CCTV cable 2 optical fibers, 3 Power cores, SHF1

   

Store at : -40 to +80 °C
Install at : -10 to +50 °C, Bend minimum : 25 (arm.) or 12 (non-arms.) times O.D.
Operate at : -40 to +80 °C, Bend minimum : 20 (arm.) or 15 (non-arms.) times O.D.
Pull maximum : 1000N
Crush maximum : 200N/100mm

Design

 

Fiber optic 2 Cores

Fiber : Fiber: 125/250µm SM or MM (see Fiber Characteristics datasheets)
Buffer : PBTP tube nominal diam 1.8mm filled with jelly (alternatively tight buffer design)
Colour code : 1.Natural 2.Red 
Protection : Glass yarns (alternatively aramide yarns)
Jacket : LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 3.5mm

Power, 3 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2 (According to Class 5 IEC 60228, Ø of strands 0.25mm)
Insulation : cross linked polyethylene (XLPE) nominal Ø 3.5mm, colour coded (1.Brown, 2.Blue, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 8.21 Ω/km
Insulation resistance @ 20°C : ≥ ≥ 1GΩ x km
Operating Voltage : 600/1000V
Test Voltage : 3500 V AC x 1 minute

Assembling

Cable core : power and fiber elements stranded together around a central filler and wrapped by synthetic tape
Inner jacket (outer for non-armoured version) : non-corrosive thermoplastic compound, LSZH SHF1, nom. Ø 11.0mm, black colour
Marking (non-armoured version) : APS Finland – ww/yy – COMPOSITE CABLE 2xFO 3×2.5mm² – P/N – LSZH SHF1 IEC60332-3-22 Cat.A – lot + meter mark

Armour : galvanized steel wire armour, coverage ≥85%
Outer jacket : non-corrosive thermoplastic compound LSZH, nom. Ø 15.0mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE 2xFO 3×2.5mm² – P/N – LSZH SHF1 IEC60332-3-22 Cat.A – lot + meter mark

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : IEC 60794-1-2-F5-B (fiber unit), upon request for the whole inner core.
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

  P/N  O.D [mm]  Weight [kg/km]  Packaging 
OC3252xx1 non-armoured  11.0  370  drum 500m (+/-5%) 
OC3252xxHF1 armoured  15.0  480  drum 500m (+/-5%) 

xx = Fiber type : OS2=S2 – OM1=M1 – OM2=M2 – OM3=M3 – OM4=M4

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.
 

 

 

 

 


CCTV cable 4 optical fibers, 3 Power cores, SHF1

   

 

 

Store at : -40 to +80 °C
Install at : -10 to +50 °C, Bend minimum : 15 times O.D.
Operate at : -40 to +80 °C, Bend minimum : 12 times O.D.
Pull maximum : 1000N
Crush maximum : 200N/100mm

Design

 

Fiber optic 4 Cores

Fiber : Fiber: 125/250µm SM or MM (see Fiber Characteristics datasheets)
Buffer : PBTP tube nominal diam 1.8mm filled with jelly (alternatively tight buffer design)
Colour code : 1.Natural 2.Red 3.Green 4.Yellow
Protection : Glass yarns (alternatively aramide yarns)
Jacket : LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 3.5mm

Power, 3 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2 (According to Class 5 IEC 60228, Ø of strands 0.25mm)
Insulation : cross linked polyethylene (XLPE) nominal Ø 3.5mm, colour coded (1.Brown, 2.Blue, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 8.21 Ω/km
Insulation resistance @ 20°C : ≥ ≥ 1GΩ x km
Operating Voltage : 600/1000V
Test Voltage : 3500 V AC x 1 minute

Assembling

Cable core : power and fiber elements stranded together around a central filler and wrapped by synthetic tape
Inner jacket (outer for non-armoured version) : non-corrosive thermoplastic compound, LSZH, nom. Ø 11.0mm, black colour
Marking (non-armoured version) : APS Finland – ww/yy – COMPOSITE CABLE OC3254_H – LSZH IEC60332-3-22 Cat.A
Armour : galvanized steel wire armour, coverage ≥85%
Outer jacket : non-corrosive thermoplastic compound LSZH, nom. Ø 15.0mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC3254__HFH – LSZH IEC60332-3-22 Cat.A – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : IEC 60794-1-2-F5-B (fiber unit), upon request for the whole inner core.
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

  P/N  O.D [mm]  Weight [kg/km]  Packaging 
OC3254xx1 non-armoured  11.0  370  drum 500m (+/-5%) 
OC3254xxHF1 armoured  15.0  480  drum 500m (+/-5%) 

xx = Fiber type : OS2=S2 – OM1=M1 – OM2=M2 – OM3=M3 – OM4=M4

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.
 

 

 

 

 


CCTV cable 75 Ohm coax RG59, Signal 2 pairs, Power 3×1.5, SHF1

   

 

 

Store at : -10 to +70 °C
Install at : -10 to +50 °C, Bend minimum : 20 x O.D.
Operate at : -34 to 80 °C, Bend minimum : 25 x O.D.

