50Ohm coaxial cable RG214U SHF1 unarmoured and armoured


Store at: -20 to +60 °C
Install at: 0 to +50 °C
Bend minimum: 10 times O.D.
Operate at: -30 to +70 °C
Bend minimum: 5 times O.D

Design

Conductor : stranded silvered copper 7×0.75mm
Dielectric : low density polyethylene Ø 7.25 ± 0.18 mm
Screen 1 : aluminium/poleysther/aluminium tape (width 29mm)
Screen 2 : silvered copper braid (coverage 94%)
Screen 3 : silvered copper braid (coverage 98%)
Outer jacket (inner jacket for armoured version): black Fire Retardant and UV Resistant SHF1 material, LSZH
Marking : APS Finland – ww/yy – RG214 MARINE SHF1 – 50 OHM – IEC60332-3-24 Cat.C – lot + meter

Armoured version is supplied with additional:
Armour : galvanized steel wire braid
Outer jacket : black Fire Retardant and UV Resistant SHF1 thermoplastic material, LSZH
Marking : APS Finland – ww/yy – RG214 MARINE SHF1 ARMOURED – 50 OHM – IEC60332-3-24 Cat.C – lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN 50305 9.2
Flame retardant : YES – IEC 60332-1-2
Fire retardant : YES – IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : NO
Weather resistant : NO
LSZH SHF2 : NO
Oil resistant : NO
MUD resistant : NO
Water resistant : NO
Water penetration : NO
UV resistant : YES – ASTM-D-2565-92A

Marine:

Communication cables
Instrumentation cables
Composite cables
Fire Resistant cables

Onshore:

Communication cables
Instrumentation cables
Composite cables
Fire Resistant cables
High temperature cables

Offshore:

Communication cables
Instrumentation Cables
Composite cables
Fire Resistant cables
Deck and High-Lift Cables
Underwater cables
Arctic grade cables