MOG 50 Ohm coaxial cable RG213U SHF1 unarmoured and armoured

 

    

 

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 10 times O.D.
Operate at: -30 to +70 °CBend minimum: 5 times O.D

 

 

Design

Conductor : stranded bare copper 7×0.75mm
Dielectric : low density polyethylene Ø 7.25 ± 0.18 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 29mm)
Screen 2 : bare copper braid (coverage 96%)
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG213 MARINE SHF1 – 50 OHM – IEC60332-3-24 Cat C – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG213 MARINE SHF1 ARMOURED – 50 OHM – IEC60332-3-24 Cat C – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : available upon request
Weather resistant : available upon request
LSZH SHF2 : available upon request
Oil resistant : available upon request
MUD resistant : available upon request
Water resistant : available upon request
Water penetration : available upon request
UV resistant : YES – ASTM-D-2565-92A

 

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 50 ± 5 ᘯ
Capacitance : 100 ± 3 pF/m
Velocity ratio :  66%
Inner conductor resistance @ 500V : 36.5 ± 1.5 Ω/km
Braid resistance @ 500V : 14 ± 4 Ω/km
Spark tension of the sheath : 4.0kV

Attenuation

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 1.4 1.9 3.9 5.6 8.3 10.3 13.7 15.3 17.9 20.3 24.7 26.1 29.8 33.6 34.7 37.1 39.5 41.7

Return Loss (IEC61196-1-113)

MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >22 >22 >22 >19 >18

 

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging
RG213U Non-armoured OC50R213U1 10.3 167.5 500m or 1000m (+/-5%)
RG213U GSWB armoured OC50R213A1 13.7 303.6 500m (+/-5%)
RG213U TCWB-armoured OC50R213T1 13.7 290.5 500m (+/-5%)
RG213U BWB armoured OC50R213B1 13.7 300.6 500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20 Type Approval Program – coaxial cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 

 


MOG 50Ohm coaxial cable RG214U SHF1 unarmoured and armoured

    

 

 

Store at: -20 to +60 °C
Install at: 0 to +50 °C
Bend minimum: 10 times O.D.
Operate at: -30 to +70 °C
Bend minimum: 5 times O.D

 

 

Design

Conductor : stranded silvered copper 7×0.75mm
Dielectric : low density polyethylene Ø 7.25 ± 0.18 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 29mm)
Screen 2 : silvered copper braid (coverage 94%)
Screen 3 : silvered copper braid (coverage 98%)
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG214 MARINE SHF1 – 50 OHM – IEC60332-3-24 Cat.C – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG214 MARINE SHF1 ARMOURED – 50 OHM – IEC60332-3-24 Cat.C – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO
Weather resistant : NO
LSZH SHF2 : NO
Oil resistant : NO
MUD resistant : NO
Water resistant : NO
Water penetration : NO
UV resistant : YES – ASTM-D-2565-92A

 

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 50 ± 3 ᘯ
Capacitance : 100 ± 9 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 6 ±1.5 Ω/km
Braid resistance @ 500V : 4.4 ± 4 Ω/km
Spark tension of the sheath : 5.5 kV

Attenuation

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 1.4 1.9 3.9 5.6 8.3 10.3 13.7 15.3 17.9 20.3 24.7 26.1 29.8 33.6 34.7 37.1 39.5 41.7


Return Loss (IEC61196-1-113)

MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >22 >22 >22 >19 >18

 

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging
RG213U Non-armoured OC50R213U1 10.8 2102.2 500m or 1000m (+/-5%)
RG213U GSWB armoured OC50R213A1 14.8 370.3 500m (+/-5%)
RG213U TCWB-armoured OC50R213T1 14.8 350.3 500m (+/-5%)
RG213U BWB armoured OC50R213B1 14.8 365.0 500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20 Type Approval Program – coaxial cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


MOG 50Ohm coaxial cable RG58CU SHF1 unarmoured and armoured

 

    

 

Store at: -40 to +70 °C
Install at -10 to +50 °C Bend minimum:  15 times O.D.
Operate at -30 to +70 °C, Bend minimum 10 times O.D.
Crush maximum :  2000N/100mm
Impact maximum:
 25J

