Arctic Grade CAN Bus cable 1&2 pairs 0.75mm SHF2

    

 

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : Stranded bare copper 24×0.20 (0.75mm2)
Insulation : Cellular polyolefin Ø2.95mm
Pair : No 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue
Screen on pair : Aluminium/polyester tape (100%)
Grounding wire : Tinned copper 24×0.20 (0.75mm2) polyolefin insulated (nominal Ø2.40mm). Colour yellow/green.
Assembling : One screened pair with one grounding wire with fillers, wrapped with fire barrier tape
Overall screen : tinned copper braid (coverage ≥80%)
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 12.0mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE CAN BUS Marine 1x2x0.75 +0.75mm SHF2 – IEC60332-3-22 Cat A – TK/lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1kV d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 26.0 Ω/km for bare copper / ≤ 26.7 Ω/km for bare coppe
Insulation resistance @ 20°C : ≥ 1GΩxkm (BUS conductor) / ≥ 10MΩxkm (earth conductor)
Nominal Capacitance @ 800Hz : 40 pF/m
Average characteristic impedance : 120 ± 10% @ 1MHz
Nominal attenuation : 13.2 dB/km @ 1MHz

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  OCBA1P075F2  12.0  225  drum 500m (+/-5%) 
2 pairs  OCBA2P075F2  12.0  255  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


Arctic Grade Cat.5e LAN cable S/FTP 4 pairs SHF2

 

    

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : stranded bare copper 7×0.20 AWG24 (0,22mm2)
Insulation : polyethylene
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen 1 : aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper braid coverage min. 60%
Outer jacket : grey Fire Retardant and UV Resistant SHF2 material, LSZH (nominal thickness 1.5mm, Ø 9.5mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE SFTP Flex 4x2x24AWG Cat.5e SHF2 – IEC60332-3-22 Cat A – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics

Test voltage : 700 Vrms (cond/cond and cond/screen) for 1 minute
Resistance of the conductor @ 20°C : ≤ 88 Ω/km
Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance : 52 pF/m (cond/cond)
Average characteristic impedance : 100 ± 5 Ω @ 100MHz

Frequency (MHz) : 1 4 10 16 20 31.5 62.5 100
Attenuation (dB/100m) 3.2 6.0 9.5 12.1 13.6 17.1 24.8 32.0
NEXT (dB) 65.3 56.3 50.3 47.2 45.8 42.9 38.4 35.3
ELFEXT (dB) 63.8 51.8 43.8 39.7 37.8 33.9 27.9 23.8
Return Loss 23.0 24.1 25.0 25.0 25.0 23.6 21.5 20.1

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
4 pairs  O5EASF4P24F2  9,5  100  500m or 1000m (±5%) 

 

 

Recommended connectivity

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ6S_

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1 Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1 Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1 Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2 Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 series Communication cables – Specifications for test methods
IEC 60811 Insulating and sheathing materials of electric cables – Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.

 

 


Arctic Grade Cat.6A LAN cable S/FTP 4 pairs SHF2

 

    

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid ce
Outer jacket : Grey Fire Retardant and UV Resistant SHF2 material, LSZH (nominal Ø 10.0mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE SFTP Flex 4x2x23AWG Cat.6A SHF2 – IEC60332-3-22 Cat A – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission :IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm
Nominal Capacitance @ 800÷1000MHz : 45 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ˂ 3mΩ/m @ 10MHz

Frequency (MHz) :  10  20  31,25  62,5  100  155  200  300  400  500 
Attenuation dB/100m (nominal)  1,8  3,3  5,4  7,4  9,6  13,9  17,5  22,4  24,8  30,7  35,9  40,2 
NEXT dB (nominal)  95  95  92  88  87  86  84  83  82  81  80  79 
ACR dB/100m (nominal)  93  92  87  81  77  72  66  61  57  50  44  39 
ELFEXT dB (nominal)  90  88  87  85  81  77  72  68  65  62  59  57 
Return Loss dB (nominal)  25  28  30  30  30  28  27  26  25  23  22  21 

 

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
4 pairs  O6AASF4P23F2  10,0  110  500m (+/-5%) 

 

 

Recommended connectivity

Keystone jack : KJ6ASTPNH
RJ45 plug : P456SAPS
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ6S_

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1 Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1 Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1 Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2 Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 series Communication cables – Specifications for test methods
IEC 60811 Insulating and sheathing materials of electric cables – Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. 