 

 

Design

Coaxial, 75Ohm RG59

Inner conductor : solid bare copper wire Class 1 0.58mm
Dielectric : polyethylene nominal Ø 3.70
Braid : bare copper, coverage ≥95%
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 6.15 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 154 ± 5 Ω/km
Resistance braid : 9 ± 3 Ω/km
Attenuation : @ 500MHz 24.8 dB/100m
Attenuation : @ 1000MHz 35.6 dB/100m
Attenuation : @ 3000MHz 67.7 dB/100m
Return Loss : @ 3000MHz > 14.0 dB
 

Signal, 2 pairs AWG24

Conductor : stranded tinned copper AWG24/7 strands
Insulation : polyethylene nominal thickness 0.40mm
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.8mm, colour coded (1.Black 2.Grey)
Resistance of conductor @ 20°C : 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute

Power, 3 cores 1.5mm2

Conductor : stranded tinned copper 1.5mm2
Insulation : cross linked polyethylene nominal Ø 3.0mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : 12.1 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core :  coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version) :  SHF1 thermoplastic compound, nom. thickness 0.80mm, black colour
Marking :  APS Finland – ww/yy – COMPOSITE CABLE OC75592P24315H – SHF1 IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire braid, coverage ≥85% (Alternatives : Bronze braid, Stainless steel braid)
Outer jacket : non-corrosive thermoplastic compound, SHF1, nom. thickness 1.50mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC75592P24315HF2H – SHF1 IEC60332-3-24 – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OC75592P243151  17.0  380  drum 500m (+/-5%) 
Armoured GSWB  OC75592P24315HF21  22.0  480  drum 500m (+/-5%) 
Armoured GSWA  OC75592P24315HFA1  24.0  500  drum 500m (+/-5%) 
Armoured Bronze braid  OC75592P24315HFB1  22.0  480  drum 500m (+/-5%) 
Armoured St. Steel braid  OC75592P24315HSA1  24.0  540  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


CCTV cable 75Ohm coax 1xRG11 2P 3C SHF1 Fire Resistant

   

 

 

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +80 °CBend minimum : 20 times O.D

Design

Coaxial 75Ohm RG11

Inner conductor : stranded tinned copper 7×0.40mm
Dielectric : PE + Silicone Ø 7.25 ± 0.18 mm
Braid : bare copper, coverage 97%
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen Ø 10.3 ± 0.20 mm
Velocity : 67%
Capacitance : 67 pF/m
Resistance conductor : 20.5 Ω/km R
Resistance braid : 4.4 Ω/km
Attenuation @ 1000MHz : 23.4 dB/100m
Attenuation @ 3000MHz : 50.1 dB/100m
Return Loss @ 900MHz : > 20.0 dB
Screening effectiveness : > 20.0 dB

Signal, 2 pairs AWG22

Conductor : stranded tinned copper AWG22/7 (0.88mm2)
Insulation :fire resistant tape + XLPE nominal Ø 2.75
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.3mm, colour coded (1.Black 2.Blue)
Resistance of conductor @ 20°C :≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage :  1000 V DC x 1 minute

Power, 3 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : fire resistant tape + cross linked polyethylene nominal Ø 3.3mm, colour coded (1.Black, 2.Red, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 7.98 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version) :
SHF1 thermoplastic compound, black colour (other colours upon request)
Marking :
APS Finland – ww/yy – COMPOSITE CABLE OCX75112P223251 – SHF1 IEC60331-23 IEC60332-3-24 – lot + m

Armoured version
Armour : galvanized steel wire braid, coverage ≥80% (alternatives : Bronze braid, Stainless steel braid)
Outer jacket : SHF1 thermoplastic compound, black colour (other colours upon request)
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE “PN” – SHF1 IEC60331-23 IEC60332-3-24 – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331-23
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OCX75112P223251  18.0  480  drum 500m (+/-5%) 
Armoured GSWB  OCX75112P223251F21  26.0  580  drum 500m (+/-5%) 
Armoured GSWA  OCX75112P223251 FA1  27.0  620  drum 500m (+/-5%) 
Armoured Bronze braid  OCX75112P223251 FB1  25.0  580  drum 500m (+/-5%) 
Armoured St. Steel braid  OCX75112P22325 1SA1  27.0  620  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


CCTV cable 75Ohm coax 2xRG11 2P 2C SHF1 Fire Resistant

   

 

 

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +80 °CBend minimum : 20 times O.D

Design

Coaxial 2 x 75Ohm RG11

Inner conductor : stranded tinned copper 7×0.40mm
Dielectric : PE + Silicone Ø 7.25 ± 0.18 mm
Braid : bare copper, coverage 97%
Wrapping : non-migrating polyester tape
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen Ø 10.3 ± 0.20 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 20.5 Ω/km R
Resistance braid : 4.5 Ω/km
Attenuation @ 500MHz : 15.5 dB/100m
Attenuation @ 1000MHz : 23.4 dB/100m
Return Loss @ 900MHz : > 20.0 dB
Screening effectiveness : > 25.0 dB

