LIACC FO Access cable ADSS 2-72 cores, Mid Span.

    
*All images are indicative

 

Features

Aerial installation on HT power lines
All Dielectric Non-Metallic design
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -40 to +70 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with jelly (nominal dial. 2.5 ± 0.1mm)
Central member :  FRP (nominal diameter 2.0mm).
Assembling :  tubes and fillers assembled together according to “Colour Code” table
Wrapping :  water blocking tape.
inner jacket :  Black MDPE material

Peripheral element :  aramide yarns with ripcord.
Outer jacket :  Black HDPE material, UV resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable ADSS MT80 fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  8000 N (Δα reversible, IEC 60794-1-2-E1)
Nominal span :  160m
Maximumspan :  280m
Crush :  3000N/100mm (Δα reversible, IEC 60794-1-2-E3)

Impact :  15J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

 

Colour code of tubes and fibers

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Blue Orange Green Brown Grey White (natural)
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Fillers Black

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Nominal O.D. (mm) Weight (kg/km) Packaging
2 MT8002xxMSPoo 1 2 5 14.0 145 Drum (2 or 4km)
4 MT8004xxMSPoo 1 4 5 14.0 145 Drum (2 or 4km)
8 MT8008xxMSPoo 1 8 5 14.0 145 Drum (2 or 4km)
12 MT80121xxMSPoo 1 12 5 14.0 145 Drum (2 or 4km)
12 MT80122xxMSPoo 2 6 4 14.0 145 Drum (2 or 4km)
24 MT8024xxMSPoo 2 12 4 14.0 145 Drum (2 or 4km)
48 MT8048xxMSPoo 4 12 2 14.0 145 Drum (2 or 4km)
72 MT8072xxMSPoo 6 12 0 14.0 145 Drum (2 or 4km)

xx = fiber type                  ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         ex. 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable ADSS 2-72 cores, Short Span

    
*All images are indicative

 

Features

Aerial installation on HT power lines
All Dielectric Non-Metallic design
Waterproof
HDPE and UV-Resistant outer jacket

 

Standards of reference and applications

IEC 60793, IEC 60794-1, IEC60794-3-20, ANSI/ICEA S-104-696, EN 187105, Telcordia GR-20 | Telcordia GR-409
Intrabuilding Voice and Data/LAN Communication Networks
Telecommunication
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +60 °C, Bend minimum  20 times O.D. 
Operate at  -40 to +70 °CBend minimum  15 times O.D. 

 

Design

Optical fiber :  125/250μm Single Mode or Multi Mode
Buffer :  PBTP loose tube filled with jelly (nominal dial. 2.5 ± 0.1mm)
Central member :  FRP (nominal diameter 2.0mm).
Assembling :  tubes and fillers assembled together according to “Colour Code” table
Wrapping :  water blocking tape.
Peripheral element :  aramide yarns with ripcord.
Outer jacket :  Black HDPE material, UV resistant
Marking :  APS Finland – ww/yy – Fiber Optic Cable ADSS MT30 fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  3000 N (Δα reversible, IEC 60794-1-2-E1)
Nominal span :  80m
Maximumspan :  120m
Crush :  2000N/100mm (Δα reversible, IEC 60794-1-2-E3)

Impact :  10J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

 

Colour code of tubes and fibers

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Blue Orange Green Brown Grey White (natural)
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Fillers Black

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers Nominal O.D. (mm) Weight (kg/km) Packaging
2 MT3002xxASPoo 1 2 5 11.0 110 Drum
4 MT3004xxASPoo 1 4 5 11.0 110 Drum
8 MT3008xxASPoo 1 8 5 11.0 110 Drum
12 MT30121xxASPoo 1 12 5 11.0 110 Drum
12 MT30122xxASPoo 2 6 4 11.0 110 Drum
24 MT3024xxASPoo 2 12 4 11.0 110 Drum
48 MT3048xxASPoo 4 12 2 11.0 110 Drum
72 MT3072xxASPoo 6 12 0 11.0 110 Drum

xx = fiber type                  ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         ex. 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable MTE 2-48 cores, Outdoor, 1500N

  
*All images are indicative

Features

Outdoor and duct installation
All Dielectric Non-Metallic design
Light weight

 