Arctic Grade Cat.7 LAN cable S/FTP 4 pairs SHF2

    

 

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

 

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown (IEC 708-1)
Screen 1 : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Screen 2 : tinned copper wire braid ce
Outer jacket : Grey Fire Retardant and UV Resistant SHF2 material, LSZH (nominal Ø 10.0mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE SFTP Flex 4x2x23AWG Cat.7 SHF2 – IEC60332-3-22 Cat A – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

Electrical characteristics (IEC 60811, EN 50288-4-2)

Test voltage : 1kV d.c. or 0.7kV a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 69,5 /km
Insulation resistance : ≥ 500 MΩxkm (100V-500V)
Nominal Capacitance @ 800÷1000MHz : 55 pF/m
Average characteristic impedance : 100 ± 5 Ω @ 100MHz
Transfer impedance : ≤15mΩ/m @ 1MHz, – ≤10mΩ/m @ 10MHz – ≤30mΩ/m @ 30MHz

Frequency (MHz) : 1 4 10 16 20 32.5 62.5 100 155 200 300 600
Attenuation dB/100m (typical) 2.2 3.8 5.9 7.4 8.4 10.5 15.3 18.1 23.2 26.6 33.3 50.1
NEXT dB (typical) 100 100 95 90 90 90 85 82 80 77 71 67
PS NEXT dB (typical) 95 95 90 86 80 80 80 75 70 68 66 62
ELFEXT dB (typical) 96 93 90 100 100 100 100 100 100 100 100
PS ELFEXT dB (typical) 98 90 98 105 90 90 90 90 90 90 90 90
Return Loss dB (typical) 35 31 38 32 32 31 27 34 28 25 23 21

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
4 pairs  O7ASF4P23F2  10,0  110  500m or 1000m (+/-5%) 

 

 

Recommended connectivity

Keystone jack : KJ6ASTPNH (Category 6A)
RJ45 plug : P457SAPS 
Panel : PPE24SU, OPPE24SU
Patchcords : PCMJ6S_

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
CEI EN 50288-1 Multi-element metallic used in analogue and digital communication and control : Generic Specification
CEI EN 50288-2-1 Setional specification for screened cables characterised up to 100MHz
CEI EN 50288-5-1 Setional specification for screened cables characterised up to 250MHz
CEI EN 50288-4-2 Setional speci cation for screened cables characterised up to 600MHz
CEI EN 50289 series Communication cables – Specifications for test methods
IEC 60811 Insulating and sheathing materials of electric cables – Test method
Standards EIA/TIA 568-C.2, ISO/IEC 11801, UL444, UL1581, UL1666
Applications 100Base-TX, 100Base-T, 100VG-AnyLAN, 1000Base-TX, ATM

 
Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


Arctic Grade Fiber Optic cable QFCI SHF2

    

 

Store at : -40 to +70 °C
Install at : -10 to +50 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 15 times O.D.
Pull maximum : 2000N
Crush maximum : 3000N/100mm
Impact maximum : 30J
Cable weight : 25

 

 

Design

Bare fiber : 250µm
Buffer : Loose tube (Ø2.2mm) filled with jelly, housing up to 12 fibers
Colour code : See table
Fire protection : A fire barrier is applied over every single tube housing fibers
Central member : Steel rope with LSZH sheath
Cable core : Loose tubes and fillers (when necessary) are stranded around the central member. The core is wrapped by a tape.
Inner sheath : Black SHF1 material 1.0mm thick. Nominal outer diameter 10.1mm.
Armour : Galvanized steel, bronze or tinned copper wire braid. Coverage ≥85%.
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (nominal O.D. 14.0mm) .
Marking : APS Finland ww/mm – ARCTIC GRADE Fiber Optic Cable QFCI “fiber count and type” – SHF2 IEC60332-3-22 Cat A – TK/lot + meter

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : IEC 60331-25
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Colour code of fibers

01 02 03 04 05 06 07 08 09 10 11 12
White Red Yellow Green Blue Grey Brown Black Violet Turquoise Orange Pink

 