2 pairs AWG22

Conductor : stranded tinned copper AWG22/7 (0.88mm2)
Insulation : Mica+XLPE or silicon (nominal Ø 3.00mm)
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.3mm, colour coded (1.Black 2.Blue)
Resistance of conductor @ 20°C :≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage :  1000 V DC x 1 minute

Power, 2 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : Mica+XLPE or silicon nominal Ø 3.5mm, colour coded (1.Black, 2.Red, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 7.98 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): : SHF1 thermoplastic compound LSZH, Ø 17.5mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OCX752112P223251 – IEC60331-23 IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire braid, coverage ≥80% (alternatives : Bronze braid, Stainless steel braid)
Outer jacket : SHF1 thermoplastic compound LSZH, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC7511P223251F1 – IEC60331-23 IEC60332-3-24 – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Fire resistant : IEC 60331
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OCX752112P223251  26.0  780  drum 500m (+/-5%) 
Armoured GSWB  OCX752112P223251F21  29.0  950  drum 500m (+/-5%) 
Armoured GSWA  OCX752112P223251 FA1  30.0  1100  drum 500m (+/-5%) 
Armoured Bronze braid  OCX752112P223251 FB1  29.0  950  drum 500m (+/-5%) 
Armoured St. Steel braid  OCX752112P22325 1SA1  29.0  980  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


CCTV cable 75Ohm coax 2xRG11, 2xSignal, 2xPower SHF1 Armoured

 

   

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -40 to +80 °CBend minimum : 20 times O.D

 

Design

Coaxial 2 x 75Ohm RG11

Inner conductor : stranded tinned copper 7×0.40mm
Dielectric : polyethylene Ø 5.25 ± 0.18 mm
Braid : bare copper, coverage 97%
Wrapping : non-migrating polyester tape
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen Ø 10.3 ± 0.20 mm
Velocity : 67%
Capacitance : 67 pF/m
Resistance conductor : 20.5 Ω/km R
Resistance braid : 4.4 Ω/km
Attenuation @ 1000MHz : 23.4 dB/100m
Attenuation @ 3000MHz : 50.1 dB/100m
Return Loss @ 3000MHz : > 20.0 dB
Screening effectiveness : > 20.0 dB

Signal, 2 pairs AWG22

Conductor : stranded tinned copper AWG22/7 strands
Insulation : polyethylene nominal Ø 2.55
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.3mm, colour coded (1.Black 2.Blue)
Resistance of conductor @ 20°C :≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage :  1000 V DC x 1 minute

Power, 3 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.0mm, colour coded (1.Black, 2.Red, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 7.98 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version) : SHF1 thermoplastic compound LSZH, Ø 17.5mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC7511P223251 – LSZH IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire braid, coverage ≥80% (alternatives : Bronze braid, Stainless steel braid)
Outer jacket : SHF1 thermoplastic compound LSZH, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC7511P223251F1 – LSZH IEC60332-3-24 – lot + m

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OC752112P223251  26.0  drum 500m (+/-5%) 
Armoured GSWB  OC752112P223251F21  29.0  950  drum 500m (+/-5%) 
Armoured GSWA  OC752112P223251 FA1  30.0  1100  drum 500m (+/-5%) 
Armoured Bronze braid  OC752112P223251 FB1  29.0  950  drum 500m (+/-5%) 
Armoured St. Steel braid  OC752112P22325 1SA1  29.0  980  drum 500m (+/-5%) 

 

 

 

Other standards of reference

 

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. 


CCTV cable 75Ohm coax 2xRG59, 2 Pairs, 2 cores 2.5 SHF1 Armoured

   

 

 

Store at : -10 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 x O.D.
Operate at : -35 to +80 °CBend minimum : 25 x O.D.

Design

2 x 75Ohm RG59

Inner conductor : solid bare copper wire Class 1 0.58mm
Dielectric : polyethylene nominal Ø 3.70
Braid : bare copper, coverage ≥95%
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 6.15 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 154 ± 5 Ω/km
Resistance braid : 9 ± 3 Ω/km
Attenuation @ 500MHz : 24.8 dB/100m
Attenuation @ 1000MHz : 35.6 dB/100m
Attenuation @ 3000MHz : 67.7 dB/100m
Return Loss @ 3000MHz : 
> 14.0 dB

Signal, 2 pairs AWG24

Conductor : stranded tinned copper AWG24/7 strands
Insulation : polyethylene nominal thickness 0.40mm
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.8mm, colour coded (1.Black 2.Grey)
Resistance of conductor @ 20°C : 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage :  1000 V DC x 1 minute

