Arctic Grade CAN Bus cable 1&2 pairs 0.75mm SHF2

    

 

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : Stranded bare copper 24×0.20 (0.75mm2)
Insulation : Cellular polyolefin Ø2.95mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue
Screen on pair : Aluminium/polyester tape (100%)
Grounding wire : Tinned copper 24×0.20 (0.75mm2) polyolefin insulated (nominal Ø2.40mm). Colour yellow/green.
Assembling : One screened pair with one grounding wire with fillers, wrapped with fire barrier tape
Overall screen : tinned copper braid (coverage ≥80%)
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 12.0mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE CAN BUS Marine 1x2x0.75 +0.75mm SHF2 – IEC60332-3-22 Cat A – TK/lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1kV d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 26.0 Ω/km for bare copper / ≤ 26.7 Ω/km for bare coppe
Insulation resistance @ 20°C : ≥ 1GΩxkm (BUS conductor) / ≥ 10MΩxkm (earth conductor)
Nominal Capacitance @ 800Hz : 40 pF/m
Average characteristic impedance : 120 ± 10% @ 1MHz
Nominal attenuation : 13.2 dB/km @ 1MHz

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  OCBA1P075F2  12.0  225  drum 500m (+/-5%) 
2 pairs  OCBA2P075F2  12.0  255  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


Arctic Grade Profibus cable 1&2 pairs 0.35mm2 SHF2

 

    

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : Stranded bare copper 7×0.25 (0.35mm2 )
Insulation : Polyolefin Ø2.75mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Outer jacket : Black or purple Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 9,6mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE PROFIBUS MARINE …x2x0.35mm2 SHF2 – IEC60332-3-22 Cat.A – TK/lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1500V a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 55.0 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m
Characteristic impedance : 150 Ω ± 15 @ 1MHz

Nominal attenuation : 45 dB/km @ 16MHz
22 dB/km @ 4MHz
5 dB/km @ 38,4 KHz
3 dB/km @ 9,6 KHz
Baudrate : 9.6 kBits/s @ Max. 1200m
19.2 kBits / @ Max. 1200m
93.75 kBits/s @ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s @ Max. 400m
1.5 MBits /s @ Max. 200m
12 MBits /s @ Max. 100m

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  OPBA1P035F2  9.6  95  drum 500m (+/-5%) 
2 pairs  OPBA2P035F2  9.6  120  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.

                                

 

 

 


Arctic Grade RS422 cables up to 4 pairs, armoured, SHF2

 

    

 

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.10mm
Pair : no 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Asssembling : 1, 2 or 4 pairs assembled together into a compact core
Overall screen : aluminium/polyester tape (coverage 100%) with tinned copper drain wire 7×0.20mm.
Inner jacket : black Fire Retardant SHF1 material, LSZH (Ø 7.0mm)
Armour : galvanized steel, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE RS422 SHF2 ARMOURED CABLE … PAIRS 24AWG 100 OHM – IEC60332-3-22 Cat A – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 52 pF/m
Characteristic impedance : 100 ± 15 Ω @ 1MHz
Nominal attenuation : 28 dB/km @ 1MHz

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  ORS2A1P24Fx2  12.0  195  drum 500m (+/-5%) 
2 pairs  ORS2A2P24Fx2  12.0  195  drum 500m (+/-5%) 
4 pairs  ORS2A4P24Fx2  12.0  215  drum 500m (+/-5%) 


For armour replace x with “A” for Galvanized Steel Wire Braid, “T” for Tinned Copper Wire Braid, “B” for Bronze Wire Braid.

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 


Arctic Grade RS485 cables up to 4 pairs, armoured, SHF2

    

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

 

 

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.30mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : 1, 2 or 4 pairs assembled together into a compact core
Overall screen 1 : aluminium/polyester tape (coverage 100%) with stranded tinned copper drain wire 7×0.20mm.
Overall screen 2 : tinned copper braid (nominal coverage 85%)
Inner jacket : black Fire Retardant SHF1 material, LSZH (Ø 8.0mm)
Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE RS485 SHF2 ARMOURED CABLE … PAIRS 24AWG 100 OHM – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 42 pF/m
Characteristic impedance : 120 ± 15 Ω @ 1MHz
Nominal attenuation : 22 dB/km @ 1MHz

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  ORS5A1P24Fx2  12.2  200  drum 500m (+/-5%) 
2 pairs  ORS5A2P24Fx2  12.2  200  drum 500m (+/-5%) 
4 pairs  ORS5A4P24Fx2  12.2  220  drum 500m (+/-5%) 


For armour replace x with “A” for Galvanized Steel Wire Braid, “T” for Tinned Copper Wire Braid, “B” for Bronze Wire Braid.