Colour code of tubes

Tube Type A   Type B          
2 fibers 4 fibers 8 fibers 12 fibers 24 fibers 48 fibers
1 Red (12 fibers) Red (2 fibers) Red (2 fibers) Red (4 fibers) Red (4 fibers) Red (6 fibers) Red (12 fibers)
2 Green (24 fibers) Filler Green (2 fibers) Green (4 fibers) Green (4 fibers) Green (6 fibers) Green (12 fibers)
3 Natural (36 fibers) Filler Filler Filler Natural (4 fibers) Natural (6 fibers) Natural (12 fibers)
4 Natural (48 fibers) Filler Filler Filler Filler Natural (6 fibers) Natural (12 fibers)
5 – (*) – (*) – (*) – (*) – (*) – (*) – (*)
6 – (*) – (*) – (*) – (*) – (*) – (*) – (*)
(*) filler only in case of 6 elements design

 

 

Ordering and delivery information

  Fiber count  SM  OM1  OM2  OM3  OM4  Packaging 
OQFCIA02S22  OQFCIA02M12  OQFCIA02M22  OQFCIA02M32  OQFCIA02M42  drum 2000m (+/-5%) 
OQFCIA04S22  OQFCIA04M12  OQFCIA04M22  OQFCIA04M32  OQFCIA04M42  drum 2000m (+/-5%) 
OQFCIA08S22  OQFCIA08M12  OQFCIA08M22  OQFCIA08M32  OQFCIA08M42  drum 2000m (+/-5%) 
12  OQFCIA12S22  OQFCIA12M12  OQFCIA12M22  OQFCIA12M32  OQFCIA12M42  drum 2000m (+/-5%) 
24  OQFCIA24S22  OQFCIA24M12  OQFCIA24M22  OQFCIA24M32  OQFCIA24M42  drum 2000m (+/-5%) 
48  OQFCIA48S22  OQFCIA48M12  OQFCIA48M22  OQFCIA48M32  OQFCIA48M42  drum 2000m (+/-5%) 


Note : for bronze braid add “B” at the end of the P/N, for bronze braid add “T” at the end of the P/N.

 

Other standards of reference

IEC 60092-370 Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
DNV TAP 827.50/1 Type Approval Program – Optical Fibre Cables
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60793 General specifications for both multimode and single-mode optical fibres
IEC 60794 general specifications for optical fibres cables

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.


Arctic Grade Profibus cable 1&2 pairs 0.35mm2 SHF2

 

    

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : Stranded bare copper 7×0.25 (0.35mm2 )
Insulation : Polyolefin Ø2.75mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.Green/red 2.Blue/brown
Assembling : No 1 pair with fillers or no 2 pairs stranded together into a compact core
Screen : Aluminium/polyester tape (100%) with tinned copper braid (coverage ≥60%)
Outer jacket : Black or purple Fire Retardant and UV Resistant SHF2 material, LSZH (Ø 9,6mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE PROFIBUS MARINE …x2x0.35mm2 SHF2 – IEC60332-3-22 Cat.A – TK/lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics (IEC60092-350, IEC61784, IEC61158)

Operation voltage : 100V
Test voltage : 1500V a.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 55.0 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 30 pF/m
Characteristic impedance : 150 Ω ± 15 @ 1MHz

Nominal attenuation : 45 dB/km @ 16MHz
22 dB/km @ 4MHz
5 dB/km @ 38,4 KHz
3 dB/km @ 9,6 KHz
Baudrate : 9.6 kBits/s @ Max. 1200m
19.2 kBits / @ Max. 1200m
93.75 kBits/s @ Max. 1200m
187.5 kBits /s @ Max. 1000m
500 kBits /s @ Max. 400m
1.5 MBits /s @ Max. 200m
12 MBits /s @ Max. 100m

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  OPBA1P035F2  9.6  95  drum 500m (+/-5%) 
2 pairs  OPBA2P035F2  9.6  120  drum 500m (+/-5%) 

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.