Power, 2 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : ≥ 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): : thermoplastic compound LSZH SHF1, nom. thick. 0.80mm, black
Marking : APS Finland – ww/yy – COMPOSITE CABLE OC752592P243251 – SHF1 IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire braid, coverage ≥85% (Alternatives : Bronze braid, Tinned Copper braid, Stainless steel wire)
Outer jacket : thermoplastic compound LSZH SHF1, nom. thickness 1.50mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE – P/N – SHF1 IEC60332-3-24 – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO

 

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OC752592P243251  16.5  420  drum 500m (+/-5%) 
Armoured GSWB  OC752592P24325HF1  19.6  580  drum 500m (+/-5%) 
Armoured GSWA  OC752592P24325HA1  21.0  630  drum 500m (+/-5%) 
Armoured Bronze braid  OC752592P24325HB1  19.6  580  drum 500m (+/-5%) 
Armoured St. Steel braid  OC752592P24325HS1  19.6  620  drum 500m (+/-5%) 

 

 

 

Other standards of reference

 

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. 

 

 

 

 

 

 


CCTV cable 75Ohm coax RG11 Signal 2 pairs Power 3 cores SHF1

 

   

 

 

Store at: -40 to +70 °C
Install at: -10 to +50 °CBend minimum: 20 times O.D.
Operate at: -40 to +80 °CBend minimum: 20 times O.D.

Design

Coaxial, 75Ohm RG11

Inner conductor : stranded tinned copper 7×0.40mm
Dielectric : polyethylene Ø 5.25 ± 0.18 mm
Braid : bare copper, coverage 97%
Wrapping : non-migrating polyester tape
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen Ø 10.3 ± 0.20 mm
Velocity : 67%
Attenuation : @ 1000MHz 23.4 dB/100m
Capacitance : 67 pF/m
Attenuation : @ 3000MHz 50.1 dB/100m
Resistance conductor : 20.5 Ω/km
Return Loss : @ 3000MHz > 20.0 dB
Resistance braid : 4.4 Ω/km
Screening effectiveness : > 20.0 dB

Signal, 2 pairs AWG22

Conductor : stranded tinned copper AWG22/7 strands
Insulation : polyethylene nominal Ø 2.55
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.3mm, colour coded (1.Black 2.Bue)
Resistance of conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute

Power, 3 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.0mm, colour coded (1.Black, 2.Red, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 7.98 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version) : SHF1 thermoplastic compound LSZH, Ø 17.5mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC7511P223251 – LSZH IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire armour, coverage ≥80% (alternatives : Bronze braid, Stainless steel braid)
Outer jacket : SHF1 thermoplastic compound LSZH, nom. Ø 25.0mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC7511P223251F1 – LSZH IEC60332-3-24 – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OC75112P223251  17.5  480  drum 500m (+/-5%) 
Armoured GSWB  OC75112P223251F21  25.0  580  drum 500m (+/-5%) 
Armoured GSWA  OC75112P223251FA1  27.0  620  drum 500m (+/-5%) 
Armoured Bronze braid  OC75112P223251FB1  25.0  580  drum 500m (+/-5%) 
Armoured St. Steel braid  OC75112P223251SA1  27.0  620  drum 500m (+/-5%) 

 

Other standards of reference

 

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. 


CCTV cable 75Ohm coax RG11 Signal, 2 pairs, 3 Power cores LSZH

 

   

 

 

Store at : -40 to +70 °C
Install at :-10 to +50 °C, Bend minimum : 20 times O.D.

Operate at : -40 to +80 °C, Bend minimum : 20 times O.D.

Design

Coaxial, 75Ohm RG11

Inner conductor : stranded tinned copper 7×0.40mm
Dielectric :
polyethylene Ø 7.25 ± 0.18 mm
Braid :
bare copper, coverage 97%
Wrapping :
non-migrating polyester tape
Sheath :
non-corrosive thermoplastic compound, Low Smoke Zero Halogen Ø 10.3 ± 0.20 mm
Velocity :
67%
Capacitance :
67 pF/m
Resistance conductor :
20.5 Ω/km
Resistance braid :
4.4 Ω/km
Attenuation :
@ 1000MHz 23.4 dB/100m
Attenuation :
@ 3000MHz 50.1 dB/100m
Return Loss :
@ 3000MHz > 20.0 dB
Screening effectiveness :
> 20.0 dB

Signal, 2 pairs AWG22

Conductor : stranded tinned copper AWG22/7 Insulation : polyethylene nominal Ø 2.55
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.3mm, colour coded (1.Black 2.Bue)
Resistance of conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute

Power, 3 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 4.0mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : ≤ 7.98 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with llers and wrapping
Inner jacket (outer for unarmoured version) : SHF1 thermoplastic compound LSZH, Ø 17.5mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE “PN” – SHF1 IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire braid, coverage ≥80% (alternatives : Bronze braid, Stainless steel braid)
Outer jacket : SHF1 thermoplastic compound LSZH, nom. Ø 25.0mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE “PN” – SHF1 IEC60332-3-24 – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OC75112P22325Z 17.5  480  drum 500m (+/-5%) 
Armoured GSWB  OC75112P22325ZF21  25.0  580  drum 500m (+/-5%) 
Armoured GSWA  OC75112P22325ZFA1  27.0  620  drum 500m (+/-5%) 
Armoured Bronze braid  OC75112P22325ZFB1  25.0  580  drum 500m (+/-5%) 
Armoured St. Steel braid  OC75112P22325ZSA1  27.0  620  drum 500m (+/-5%) 

 

 

 

Other standards of reference

 

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. 

