75 Ohm coaxial cable RG11 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °CBend minimum: 15xO.D. (unarmored) or 20xO.D. (armored)

 

 

Design

Conductor : tinned copper Ø 1.63mm nominal
Dielectric : polyethylene nominal Ø 7.20mm
Screen 1 : aluminium tape
Screen 2 : copper wire braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 11 type MIL LSZH – 75 OHM – P/N – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 11 type MIL LSZH – 75 OHM – P/N – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

Electrical characteristics

Impedance : 75 ± 3 ᘯ 
Capacitance : 53pF/m nominal
Velocity ratio : 82%
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 100 200 400 600 800 1000
dB 4.7 6.5 9.5 12.3 14.0 16.2

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG11 Non-armoured RG11MT 10.0 145 500m or 1000m (+/-5%)
RG11 armoured GSWB RG11MTBH 14.2 232 500m (+/-5%)
RG11 armoured TCWB RG11MTTH 14.2 218 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


75 Ohm coaxial cable RG59 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -10 to +70 °CBend minimum: 5xO.D. (unarmored) or 15xO.D. (armored)

 

 

Design

Conductor : copperweld Ø 0.58 ± 0.025 mm
Dielectric : low density polyethylene nominal Ø 3.70mm
Screen 1 : aluminium/poleysther/aluminium tape
Screen 2 : bare copper braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 59 type MIL LSZH – 75 OHM – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 59 type MIL LSZH – 75 OHM – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

 

Electrical characteristics

Impedance : 75ᘯ nominal 
Capacitance : 67pF/m nominal
Inner conductor resistance @ 500V : 154Ω/km nominal
Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 4.0 5.4 9.3 14.7 19.0 23.6 29.8 32.0 37.5 42.6 51.7 54.8 59.2 65.6 69.7 73.0 77.7 61.1

 

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG59 Non-armoured RG59MT 6.2 57.2 500m or 1000m (+/-5%)
RG59 armoured GSWB RG59MTBH 9.4 144.2 500m (+/-5%)
RG59 armoured TCWB RG59MTTH 9.4 130.0 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


75 Ohm Coaxial cable RG6 CCS double screen PVC

 

Installation Features

Store at  -10 to +50 °C
Install at  -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -0 to +60 °CBend minimum : 20 times O.D.
Pull maximum : 100N

 

Design

Conductor :  solid CCS 1.02mm
Dielectric :  foam PE nominal Ø 4.60mm
Screen 1 :  bonded AL/P nominal Ø 4.75mm
Screen 2 :  Aluminium wire braid nominal coverage 60%

Jacket : black PVC material nominal Ø 6.86mm
Marking :  APS Finland – ww/yy – 75 Ohm CATV RG6 CCS – P/N CCS6AB6VKB3 – lot – meter

 

Environmental properties and Fire Performances

Flame retardant : IEC60332-1-2

 

Electrical Characteristics

Characteristic impedance (Ohm) 75+/-3
Capacitance (pF/m) 52+/-2
Velocity of Propagation (%) 85.0
Return Loss (dB) 5-1000MHz ≥22

Frequency Attenuation
db/100ft
Attenuation
dB/100 meter
55 1.6 5.2
187 2.8 9.3
211 3.1 10
400 4.1 13.5
500 4.6 15.0
750 5.6 18.5
860 6.1 20.0
1000 6.6 21.5

 

Recommended connectivity

BNC connectors : APS BNC75

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


75 Ohm coaxial cable RG6 LSZH MIL Type

  

 

 

Store at: -0 to +60 °C
Install at: 0 to +50 °CBend minimum: 10xO.D. (unarmored) or 20xO.D. (armored)
Operate at: -20 to +70 °CBend minimum: 5xO.D. (unarmored) or 15xO.D. (armored)

 

 

Design

Conductor : bare copper Ø 1.02mm nominal
Dielectric : low density polyethylene nominal Ø 4.60mm
Screen 1 : aluminium tape
Screen 2 : aluminium wire braid 
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – RG 6 type MIL LSZH – 75 OHM – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel or tinned copper wire braid
Outer jacket : black LSZH material
Marking : APS Finland – ww/yy – ARMOURED RG 6 type MIL LSZH – 75 OHM – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas corrosiveness : TS EN 50267-2-3
Smoke Emission : IEC 61034-2
Flame retardant : IEC 60332-1-1, IEC60332-2-1

Electrical characteristics

Impedance : 75 ± 3 ᘯ 
Capacitance : 53pF/m nominal
Insulation resistance :  10000 MΩ x Km

Spark tension of the sheath : 2.0 kV

 

Attenuation (typical)

MHz 100 200 300 400 600 800 1000
dB 7.0 10.2 12.0 14.8 18.5 20.8 24.8

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG6 Non-armoured RG6MT 7.0 110 500m or 1000m (+/-5%)
RG6 armoured GSWB RG6MTBH 11.2 197 500m (+/-5%)
RG6 armoured TCWB RG6MTTH 11.2 183 500m (+/-5%)

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

AP Solutions Oy – www.aps-finland.fi – info@apsolutions.fi