 

 

Design

Conductor : stranded tinned copper 19×0.18mm
Dielectric : low density polyethylene Ø2.95 ± 0.10 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 15mm)
Screen 2 : tinned copper braid (coverage 93%) 
Outer jacket (inner jacket for armoured version):  black Fire Retardant and UV Resistant SHF1 material, LSZH 

Marking : APS Finland – ww/yy – RG58 MARINE SHF1 – 50 OHM – IEC60332-3-24 Cat C – lot + meter 

Armoured version is supplied with additional: 
Armour : galvanized steel wire braid (tinned copper wire and bronze wire braid available upon request) 
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH 
Marking : APS Finland – ww/yy – RG58 MARINE SHF1 “ARMOUR TYPE” – 50 OHM – IEC60332-3-24 Cat C – lot + meter 

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : NO – IEC 60092-359:1987-03
Oil resistant : NO (oil, fuels and hydrocarbons) – IEC60811
MUD resistant : NO – NEK 606:2009
Water resistant : YES – IEC60502
Water penetration : YES – IEC 60794-1-2-F5-B (inner core only)
UV resistant : YES – ASTM-D-2565-92A

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 50 ± 3 Ω
Capacitance : 100 ± 9 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 6 ± 1.5 Ω/km Braid resistance @ 500V : 4.4 ± 1.5 Ω/km
Spark tension of the sheath : 5.5 kV
Attenuation

  MHz  10  50  100  200  300  500  600  800  1000  1350  1500  1750  2150  2250  2500  2750  3000 
dB 3.3 4.3 9.9 13.5 19.2 24.0 31.9 35.5 41.6 47.5 57.1 60.8 67.1 77.0 78.8 85.7 88.9 90.7

Return Loss (IEC61196-1-113)

MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >28 >23 >20 >15 >15

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging
RG58 Non-armoured OC50R58U1 5.0 41.0 500m or 1000m (+/-5%)
RG58 GSWB armoured OC50R58A1 10.0 11.5 500m (+/-5%)
RG58 TCWB armoured OC50R58T1 10.0 110.0 500m (+/-5%)
RG58 BWB armoured OC50R58B1 10.0 120.5 500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20 Type Approval Program – coaxial cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 


MOG 75Ohm coaxial cable RG11AU SHF1 unarmoured and armoured

 

    

 

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 10/20 times O.D.
Operate at: -30 to +70 °CBend minimum: 5/15 times O.D

Design

Conductor : tinned copper 7×0,40mm
Dielectric : low density polyethylene Ø 7.25 ± 0.18 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 29mm)
Screen 2 : bare copper braid (coverage 96%)
Screen 3 : N/A
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG11 MARINE SHF1 – 75 OHM – IEC60332-3-24 Cat.C – DNV – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG11 MARINE SHF1 ARMOURED – 75 OHM – IEC60332-3-24 Cat.C – DNV – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO
Weather resistant : NO
LSZH SHF2 : NO
Oil resistant : NO
MUD resistant : NO
Water resistant : NO
Water penetration : NO
UV resistant : YES – ASTM-D-2565-92A

 

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 75 ± 3 ᘯ
Capacitance : 67 ± 3 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 20.5  ± 1.5 Ω/km
Braid resistance @ 500V : 4.4 ± 1.5 Ω/km Spark tension of the sheath : 5.5 kV


Attenuation

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 1.4 2.0 5.0 7.2 10.5 13.0 17.1 19.0 22.4 25.5 30.4 32.5 35.6 40.9 41.6 44.1 46.5 50.1

Return Loss (IEC61196-1-113)

MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >27 >27 >23 >18 >16

 

 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging    
RG11U Non-armoured OC75R11U1 10.3 149.6 500m or 1000m (+/-5%)
RG11U GSWB armoured OC75R11A1 13.7 285.7 500m (+/-5%)
RG11U TCWB armoured OC75R11T1 13.7 265.0 500m (+/-5%)
RG11U BWB armoured OC75R11B1 13.7 270.0 500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20 Type Approval Program – coaxial cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 


Coaxial cable 50 Ohm PLENUM RG58/U

  