 

 

 

 

 

 

 


CCTV cable 75Ohm coax RG59, Signal 2 pairs, Power 3×2.5, SHF1

   

 

Store at : -10 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 x O.D.
Operate at : -34 to 80 °CBend minimum : 25 x O.D.

Design

Coaxial, 75Ohm RG59

Inner conductor : solid bare copper wire Class 1 0.58mm
Dielectric : polyethylene nominal Ø 3.70
Braid : bare copper, coverage ≥95%
Sheath : non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 6.15 mm
Velocity : 66%
Capacitance : 67 pF/m
Resistance conductor : 154 ± 5 Ω/km
Resistance braid : 9 ± 3 Ω/km
Attenuation : @ 500MHz 24.8 dB/100m
Attenuation : @ 1000MHz 35.6 dB/100m
Attenuation : @ 3000MHz 67.7 dB/100m
Return Loss @ 3000MHz > 14.0 dB
 

Signal, 2 pairs AWG24

Conductor : stranded tinned copper AWG24/7 strands
Insulation : polyethylene nominal thickness 0.40mm
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.8mm, colour coded (1.Black 2.Grey)
Resistance of conductor @ 20°C : 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute

Power, 3 cores 2.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.0mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): SHF1 thermoplastic compound, nom. thickness 0.80mm, black colour
Marking : APS Finland – ww/yy – COMPOSITE CABLE OC75592P24325H – SHF1 IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire braid, coverage ≥85% (Alternatives : Bronze braid, Stainless steel braid)
Outer jacket : non-corrosive thermoplastic compound, SHF1, nom. thickness 1.50mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE OC75592P24325HF2H – SHF1 IEC60332-3-24 – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Oil resistant : intermittent splash – permanent resistance available upon request
Water penetration : NO

 

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging   
Unarmoured  OC75592P243251  17.0  380  drum 500m (+/-5%) 
Armoured GSWB  OC75592P243251F21  22.0  480  drum 500m (+/-5%) 
Armoured GSWA  OC75592P243251FA1  24.0  500  drum 500m (+/-5%) 
Armoured Bronze braid  OC75592P243251FB1  22.0  480  drum 500m (+/-5%) 
Armoured St. Steel braid  OC75592P243251SA1  24.0  540  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


CCTV cable 75Ohm coax RG59, Signal 2 pairs, Power 3×2.5, SHF2

   

 

Store at : -10 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 x O.D.
Operate at : -40 to +80 °CBend minimum : 25 x O.D.

Design

Coaxial, 75Ohm RG59

Inner conductor : solid bare copper wire Class 1 0.58mm
Dielectric : polyethylene nominal Ø 3.70
Braid :
bare copper, coverage ≥95%
Sheath :
non-corrosive thermoplastic compound, Low Smoke Zero Halogen nominal Ø 6.15 mm
Velocity :
66%
Capacitance :
67 pF/m
Resistance conductor : 
154 ± 5 Ω/km
Resistance braid : 
9 ± 3 Ω/km
Attenuation : 
@ 500MHz 24.8 dB/100m
Attenuation : @ 1000MHz 35.6 dB/100m
Attenuation :
 @ 3000MHz 67.7 dB/100m
Return Loss : 
@ 3000MHz > 14.0 bB

Signal, 2 pairs AWG24

Conductor : stranded tinned copper AWG24/7 strands
Insulation : polyethylene nominal thickness 0.40mm
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.8mm, colour coded (1.Black 2.Grey)
Resistance of conductor @ 20°C : 90 Ω/km
Insulation resistance @ 20°C : ≥ 1000 MΩ x km
Test Voltage : 1000 V DC x 1 minute

Power, 3 cores 1.5mm2

Conductor : stranded tinned copper 2.5mm2
Insulation : cross linked polyethylene nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C : 8.21 Ω/km
Insulation resistance @ 20°C : ≥ 5000 MΩ x km
Test Voltage : 2000 V AC x 1 minute

Assembling

Cable core : coaxial, signal and power elements stranded together into a compact core, with fillers and wrapping
Inner jacket (outer for unarmoured version): crosslinked thermoplastic compound, LSZH SHF2, nom. thick. 0.80mm, black
Marking : APS Finland – ww/yy – COMPOSITE CABLE OC75592P243252 – SHF2 IEC60332-3-24 – lot + m