Standards of reference and applications

IEC 60793, IEC 60794
Intrabuilding Voice and Data/LAN Communication Networks
Installation in Ducts & Conduits
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at  -5 to +50 °C
Operate at  -40 to +60 °C
Bend minimum  20 times O.D. (installation)
Bend minimum  15 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly (nominal diameter 2.3mm).
Central member : FRP (nominal diameter 2.0mm).
Assembling : tubes and fillers assembled together according to “Colour Code” table
Wrapping :  water blocking tape.
Protection :  anti-rodent glass yarns.
Outer jacket : Black HDPE material, UV resistant (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – Fiber Optic Cable MTE fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  1500 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  2000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  10J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of tubes and fibers

  1 2 3 4 5 6 7 8 9 10 11 12
Tube Colours Blue Orange Green Brown Grey White (natural)
Fiber Colours Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
Fillers Black

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Fillers O.D. (mm) Weight (kg/km) Packaging          
2 MTE1502xxoo 1 2 5 11.5 60 Drum
4 MTE1504xxoo 1 4 5 11.5 60 Drum
8 MTE1508xxoo 1 8 5 11.5 60 Drum
12 MTE1512xxoo 1 12 5 11.5 60 Drum
24 MTE15243xxoo 3 8 3 11.5 60 Drum
24 MTE15242xxoo 2 12 4 11.5 60 Drum
48 MTE1548xxoo 4 12 2 11.5 60 Drum

xx = fiber type                  ex. OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         ex. 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable UT9H 2-24 cores, Outdoor, 1500N

  
*All images are indicative
Features

Outdoor and duct installation
Metallic armour and moisture barrier
Compact and light weight

 

Standards of reference and applications

IEC 60793, IEC 60794
Intrabuilding Voice and Data/LAN Communication Networks
Installation in Ducts & Conduits
Building access in FTTx networks

 

Installation Features

Store at  -30 to +70 °C
Install at  -5 to +50 °C, Bend minimum 20 times O.D. (installation)
Operate at  -45 to +60 °CBend minimum 15 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly (nominal diameter 2.3mm).
Protection :  anti-rodent glass yarns.
Armour:  corrugated steel tape.
Outer jacket : Black LSZH material, UV resistant 
Marking : APS Finland – ww/yy – Armoured Fiber Optic Cable UT9H fiber count x fiber type – P/N – lot + meter

 

Environmental properties

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas :
IEC 60754-1, IEC 60754-2
Smoke Emission :
IEC 61034-2, EN 50268-2
Toxicity of evolved gas :
EN 50305 9.2
Flame retardant : 
IEC 60332-1-2

Fire retardant : IEC 60332-3-24 Cat.C
UV resistant :
 UL1581, IEC11801

 

Mechanical properties

Pulling tension :  1500 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  1000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  10J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

1 2 3 4 5 6 7 8 9 10 11 12
Bundle A Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Bundle B Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Nominal O.D. (mm) Weight (kg/km) Packaging
2 UT9H02xxoo 1 2 8.5 85 Drum
4 UT9H04xxoo 1 4 8.5 85 Drum
8 UT9H08xxoo 1 8 8.5 85 Drum
12 UT9H12xxoo 1 12 8.5 85 Drum
24 UT9H24xxoo 1 24 8.5 85 Drum

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4
oo = delivery length         2000m=D2

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access cable UTAE 2-24 cores, Direct Burial, SWA Armoured

  
*All images are indicative
Features

Outdoor, duct and direct burial installation
Metallic armour and moisture barrier
Compact and light weight

 

Standards of reference and applications

IEC 60793, IEC 60794
Telecommunication backabones
Intrabuilding Voice and Data/LAN Communication Networks

Installation in Ducts & Conduits or Directly Buried
Building access in FTTx networks

 

Installation Features

Store at  -40 to +70 °C
Install at -10 to +60 °C, Bend minimum 20 times O.D. (installation)
Operate at  -40 to +70 °CBend minimum 10 times O.D. (static)

 

Design

Optical fiber : 125/250μm Single Mode or Multi Mode
Buffer : PBTP loose tube filled with jelly (nominal diameter 3.0mm).
Inner strength member :  aramide yarns.
Inner jacket :  PE black, nominal thickness 1.0mm.