 

Store at: -40 to +70 °C
Install at -10 to +50 °C, Bend minimum 15 times O.D.
Operate at -40 to +200°C, Bend minimum 10 times O.D.
Max recommended pulling tension 40 lbs

 

Design

Conductor : stranded barecopper AWG20 19×32
Dielectric : foam FEP 0.102″
Screen 1 : tinned copper braid coverage 95%
Outer jacket :  Ivory FEP 0.158″ nom.
Marking : APS Finland – ww/yy – RG58 PLENUM – 50 OHM – 200ºC FT6 – lot + ft

Note :  the Jacket is sequentially footmarked.

 

Environmental properties and Fire Performances

Flame retardant : NFPA 262 PLENUM, FT6

 

Electrical characteristics 

Impedance : 52 Ω nominal
Capacitance : 25 pF/ft nominal (@ 1KHz)
Velocity ratio : 82%
DC resistance @ 20ºC : 8.8 Ω/1m nominal

Attenuation

  MHz  1 10  50  100  400 700  900  1000 
dB/100FT 0.5 1.3 3.2 4.9 11.1 15.3 18.4 19.6

 

 

Ordering and delivery information

Type P/N O.D [in / mm] Weight [lbs/m / kg/m] Packaging (standard)
RG58/U PLENUM C50R58P 0.158 / 4.0 0.17 / 7.72 1000ft or 305m (+/-5%)

 

 

Other standards of reference

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 


MOG 75Ohm coaxial cable RG59BU SHF1 unarmoured and armoured

 

    

 

 

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 10/20 times O.D.
Operate at: -30 to +70 °CBend minimum: 5/15 times O.D.

 

 

Design

Conductor : copperweld Ø 0.58 ± 0.025 mm
Dielectric : low density polyethylene Ø 3.70 ± 0.15 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 18mm)
Screen 2 : bare copper braid (coverage 93%)
Screen 3 : N/A
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG59 MARINE SHF1 – 75 OHM – IEC60332-3-24 Cat.C – DNV – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG59 MARINE SHF1 ARMOURED – 75 OHM – IEC60332-3-24 Cat.C – DNV – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO
Weather resistant : NO
LSZH SHF2 : NO
Oil resistant : NO
MUD resistant : NO
Water resistant : NO
Water penetration : NO
UV resistant : YES – ASTM-D-2565-92A

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 75 ± 3 ᘯ
Capacitance : 67 ± 3 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 154 ± 5 Ω/km
Braid resistance @ 500V : 9 ± 3 Ω/km
Spark tension of the sheath : 4.5 kV

 

Attenuation

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 2.7 3.4 7.3 10.7 15.0 18.6 24.8 27.0 31.5 35.6 41.7 44.8 49.2 55.6 59.7 63.0 67.7 50.1


Return Loss (IEC61196-1-113)

MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >28 >23 >18 >14 >14


 

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging  
RG59BU Non-armoured OC75R59U1 6.2 57.2 500m or 1000m (+/-5%)
RG59BU GSWB armoured OC75R59A1 9.4 144.2 500m (+/-5%)
RG59BU TCWB armoured OC75R59T1 9.4 130.0 500m (+/-5%)
RG59BU BWB armoured OC75R59B1 9.4 140.5 500m (+/-5%)

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20 Type Approval Program – coaxial cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


MOG 75Ohm multi-coaxial cable 3 x RG59BU LSZH

   

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 10/20 times O.D.
Operate at: -30 to +70 °CBend minimum: 5/15 times O.D.

Design

Conductor : copperweld Ø 0.58 ± 0.025 mm
Dielectric : low density polyethylene Ø 3.70 ± 0.15 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 18mm)
Screen 2 : bare copper braid (coverage 93%)
Jacket 1 : black Fire Retardant LSZH material, white numbered 1 to 3
Assembling : 3 numbered coaxial cables stranded together into a compact core, with fillers if needed (fillers are always used for the armoured version).