Armoured version

Armour : galvanized steel wire braid, coverage ≥85% (Alternatives : Bronze braid, Tinned Copper braid, Stainless steel wire)
Outer jacket : crosslinked thermoplastic compound, LSZH SHF2, nom. thickness 1.50mm, black colour
Marking : APS Finland – ww/yy – ARMOURED COMPOSITE CABLE – P/N – SHF2 IEC60332-3-24 – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC60092-360
Oil resistant : IEC60811
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

 

 

Ordering and delivery information

  Cable type  P/N  O.D [mm]  Weight [kg/km]  Packaging 
Unarmoured  OC75592P243252  16.0  380  drum 500m (+/-5%) 
Armoured GSWB  OC75592P24325HF2  21.0  480  drum 500m (+/-5%) 
Armoured GSWA  OC75592P24325HA2  23.0  500  drum 500m (+/-5%) 
Armoured Bronze braid  OC75592P24325HB2  23.0  480  drum 500m (+/-5%) 
Armoured St. Steel braid  OC75592P24325HS2  24.0  540  drum 500m (+/-5%) 

 

 

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 series Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. 


75 Ohm Coaxial cable RG6 CCS double screen PVC

 

Installation Features

Store at  -10 to +50 °C
Install at  -10 to +50 °C, Bend minimum : 20 times O.D.
Operate at : -0 to +60 °CBend minimum : 20 times O.D.
Pull maximum : 100N

 

Design

Conductor :  solid CCS 1.02mm
Dielectric :  foam PE nominal Ø 4.60mm
Screen 1 :  bonded AL/P nominal Ø 4.75mm
Screen 2 :  Aluminium wire braid nominal coverage 60%

Jacket : black PVC material nominal Ø 6.86mm
Marking :  APS Finland – ww/yy – 75 Ohm CATV RG6 CCS – P/N CCS6AB6VKB3 – lot – meter

 

Environmental properties and Fire Performances

Flame retardant : IEC60332-1-2

 

Electrical Characteristics

Characteristic impedance (Ohm) 75+/-3
Capacitance (pF/m) 52+/-2
Velocity of Propagation (%) 85.0
Return Loss (dB) 5-1000MHz ≥22

Frequency Attenuation
db/100ft
Attenuation
dB/100 meter
55 1.6 5.2
187 2.8 9.3
211 3.1 10
400 4.1 13.5
500 4.6 15.0
750 5.6 18.5
860 6.1 20.0
1000 6.6 21.5

 

Recommended connectivity

BNC connectors : APS BNC75

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


CCTV Composite cable Coax 75Ω RG6, Signal 2PR AWG22, Power 4×2,5mm2 MUD

      

Installation Features

Store at  -10 to +70 °C
Install at  -10 to +50 °C
Operate at : -20 to +90 °C
Bend minimum : 20 times O.D.
Bend minimum : 20 times O.D.
Pull maximum : 1500N

 

Design

Coaxial RG6
Conductor : bare copper 1×0.72mm
Insulation : polyethylene
Screen :  double tinned copper braid coverage 95%
Jacket : Low Smoke Zero Halogen material
Characteristic impedance : 75 Ω
Velocity :  66%

Signal 2 pairs AWG22 
Conductor :  Tinned copper 19×0.15mm
Insulation :  PVC. Colour code : 1.White, 2.Black.
Pairing : 2 conductors stranded together into a pair
Screen :  Aluminium/polyester tape.
Outer jacket :  Low Smoke Zero Halogen material (colour Black and Grey)

Power 4 conductors 2.5mm², 300VAC
Conductor :  bare copper 50×0.25mm
Insulation :  
XLPE HF FR Polyolefin. Colour code : 1. Blue  2. Brown  3. Black  4. Green/Yellow.

Assembling
Cable core :  1 coaxial, 2 x signal, 4 x power stranded together with fillers
Screen :  Tinned Copper wire braid, min. coverage 80%.
Inner jacket :  Low Smoke Zero Halogen material
Armour :  Galvanized Steel Wire, coverage 85%
Outer jacket :  Halogen free SHF-MUD PUR compound
Marking :  APS Finland – ww/yy – CCTV cable RG6 – 2 PR AWG22 – 4×2.5mm² – P/N OC7562P22425HAH – LSZH SHF +90°C – CE – lot – meter

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2
Halogen acid gas : IEC 60754-1, IEC 60754-2
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Ozone resistant : IEC 11801
Weather resistant : IEC 11801
Oil resistant :  IEC 11801
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

Ordering and delivery information

P/N : OC7562P22425HAU
Outer diameter :  24.4 ± 0.75mm
Weight :
 620 kg/km

Delivery length : 500m ± 10%

 

Standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 Communication cables – Specifications for test methods
MIL-C-17 General specification for radio frequency coaxial cables
IEC61196-1 Coaxial communication cables
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 Engineered by APS Team

