IEC 60754-2; IEC 60794-1&2, EN 187000
Inter Building and Intrabuilding Voice and Data/LAN Communication Networks
Interconnection of Distribution Boxes, Distribution Frames and Customer Equipment and between the floors
Direct Connection to Terminal Equipments
Installation in Ducts & Conduits
Vertical Riser and General Horizontal Applications
FTTx Cabling

 

Installation Features

Store at  -5 to +50 °C
Install at  -0 to +50 °C, Bend minimum : 15 times O.D.
Operate at : -10 to +70 °C, Bend minimum : 12 times O.D.

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : 900μm tight, colour coded (see table 1)
Cable core : 12 or 24 optical fibers
Protection : glass or aramide yarns
Sub-unit jacket : fire retardant LSZH material, UV resistant
Marking : numbering 1 to 8
Assembling: from 4 up to 8 sub-units assembled together into a compact core
Wrapping: polyester tape
Outer jacket : fire retardant LSZH material, UV resistant (nominal thickness 1.2mm)
Marking : APS Finland – ww/yy – Fiber Optic Cable TB FTMS “fiber count and type” – LSZH IEC60332-3-24 Cat.C – lot no – meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH arvo ≥ 4,3 ja sähkönjohtavuus ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 ( ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
UV resistant : UL1581, IEC11801

 

Fiber Optic characteristics

See detailed specification of optical fibers.

Colour code of fibers

                       
1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/Black Orange/Black Green/Black Brown/Black Grey/Black White/Black Red/Black Natural Yellow/Black Violet/Black Pink/Black Aqua/Black

Ordering and delivery information

Fiber count P/N O.D [mm]
Subcable
O.D [mm] Pulling tension (perm/inst) Crush (N) Impact Weight (kg/km) Packaging
48 FTMS48xxc 6.5 18.0 1500 1500 4J 350 500m / 1640ft
72 FTMS72xxc 6.5 22.0 1500 1500 4J 450 500m / 1640ft
96 (8×12) FTMS968xxc 6.5 22.0 1500 1500 4J 550 500m / 1640ft
96 (4×24) FTMS964xxc 8.6 21.0 1500 1500 4J 550 500m / 1640ft

xx = fiber type        ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
c = colour               ex. White=W, Yellow=Y, Orange=O, Grey=G,Turquoise=T, Purple=P

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIIN-25 FO Universal cable LTH Loose Tube 2-24 cores

   

Features

Compact, Light Weight and Small Size, Robust
Waterproof, UV- Resistant
All Dielectric, Non-Metallic Armored, Rodent Resistant
Halogen Free Fire Retardant / Low Smoke Zero Halogen
Enforcement with Non-Metallic Strenght Members

 

Applications

Inter Building and Intrabuilding Voice or Data Communication Networks General Purpose
Installed in Ducts & Conduits
Secondary Distribution
LAN
FTTB Cabling
Campus Cabling
Indoor and Outdoor (Universal Use)
Telecommunication Data Trunk Systems
Interconnection of Distribution Boxes, Distribution Frames and the Panels at Customer Side

Standards of reference

IEC 60754-1, IEC 61034-1&2, IEC 60332-1, IEC 60794-1&2

 

 

Installation Features

Store at  -5 to +50 °C
Install at  -0 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -30 to +70 °C, Bend minimum : 20 times O.D.

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube diam. 3.0mm, filled with jelly
Fiber count : 2 to 24
Protection : waterblocking glass yarns
Outer jacket : fire retardant LSZH material, UV resistant
Marking : APS Finland – ww/yy – Fiber Optic Cable CTH fiber count x fiber type – LSZH-FR UVR – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2, EN 50268-2
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : IEC 60332-1-2
UV resistant : UL1581, IEC11801

 

Fiber Optic characteristics

See detailed specification of optical fibers.

Colour code of fibers

                         
Bundle A 1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Bundle B 13 14 15 16 17 18 19 20 21 22 23 24
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

Ordering and delivery information

Fiber count P/N O.D [mm] Pulling tension (perm/inst) Crush (N) Impact Weight (kg/km) Packaging
2 CTH02xxc 7.5 1000/2500 1500 3J 62 2000m / 6561ft
4 CTH04xxc 7.5 1000/2500 1500 3J 62 2000m / 6561ft
6 CTH06xxc 7.5 1000/2500 1500 5J 62 2000m / 6561ft
8 CTH08xxc 7.5 1000/2500 1500 5J 62 2000m / 6561ft
12 CTH12xxc 7.5 1000/2500 1500 5J 62 2000m / 6561ft
16 CTH16xxc 8.5 1000/2500 1500 5J 90 2000m / 6561ft
24 CTH24xxc 8.5 1000/2500 1500 5J 90 2000m / 6561ft

xx = fiber type        ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
c = colour               ex. Yellow=Y, Orange=O, Grey=G, Turquoise=T, Purple=P, Black=B

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

Extended System Warranty

The APS System Warranty assures the compliance of the system performance to the applicable class of cabling for a period of 25 years. The warranty may be applied for by an accredited APS Partner who has designed and/or installed the entire system.

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.
AP Solutions Oy – www.aps-finland.fi – info@apsolutions.fi