Jacket 2 : black Fire Retardant LSZH material
Marking : APS Finland – ww/yy – 3 x RG59 BU – 75 OHM – LSZH – lot + meter

Armoured version is supplied with additional:
   Armour : galvanized steel, copper or bronze wire braid
   Outer jacket : black LSZH Fire Retardant and UV Resistant thermoplastic material
   Marking : APS Finland – ww/yy – ARMOURED 3 x RG59 BU – 75 OHM – LSZH UVR – lot + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 
Halogen acid gas : IEC 60754-1, IEC 60754-2
Smoke Emission : IEC 61034-2, EN 50268-2 
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 75 ± 3 ᘯ
Capacitance : 67 ± 3 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 154 ± 5 Ω/km
Braid resistance @ 500V : 9 ± 3 Ω/km
Spark tension of the sheath : 4.5 kV

 

Attenuation

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 2.7 3.4 7.3 10.7 15.0 18.6 24.8 27.0 31.5 35.6 41.7 44.8 49.2 55.6 59.7 63.0 67.7 50.1

Return Loss (IEC61196-1-113)

MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >28 >23 >18 >14 >14

 

Ordering and delivery information

Type P/N Nom. diam. [mm]
Single cable
Nom. O.D [mm] Weight [kg/km] Packaging
RG59BU Non-arm. C75R59UZ 6.2 14.0 186.6 500m (+/-5%)
RG59BU GSWB C75R59AZ 6.2 18.0 447.6 500m (+/-5%)
RG59BU TCWB C75R59TZ 6.2 18.0 405.0 500m (+/-5%)
RG59BU BWB C75R59BZ 6.2 18.0 436.5 500m (+/-5%)

 

 

Other standards of reference

MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


MOG 75Ohm coaxial cable RG6AU SHF1 unarmoured and armoured

    

 

 

 

Store at: -20 to +60 °C
Install at: 0 to +50 °CBend minimum: 10/20 times O.D.
Operate at: -30 to +70 °CBend minimum: 5/15 times O.D.

Design

Conductor : copperweld Ø 0,72 ± 0.025 mm
Dielectric : low density polyethylene Ø 4.70 ± 0.20 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 20mm)
Screen 2 : silvered copper braid (coverage 96%)
Screen 3 : plain copper braid (coverage 96%)
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG6 MARINE SHF1 – 75 OHM – IEC60332-3-24 Cat.C – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG6 MARINE SHF1 ARMOURED – 75 OHM – IEC60332-3-24 Cat.C – DNV – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO
Weather resistant : NO
LSZH SHF2 : NO
Oil resistant : NO
MUD resistant : NO
Water resistant : NO
Water penetration : NO
UV resistant : YES – ASTM-D-2565-92A

 

 

Electrical characteristics (IEC60092-350, EN 50290-2-23, IEC61196-1-108)

Impedance : 75 ± 3 ᘯ Capacitance : 67 ± 3 pF/m
Velocity ratio : 66%
Inner conductor resistance @ 500V : 97 ± 3 Ω/km
Braid resistance @ 500V : 5 ± 3 Ω/km
Spark tension of the sheath : 6 kV


Attenuation

MHz 5 10 50 100 200 300 500 600 800 1000 1350 1500 1750 2150 2250 2500 2750 3000
dB 2.0 2.8 6.0 8.5 12.0 15.0 19.8 21.9 25.5 29.1 34.2 36.6 39.9 45.6 46.5 49.4 52.0 55.8
4

Return Loss (IEC61196-1-113)

MHz 30 ÷ 300 300 ÷ 600 600 ÷ 1000 1000 ÷ 2000 2000 ÷ 3000
dB >28 >20 >19 >16 >15

Ordering and delivery information

Type P/N O.D [mm] Weight [kg/km] Packaging    
RG6AU Non-armoured OC75R6U1 8.5 125.5 500m or 1000m (+/-5%)
RG6AU GSWB armoured OC75R6A1 11.5 229.4 500m (+/-5%)
RG6AU TCWB armoured OC75R6T1 11.5 208.5 500m (+/-5%)
RG6AU BWB armoured OC75R6B1 11.5 219.5 500m (+/-5%)

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.10/20 Type Approval Program – coaxial cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

AP Solutions Oy – www.aps-finland.fi – info@apsolutions.fi