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


CCTV Composite cable Fire Resistant 4xFO, Power 3×1,5mm2, SHF2-MUD

      

Standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 Communication cables – Specifications for test methods
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 General specifications for optical fibre cables

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +50 °C, bend minimum 20 times O.D.
Operate at : -40 to +90 °C, bend minimum : 20 times O.D.
Pull maximum : 1000N

 

Design

 

Fiber Optic, 4 cores
Fiber: 125/250μm SM or MM (see Fiber Characteristics datasheets)
Buffer: PBTP tube nominal diam 1.8mm filled with jelly
Colour code: 1.Natural  2.Red  3.Green  4.Yellow
Fire barrier : mica tape
Protection: Glass yarns (alternatively aramide yarns)
Jacket: LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 4.0mm

 

Power 3 conductors 1.5mm²

Conductor :  stranded tinned copper 1.5mm2
Insulation :  cross linked LSZH material type G10, nominal Ø 3.0mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C :  12.1 Ω/km
insulation resistance @ 20°C :  ≥ 5000 MΩ x km
Test Voltage :  2000 V AC x 1 minute

 

Assembling
Cable core :  power and fiber elements stranded together and wrapped by synthetic tape
Jacket :  non-corrosive thermoplastic compound, LSZH, nom. Ø 11.0mm, black
Armour :  galvanised steel, tinned copper or bronze braid, coverage ≥85%
Outer jacket : non-corrosive thermoset compound LSZH SHF2-MUD, nom. Ø 16.0mm, black colour
Marking (armoured version): 
APS Finland – ww/yy – FIRE RESISTANT GSWB ARMOURED COMPOSITE CABLE 4xOS2 + 3×1.5mm2 – OC3254xxXHooU – MUD NEK606 IEC60331 IEC60332-3-22 Cat.A – lot – CE + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases :  IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas :  IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission :  IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Fire resistant :  IEC60331
Ozone resistant :  IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 :  IEC 60092-360
Oil resistant :  IEC60811, IRM 903
MUD resistant :  NEK606:2009, IEC60092-360
Water absorption :  IEC60811-1-3
UV resistant :  IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact :  CSA C22.2

 

Ordering and delivery information

Cable type P/N O.D [mm] Weight [kg/km] Packaging
Armoured GSWB OC3154xxXHF2U 16.8 500 500m/1640ft drum (+/-5%)
Armoured GSWA OC3154xxXHFAU 16.8 500 500m/1640ft drum (+/-5%)
Armoured Bronze OC3154xxXHFBU 16.8 480 500m/1640ft drum (+/-5%)
Armoured Tinned Copper OC3154xxXHFTU 16.8 450 500m/1640ft drum (+/-5%)

XX =  fiber type = OS2 = S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4.

 Engineered by APS Team

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


CCTV Composite cable Fire Retardant 4xFO, 2 Pairs AWG24, 3×2.5mm2, LSZH

      

Standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 Communication cables – Specifications for test methods
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 General specifications for optical fibre cables

 

 

 

Installation Features

Store at  -10 to +70 °C
Install at  -10 to +50 °C, bend minimum 20 times O.D.
Operate at : -35 to +80 °C, bend minimum : 20 times O.D.
Pull maximum : 5000N

 

Design

Fiber Optic, 4 cores
Fiber: 125/250μm SM or MM (see Fiber Characteristics datasheets)
Buffer: PBTP tube nominal diam 1.8mm filled with jelly
Colour code: 1.Natural  2.Red  3.Green  4.Yellow
Protection: Glass yarns (alternatively aramide yarns)
Jacket: LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 3.5mm 

Signal 2 pairs AWG24
Conductor
:  stranded tinned copper AWG24/7 strands

Insulation :  polyethylene nominal Ø 1.50
Assembling : no 2 insulated conductors colour coded (1.White, 2.Black) stranded together into a pair.
Screen : aluminium/polyester tape 100% coverage with tinned copper drain wire
Sheath : non-corrosive thermoplastic compound, LSZH, nom. Ø 4.4mm, colour coded (1.Black 2.Bue)
Resistance of conductor @ 20°C :  ≤ 90 Ω/km
Insulation resistance @ 20°C :  
≥ 1000 MΩ x km 
Test Voltage :  
1000 V DC x 1 minute

Power 3 conductors 2.5mm²
Conductor :  stranded tinned copper 2.5mm2
Insulation :  XLPE, nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C :  ≤ 7.98 Ω/km
insulation resistance @ 20°C :  ≥ 1GΩ x km
Test Voltage :  2000V AC x 1 minute
Operating Voltage :  300/500V 

Assembling
Cable core : optical fiber, signal and power elements stranded together into a compact core, with fillers and wrapping where necessary.