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.

 


MOG CAN Bus 1&2 pairs stranded conductor 0.75mm, SHF2

 

     

 

Store at: -40 to +70 °C
Install at: -40 to +50 °CBend minimum: 15 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

 

Design

Conductor : Stranded bare copper 24×0.20 (0.75mm2)
Insulation : Cellular polyolefin Ø2.95mm
1 Pair : No 2 insulated conductors stranded together into a pair (Colour code : White/blue)
2 Pairs : No 4 insulated conductors stranded together into a star quad

Screen : Aluminium/polyester tape (100%)
Grounding wire : Tinned copper 24×0.20 (0.75mm2) polyolefin insulated (nominal Ø2.40mm). Colour yellow/green.
Assembling : One screened pair or quad with one grounding wire with fillers, wrapped with fire barrier tape
Overall screen : tinned copper braid (coverage ≥80%)
Outer jacket : Grey Fire Retardant and UV Resistant SHF1 material, LSZH (Ø 11.1mm)
Marking : APS Finland – ww/yy – CAN BUS Marine 1x2x0.75mm2 SHF2 – IEC60332-3-22 Cat A – TK/lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : YES – NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO – IEC 60331-25
Ozone resistant : YES – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : YES – IEC 60092-359:1987-03
Oil resistant : YES (oil, fuels and hydrocarbons) – IEC60811
MUD resistant : NO – NEK 606:2009
Water resistant : YES – IEC60502
Water penetration : NO – IEC 60794-1-2-F5-B
UV resistant : YES – ASTM-D-2565-92A

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair OCB1P075F2 11.0 210 500 m (+/-5%)
2 pairs (1 quad) OCB2P075F2 11.0 240 500 m (+/-5%)

 

 

 

Electrical characteristics

Operation voltage :  100V
Test voltage :  1kV d.c. for 1 minute
Resistance of the conductor @ 20°C :  ≤ 26.0 Ω/km for bare copper / ≤ 26.7 Ω/km for bare coppe

Insulation resistance @ 20°C :  ≥ 1GΩxkm (BUS conductor) / ≥ 10MΩxkm (earth conductor)
Nominal Capacitance @ 800Hz :  40 pF/m
Average characteristic impedance :  120 ± 10% @ 1MHz
Nominal attenuation :  13.2 dB/km @ 1MHz

 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 


MOG DeviceNet Thick, Data + Power, SHF1

    

 

Store at : -30 to +60 °C
Install at : -10 to +50 °CBend minimum: -40 to +80 °C 8 x O.D.
Operate at : -40 to +80 °CBend minimum : 15 x O.D.
Pull maximum : 100N

 

Design

 

Data Pair 1.3/3.8 (AWG15)
Conductor : stranded tinned copper wire, 19×0.25mm, nom. Ø 1.3mm
Insulation : PE, nom. Ø 3.8mm (colour code Blue/White)
Screen : Alu/PE laminated foil


Power Pair 1.7/2.7 (AWG18)
Conductor : stranded tinned copper wire, 19×0.25mm, nom. Ø 1.3mm
Insulation : PE, nom. Ø 3.8mm (colour code Red/Black)
Screen : Alu/PE laminated foil


Assembling : Data and power pair stranded together into a compact core, with fillers if necessary
Shield : Tinned copper wire braid (coverage 70%) with stranded copper drain wire.
Outer jacket : Fire Retardant, LSZH material SHF1. Colour according to customer’s request

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-24 Cat.C

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 + 1 pairs ODNT2DPS1 12.2 100 500 m (+/-5%)

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Max operating voltage: 300 V
Test voltage: 1500V a.c. for 1 minute (wire/wire/screen)
Conductor resistance: ≤ 22.6 Ω/km (Data)
                                       ≤ 11.7 Ω/km (Power)
Insulation resistance: ≥ 200MOhm*km
Nominal capacitance (wire/wire): 39 pF/m @ 800Hz @ 1 KHz
Characteristic impedance: 120 Ω ± 10% @ 1 MHz
Capacity unbalanced to ground: ≤ 3937 pF/0km