Armour:  steel wire, one layer, coverage ≥80%.
Outer jacket : PE black, UV resistant, nominal thickness 1.5mm.
Marking : APS Finland – ww/yy – Armoured Fiber Optic Cable UTAE fiber count x fiber type – P/N – lot + meter

 

Environmental properties

UV resistant : UL1581, IEC11801

 

Mechanical properties

Pulling tension :  max 5000 N (Δα reversible, IEC 60794-1-2-E1)
Crush :  3000N/100mm (Δα reversible, IEC 60794-1-2-E3)
Impact :  15J (Δα reversible, IEC 60794-1-2-E4)
Water penetration :  3m cable, 1m water, 24 hours (IEC 60794-1-2-F5)

 

Colour code of fibers

1 2 3 4 5 6 7 8 9 10 11 12
Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua
13 14 15 16 17 18 19 20 21 22 23 24
Blue/black Orange/black Green/black Brown/black Grey/black White/black Red/black Natural Yellow/black Violet/black Pink/black Aqua/black

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number No. of tubes Fibers per tube Nominal O.D. (mm) Weight (kg/km) Packaging (*)
2 UTAE02xxoo 1 2 10.3 178 Drum
4 UTAE04xxoo 1 4 10.3 178 Drum
8 UTAE08xxoo 1 8 10.3 178 Drum
12 UTAE12xxoo 1 12 10.3 178 Drum
24 UTAE24xxoo 1 24 10.3 178 Drum

xx = fiber type                  OS2=S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=M5
oo = delivery length         2000m=D2
(*) a tolerance of ±5% applies to the delivery length.               

 

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


LIACC FO Access DROP cable BOWA 1-4 cores, self-supporting

    
*All images are indicative

 

Features

Aerial installation (F8 type)
All Dielectric Non-Metallic design
LSZH Fire Retardant
Suitable for both indoor and outdoor
UV-Resistant outer jacket
Small size
100% dry design
Low installation cost
Easy to strip
Direct Connection to Terminal Equıpments

 

Standards of reference and applications

EN 50173-1, IEC 60754-2, IEC 60794-1&2, IEC 60793-1&2, IEC 60332-1 & 2
FTTH Applications

Aerial (F8 Type with Steel Messenger Wire) 
Drop Cabling
Intrabuilding Voice or Data Communication Networks
Outdoor Interconnect and Patchcord Applications
Interconnection of Distribution Boxes, Distribution Frames and Customer Equipment and between the buildings
WAN
Aerial (Lashed)

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +60 °C
Operate at  -40 to +70 °C 

 

Design

Optical fiber :  1 to 4 cores 125/250μm, Single Mode or Multi Mode
Outer jacket :  Black LSZH-HFFR material

Self supporting element :  FRP rod 1.0mm
Peripheral pulling elements : 
FRP rod 0.5mm
Marking :  APS Finland – ww/yy – DROP Fiber Optic Cable BOWA fiber count x fiber type – P/N – lot + meter

 

Environmental properties

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness :
TS EN 50267-2-3
Smoke Emission :
IEC 61034-2
Flame retardant : 
IEC 60332-1-1, IEC60332-2-1
UV resistant :
 UL1581, IEC11801

 

Mechanical properties

Bending radius : 15 x O.D. (OS2 and MM), 10 x O.D. (G657A1/2)
Pulling tension, during installation :
  600 N
Pulling tension, permanent :  400 N
Crush :  600N/100mm (IEC 60794-1-2 E3)
Impact :  5J (Δα reversible, IEC 60794-1-2-E4)

 

 

Colour code of fibers

  1 2 3 4
Fiber Colours Blue Orange Green Brown

 

Fiber Optic characteristics

See detailed specification of optical fibers.

 

Ordering and delivery information

Fiber Count Part Number Nominal O.D. (mm) Weight (kg/km) Packaging
1 DRBA1xxxoo 5.2 x 2.0 21 Drum (1 or 2km)
2 DRBA2xxxoo 5.2 x 2.0 12 Drum (1 or 2km)
4 DRBA4xxxoo 5.2 x 2.0 12 Drum (1 or 2km)

xx = fiber type                  ex. OS2=S2, G657a1=7A1, G657a2=7A2, OM1=M1, OM2=M2, OM3=M3, OM4=M4, OM5=5
oo = delivery length         ex. 1000m=D1, 2000m=D2, 4000m=D4

Recommended connectivity

Pigtails : APS LIIN-25 series
Patch cords : APS LIIN-25 series
Adapters : APS LIIN-25 series
Patch Panels : APS LIIN-25 series

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.
AP Solutions Oy – www.aps-finland.fi – info@apsolutions.fi