AICI up to 24 fibers tight buffered, armoured metallic, SHF.

Store at : -40 to +70 °C
Install at : -10 to +50 °C
Bend minimum : 15 times O.D.
Operate at : -30 to +70 °C
Bend minimum : 10 times O.D.
Crush maximum : 2000N/100mm
Impact maximum : 25J

Design

Bare fiber : 250µm
Buffer : 900µm tight buffer
Colour code : See table
Cable core : up to 24 tight buffered fibers are stranded together. The core is filled with waterblocking glass yarns.
Inner sheath : black SHF1 material
Armour : galvanized steel, bronze or tinnerd copper wired braid. Coverage ≥80%.
Outer jacket : black SHF1 UV-Resistant material, LSZH
Marking : APS Finland – ww/mm – Fiber Optic Cable AICI “fiber count and type” – SHF1 IEC60332-3-22 Cat A – TK/lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : upon request
Weather resistant : upon request
LSZH SHF2 : upon request
Oil resistant : intermittent splash – permanent resistance available upon request
MUD resistant : upon request
Water absorption : IEC60502
Water penetration : IEC 60794-1-2-F5-B (inner core only)
UV resistant : IEC60811-2-1, ASTM-D-2565-92A

Marine:

Communication cables
Instrumentation cables
Composite cables
Fire Resistant cables

Onshore:

Communication cables
Instrumentation cables
Composite cables
Fire Resistant cables
High temperature cables

Offshore:

Communication cables
Instrumentation Cables
Composite cables
Fire Resistant cables
Deck and High-Lift Cables
Underwater cables
Arctic grade cables