Typical attenuation
125 MHz      0.42 dB/100m 

500 MHz      0.81 dB/100m 
1000 MHz    1.31 dB/100m

 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 


MOG Profibus 1&2 pairs, Fire Resistant, Armoured, SHF2

     

 

 

Store at: -40 to +70 °C
Install at: -40 to +50 °CBend minimum: 20 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 150N

 

 

Design

Conductor : Solid or stranded bare copper 0.35mm2
Fire protection : fire resistant tape
Insulation : Polyolefin Ø 2.75mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Inner jacket : Black or purple Fire Retardant LSZH SHF1 material (Ø 8.6mm)
Armour : galvanized steel, tinned coppe or bronze wires braid (nominal coverage 85%)
Outer jacket : Black or purple Fire Retardant, LSZH and UV Resistant SHF2 material
Marking : APS Finland – ww/yy – ARMOURED FIRE RESISTANT PROFIBUS MARINE …x2x0.35mm2 LSZH SHF2 – IEC 60331-23 IEC60332-3-22 Cat.A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-1, IEC 61034-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-23 (Max changes in Impedance and Attenuation @ 4-16MHz : ±25%)
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811-404
UV resistant : ASTM-D-2565-99 (2008), 500 hours cycle 1, max change allowed in elongation after the test : 40%
Cold bend & impact : IEC 60092-350, CSA C22.2

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair OPBX1P035F1x2 12.6 220 500 m (+/-5%)
2 pairs OPBX2P035F1x2 12.6 230 500 m (+/-5%)

x = “A” for Galvanized Steel wire braid, “T” for Tinned Copper wire braid, “B” for Bronze wire braid.

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1000V d.c.
Resistance of the conductor @ 20°C : ≤ 55.0 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m Characteristic impedance : 150 Ω ± 15 @ 1MHz

Nominal attenuation : 45 dB/km @ 16MHz
22 dB/km @ 4MHz
5 dB/km @ 38,4 KHz
3 dB/km @ 9,6 KHz
Baudrate : 9.6 kBits/s @ Max. 1200m
19.2 kBits / @ Max. 1200m
93.75 kBits/s @ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s @ Max. 400m
1.5 MBits /s @ Max. 200m
12 MBits /s @ Max. 100m

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


MOG Profibus DP 1 &2 pairs stranded conductor 0.35mm2, SHF2

 

     

 

Store at: -40 to +70 °C
Install at: -40 to +50 °CBend minimum: 20 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

 

Design

Conductor : Stranded bare copper 7×0.25 (0.35mm2)
Insulation : Polyolefin Ø2.75mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Outer jacket : Black Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 8.6mm)
Marking : APS Finland – PROFIBUS MARINE …x2x0.35mm2 SHF2 – IEC60332-3-22 Cat.A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : YES – NES 713, CEI 20-37/7
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO – IEC 60331-25
Ozone resistant : YES – DIN VDE 0472 part 805 B
Weather resistant : YES – ASTM G 154, EN 11507
LSZH SHF2 : YES – IEC 60092-359:1987-03
Oil resistant : YES (oil, fuels and hydrocarbons) – IEC60811
MUD resistant : NO
Water resistant : YES – IEC60502
Water penetration : NO – IEC 60794-1-2-F5-B
UV resistant : YES – ASTM-D-2565-92A

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair OPB1P035F2 8.6 95 500 m (+/-5%)
2 pairs OPB2P035F2 8.6 110 500 m (+/-5%)

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1500V a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 55.0Ω/km

Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m 
Characteristic impedance : 150 Ω ± 15 @ 1MHz

Nominal attenuation : 45 dB/km @ 16MHz
22 dB/km @ 4MHz
5 dB/km @ 38,4 KHz
3 dB/km @ 9,6 KHz
Baudrate : 9.6 kBits/s @ Max. 1200m
19.2 kBits / @ Max. 1200m
93.75 kBits/s @ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s @ Max. 400m
1.5 MBits /s @ Max. 200m
12 MBits /s @ Max. 100m

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 

 

 

 

 


MOG Profibus DP 1&2 pairs stranded conductor 0.35mm2 Armoured SHF2

 

     

 

Store at: -40 to +70 °C
Install at: -40 to +50 °CBend minimum: 20 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

 