                                

 

 

 


Arctic Grade RS422 cables up to 4 pairs, armoured, SHF2

 

    

 

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.10mm
Pair : no 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Asssembling : 1, 2 or 4 pairs assembled together into a compact core
Overall screen : aluminium/polyester tape (coverage 100%) with tinned copper drain wire 7×0.20mm.
Inner jacket : black Fire Retardant SHF1 material, LSZH (Ø 7.0mm)
Armour : galvanized steel, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE RS422 SHF2 ARMOURED CABLE … PAIRS 24AWG 100 OHM – IEC60332-3-22 Cat A – lot + m

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 52 pF/m
Characteristic impedance : 100 ± 15 Ω @ 1MHz
Nominal attenuation : 28 dB/km @ 1MHz

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  ORS2A1P24Fx2  12.0  195  drum 500m (+/-5%) 
2 pairs  ORS2A2P24Fx2  12.0  195  drum 500m (+/-5%) 
4 pairs  ORS2A4P24Fx2  12.0  215  drum 500m (+/-5%) 


For armour replace x with “A” for Galvanized Steel Wire Braid, “T” for Tinned Copper Wire Braid, “B” for Bronze Wire Braid.

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed. AP Solutions Oy reserves the right to make changes to the documents at any time, without prior notice.

 

 


Arctic Grade RS485 cables up to 4 pairs, armoured, SHF2

    

 

Store at : -20 to +70 °C
Install at : -20 to +70 °CBend minimum : 20 times O.D.
Operate at : -65 to +80 °CBend minimum : 20 times O.D.
Pull maximum : 50N

 

 

Design

Conductor : stranded tinned copper 7×0.20mm AWG24 (0.60mm, 0.22mm2)
Insulation : polyethylene Ø1.30mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Assembling : 1, 2 or 4 pairs assembled together into a compact core
Overall screen 1 : aluminium/polyester tape (coverage 100%) with stranded tinned copper drain wire 7×0.20mm.
Overall screen 2 : tinned copper braid (nominal coverage 85%)
Inner jacket : black Fire Retardant SHF1 material, LSZH (Ø 8.0mm)
Armour : galvanized steel wires, tinned copper or bronze wires braid (nominal coverage 85%)
Outer jacket : black Fire Retardant and UV Resistant SHF2 material, LSZH (nominal thickness 1.5mm)
Marking : APS Finland – ww/yy – ARCTIC GRADE RS485 SHF2 ARMOURED CABLE … PAIRS 24AWG 100 OHM – IEC60332-3-22 Cat A – lot + m

 

 

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Ozone resistant : IEC 60811-2-1
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC 60811, IRM 903
MUD resistant : upon request
Water absorption : IEC60811-1-3
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold Bend : CSA C22.2 (-65°C)
Cold Impact : CSA C22.2 (-55°C)

 

 

Electrical characteristics

Operation voltage : 100V
Test voltage : 2000V d.c. for 1 minute
Resistance of the conductor @ 20°C : ≤ 90 Ω/km
Insulation resistance @ 20°C : ≥ 1GΩxkm
Nominal Capacitance @ 800Hz : 42 pF/m
Characteristic impedance : 120 ± 15 Ω @ 1MHz
Nominal attenuation : 22 dB/km @ 1MHz

 

 

Ordering and delivery information

  Pair count  P/N  O.D [mm]  Weight [kg/km]  Packaging 
1 pair  ORS5A1P24Fx2  12.2  200  drum 500m (+/-5%) 
2 pairs  ORS5A2P24Fx2  12.2  200  drum 500m (+/-5%) 
4 pairs  ORS5A4P24Fx2  12.2  220  drum 500m (+/-5%) 


For armour replace x with “A” for Galvanized Steel Wire Braid, “T” for Tinned Copper Wire Braid, “B” for Bronze Wire Braid.

 

 

Other standards of reference

IEC 60092-370  Electrical installations in ships: Guidance on the selection of cables for telecommunication and data.
IEC 60092-360 Electrical installations in ships: Insulating and sheating materials for shipboard and offshore units. 
DNV TAP 827.50/2 Type Approval Program
ABS SVR Rules for building and classing. Steel Vessels.
ABS SMR Rules for building and classing. Steel vessels under 90 meters.
IEC 60811 Insulating and sheathing materials of electric cables – Test method

 

 

 

Every effort has been put so that this document is most reliable and free from errors. However, AP Solutions Oy cannot be considered responsible for any mistake in this document and users should consult AP Solutions Oy for any information needed.

 

AP Solutions Oy – www.aps-finland.fi – info@apsolutions.fi