Jacket :  LSZH thermoplastic compound, Ø 14.5mm, black colour 
Marking : APS Finland – ww/yy  –  CCTV COMPOSITE CABLE 4x “fiber type” 2 PR AWG24  3×2.5mm²  –  OC4S22P24325H  –  LSZH IEC60332-3-24 Cat.C  –  lot + m 

 

 

Armoured version  
     Armour : galvanized steel wire armour, coverage ≥85% (alternatives : Bronze braid, Stainless steel braid) 
     Outer jacket : LSZH thermoplastic compound, nom. Ø 18.5mm, black colour 
     Marking : APS Finland – ww/yy – ARMOURED CCTV COMPOSITE CABLE 4x “fiber type” 2 PR AWG24  3×2.5mm²  –  P/N  –  LSZH IEC60332-3-24 Cat.C  –  lot + m 

 

Environmental properties and Fire Performances

Degree of acidity of gases :  IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas :  IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission :  IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-24 Cat.C 

 

Ordering and delivery information

Cable type P/N O.D [mm] Weight [kg/km] Packaging
Unarmoured OC4xx2P24325H 14.5 380 drum 500m (+/-5%)
Armoured GSWB OC4xx2P24325HFH 18.5 500 drum 500m (+/-5%)
Armoured GSWA OC4xx2P24325HAH 18.5 500 drum 500m (+/-5%)
Armoured Bronze braid OC4xx2P24325HBH 18.5 500 drum 500m (+/-5%)
Armoured St. Steel braid OC4xx2P24325HSH 18.5 500 drum 500m (+/-5%)

XX =  fiber type = OS2 = S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4.

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


CCTV Composite cable Fire Retardant 4xFO, Power 3×2.5mm2, SHF2-MUD, Reinforced

      

Standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units.
CEI EN 50289 Communication cables – Specifications for test methods
EN 50290-2-23 Insulation materials for telecommunication cables
IEC 60811 Insulating and sheathing materials of electric cables – Test method
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 General specifications for optical fibre cables

 

Installation Features

Store at  -40 to +70 °C
Install at  -10 to +50 °C, bend minimum 20 times O.D.
Operate at : -40 to +90 °C, bend minimum : 20 times O.D.
Pull maximum : 5000N

 

Design

Fiber Optic, 4 cores
Fiber: 125/250μm SM or MM (see Fiber Characteristics datasheets)
Buffer: PBTP tube nominal diam 1.8mm filled with jelly
Colour code: 1.Natural  2.Red  3.Green  4.Yellow
Protection: Glass yarns (alternatively aramide yarns)
Jacket: LSZH Orange, nominal thickness 0.7mm, nominal outer Ø 4.0mm

Power 3 conductors 2.5mm²
Conductor :  stranded tinned copper 2.5mm2
Insulation :  XLPE, nominal Ø 3.5mm, colour coded (1.Blue, 2.Brown, 3.Green/Yellow)
Conductor resistance @ 20°C :  ≤ 8.21 Ω/km
insulation resistance @ 20°C :  ≥ 1GΩ x km
Test Voltage :  2000V AC x 1 minute
Operating Voltage :  300/500V 

Assembling
Cable core :  3 power conductors and 1 fiber element stranded together into a compact core
Screen :  tinned copper wire braid (coverage ≥80%)
Wrapping :  synthetic tape
Reinforcing :  double layer of aramide yarns
Inner jacket :  non-corrosive thermoplastic compound, LSZH, nom. Ø 13.0mm, black
Armour :  galvanised steel, tinned copper or bronze braid, coverage ≥85%
Outer jacket : non-corrosive thermoset compound LSZH SHF2-MUD, black colour
Marking (armoured version): 
APS Finland – ww/yy – ARMOURED REINFORCED COMPOSITE CABLE 4x… + 3×2.5mm2 – P/N – MUD NEK606  IEC60332-3-22 Cat.A – lot – CE + meter

 

Environmental properties and Fire Performances

Degree of acidity of gases :  IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas :  IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission :  IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas :  EN50305 9.2
Flame retardant :  IEC 60332-1-2
Fire retardant :  IEC 60332-3-22 Cat.A
Ozone resistant :  IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 :  IEC 60092-360
Oil resistant :  IEC60811, IRM 903
MUD resistant :  NEK606:2009, IEC60092-360
Water absorption :  IEC60811-1-3
UV resistant :  IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact :  CSA C22.2

 

Ordering and delivery information

Cable type P/N O.D [mm] Weight [kg/km] Packaging
Armoured GSWB OC3254xxKSHF2U 19.8 590 500m/1640ft drum (+/-5%)
Armoured GSWA OC3254xxKSHFAU 19.8 590 500m/1640ft drum (+/-5%)
Armoured Bronze OC3254xxKSHFBU 19.8 580 500m/1640ft drum (+/-5%)
Armoured Tinned Copper OC3254xxKSHFTU 19.8 550 500m/1640ft drum (+/-5%)

XX =  fiber type = OS2 = S2, OM1=M1, OM2=M2, OM3=M3, OM4=M4.

 Engineered by APS Team

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

AP Solutions Oy – www.aps-finland.fi – info@apsolutions.fi