Design

Conductor : Stranded bare copper 7×0.25 (0.35mm2)
Insulation : Polyolefin Ø2.75mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Inner jacket : Black or purple Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 8.6mm)
Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : Black or purple Fire Retardant and UV Resistant SHF2 material, LSZH
Marking : APS Finland – ww/yy – ARMOURED PROFIBUS MARINE …x2x0.35mm2 SHF2 – IEC60332-3-22 Cat.A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : available upon request
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811
MUD resistant : available upon request
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair OPB1P035Fx2 12.0 135 500 m (+/-5%)
2 pairs OPB2P035Fx2 12.0 150 500 m (+/-5%)


x = “A” for Galvanized Steel wire braid, “T” for Tinned Copper wire braid, “B” for Bronze wire braid.

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1500V a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 55.0 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m Characteristic impedance : 150 Ω ± 15 @ 1MHz

Nominal attenuation : 45 dB/km @ 16MHz
22 dB/km @ 4MHz
5 dB/km @ 38,4 KHz
3 dB/km @ 9,6 KHz
Baudrate : 9.6 kBits/s @ Max. 1200m
19.2 kBits / @ Max. 1200m
93.75 kBits/s @ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s @ Max. 400m
1.5 MBits /s @ Max. 200m
12 MBits /s @ Max. 100m

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


MOG Profibus DP 1&2 pairs stranded conductor 0.35mm2, Armoured, MUD-Resistant NEK606

 

     

 

Store at: -40 to +90 °C
Install at: -40 to +50 °CBend minimum: 20 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

 

Design

Conductor : Stranded bare copper 7×0.25 (0.35mm2)
Insulation : Polyolefin Ø2.75mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Inner jacket : Black or purple Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 8.6mm) Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : Black or purple Fire Retardant and UV Resistant SHF2 material, LSZH, MUD Resistant
Marking : APS Finland – ww/yy – ARMOURED PROFIBUS MARINE …x2x0.35mm2 SHF2 MUD-Resistant NEK606- IEC60332-3-22 Cat.A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm) Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : available upon request
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811
MUD resistant : NEK606:2009, IEC60092-360
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair OPB1P035FxU 12.0 165 500 m (+/-5%)
2 pairs OPB2P035FxU 12.0 180 500 m (+/-5%)

x = “A” for Galvanized Steel wire braid, “T” for Tinned Copper wire braid, “B” for Bronze wire braid.

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1500V a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 55.0 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m

 

Nominal attenuation : 45 dB/km @ 16MHz
22 dB/km @ 4MHz
5 dB/km @ 38,4 KHz
3 dB/km @ 9,6 KHz
Baudrate : 9.6 kBits/s @ Max. 1200m
19.2 kBits / @ Max. 1200m
93.75 kBits/s @ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s @ Max. 400m
1.5 MBits /s @ Max. 200m
12 MBits /s @ Max. 100m

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


MOG Profibus DP 1&2 pairs stranded conductor 0.35mm2, SHF2 MUD NEK606

     

 

Store at: -40 to +70 °C
Install at: -40 to +50 °CBend minimum: 20 times O.D.
Operate at: -40 to +90 °CBend minimum: 10 times O.D.
Pull maximum: 100N

 

 

Design

Conductor : Stranded bare copper 7×0.25 (0.35mm2)
Insulation : Polyolefin Ø2,75mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Inner jacket : Black or purple Fire Retardant and UV Resistant material, LSZH (Ø 8.6mm)
Outer jacket : Black or purple Fire Retardant and UV Resistant, SHF2 and MUD Resistant material, LSZH (Ø 10.6mm)
Marking : APS Finland – ww/yy – PROFIBUS MARINE …x2x0.35mm2 SHF2 – IEC60332-3-22 Cat A – MUD Resistant NEK606 – TK/lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10μS/mm)
Halogen acid gas :  IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : available upon request
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-360
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair OPB1P035FU 10.6 145 500 m (+/-5%)
2 pairs OPB2P035FU 10.6 160 500 m (+/-5%)

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1500V a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 55.0 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m Characteristic impedance : 150 Ω ± 15 @ 1MHz

 

Nominal attenuation : 45 dB/km @ 16MHz
22 dB/km @ 4MHz
5 dB/km @ 38,4 KHz
3 dB/km @ 9,6 KHz
Baudrate : 9.6 kBits/s @ Max. 1200m
19.2 kBits / @ Max. 1200m
93.75 kBits/s @ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s @ Max. 400m
1.5 MBits /s @ Max. 200m
12 MBits /s @ Max. 100m

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.


MOG RS422 1,2,4 pairs Armoured SHF1

 

     

 

Store at : -40 to +70 °C
Install at : -40 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +90 °CBend minimum : 10 times O.D.
Pull maximum : 100N

 

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.10mm
Pair : no 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Asssembling : 1, 2 or 4 pairs assembled together into a compact core
Overall screen : aluminium/polyester tape (coverage 100%) with tinned copper drain wire 7×0.20mm.
Inner jacket : black Fire Retardant SHF1 material, LSZH (Ø 7.0mm)
Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : black Fire Retardant and UV Resistant SHF1 material, LSZH (nominal Ø 11.0mm)
Marking : APS Finland – ww/yy – RS422 SHF1 ARMOURED MARINE CABLE … PAIRS 24AWG 100 OHM – IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : upon request
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : upon request
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair ORS21P24FA1 10.0 180 500 m (+/-5%)
2 pairs ORS21P24FA1 10.0 180 500 m (+/-5%)
4 pairs ORS24P24FA1 11.0 200 500 m (+/-5%)

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C :  ≤  90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm Nominal Capacitance @ 800Hz : 52 pF/m
Characteristic impedance : 100 ± 15 Ω @ 1MHz
Nominal attenuation : 28 dB/km @ 1MHz

 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 


MOG RS485 1,2,4 pairs Armoured SHF1

 

    

 

Store at : -40 to +70 °C
Install at : -40 to +50 °C, Bend minimum : 15 times O.D.
Operate at : -40 to +70 °C, Bend minimum : 10 times O.D.
Pull maximum : 400N

 

 

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.30mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : 1, 2 or 4 pairs assembled together into a compact core
Overall screen 1 : aluminium/polyester tape (coverage 100%) with stranded tinned copper drain wire 7×0.20mm.
Overall screen 2 : tinned copper braid (nominal coverage 85%)
Inner jacket : black Fire Retardant SHF1 material, LSZH (Ø 8.0mm)
Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : black Fire Retardant and UV Resistant SHF1 material, LSZH (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – RS485 SHF1 ARMOURED MARINE CABLE … PAIRS 24AWG 100 OHM – IEC60332-3-22 Cat A – lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : upon request
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : upon request
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair ORS51P24FA1 11.2 180 500 m (+/-5%)
2 pairs ORS52P24FA1 11.2 190 500 m (+/-5%)
4 pairs ORS54P24FA1 12.0 230 500 m (+/-5%)

 

 

Electrical characteristics

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm Nominal Capacitance @ 800Hz : 42 pF/m
Characteristic impedance : 120 ± 15 Ω @ 1MHz
Nominal attenuation :  22 dB/km @ 1MHz

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 


MOG RS485 1,2,4 pairs Armoured SHF2 MUD NEK606

    

 

Store at : -20 to +70 °C
Install at : -20 to +50 °CBend minimum : 15 times O.D.
Operate at : -40 to +70 °CBend minimum : 10 times O.D.
Pull maximum : 400N

 

 

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.30mm
Pair : 2 insulated conductors stranded together into a pair.
Assembling : 1, 2 or 4 pairs assembled together into a compact core
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Overall screen 1 : aluminium/polyester tape (coverage 100%) with stranded tinned copper drain wire 7×0.20mm.
Overall screen 2 : tinned copper braid (nominal coverage 85%)
Inner jacket : black Fire Retardant LSZH material
Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage >80%)
Outer jacket : black Fire Retardant LSZH material type SHF2 MUD-Resistant
Marking : APS Finland – ww/yy – ARMOURED RS485 MARINE CABLE … PAIRS 24AWG 100 OHM – SHF2 MUD IEC60332-3-22 Cat.A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
Weather resistant : ASTM G 154, EN 11507
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2 (-40°C)

 

 

 

Ordering and delivery information

Pair count P/N O.D [mm] Weight [kg/km] Packaging
1 pair RS51P24FxU 10.0 140 500 m (+/-5%)
2 pairs RS52P24FxU 11.0 185 500 m (+/-5%)
4 pairs RS54P24FxU 11.5 205 500 m (+/-5%)

 

 

Electrical characteristics

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 42 pF/m
Characteristic impedance : 120 ± 15 Ω @ 1MHz
Nominal attenuation : 22 dB/km @ 1MHz

 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 

 