Cat.6A S/FTP 4 pairs AWG23/7 SHF2 NEK606 Armoured

Store at : -40 to +70 °C
Install at : -40 to +70 °C
Bend minimum : 20 times O.D.
Operate at : -40 to +80 °C
Bend minimum : 15 times O.D.
Pull maximum : 100N
Cable weight : 90 kg/km

Design

Conductor : Stranded bare copper 7×0.22 AWG23 (0,28mm2)
Insulation : Cellular polyolefin Ø1.5mm
Pair : 2 insulated conductors stranded together into a pair
Colour code : 1.White/blue 2.White/orange 3. White/green 4.White/brown
Screen : Aluminium/polyester or Aluminium/polyester/aluminium tape over each single pair
Inner jacket : Fire Retardant SHF1 material, LSZH (nominal thickness 0.8mm, Ø 8.2mm)
Armour : Galvanized steel, tinned copper or bronze wire braid. Coverage ≥80%.
Outer jacket : Black Fire Retardant, UV and MUD Resistant SHF2 material, LSZH (nominal thickness 1.0mm)
Marking : APS Finland – ww/yy – ARMOURED SFTP Flex 4x2x23AWG Cat.6A MUD Resistant NEK606 – IEC60332-3-22 Cat A – TK/lot + meter

Environmental properties and Fire Performances

Degree of acidity of gases : IEC 60754-1, IEC 60754-2 (pH value ≥ 4,3 and Conductivity ≤10µS/mm)
Halogen acid gas : IEC 60754-1, IEC 60754-2 (Halogen acid gas emission ≤ 0.5%)
Smoke Emission : IEC 61034-2, EN 50268-2 (Transmittance) ≥ 60%)
Toxicity of evolved gas : EN50305 9.2
Flame retardant : IEC 60332-1-2
Fire retardant : IEC 60332-3-22 Cat.A
Fire resistant : NO
Ozone resistant : IEC60811-2-1, DIN VDE 0472 part 805 B
LSZH SHF2 : IEC 60092-360
Oil resistant : IEC60811, IRM 903
MUD resistant : NEK606:2009, IEC60092-350
Water absorption : IEC60811-1-3
Water penetration : NO
UV resistant : IEC60811-2-1, ASTM-D-2565-92A
Cold bend & impact : CSA C22.2, UL44

Marine:

Communication cables
Instrumentation cables
Composite cables
Fire Resistant cables

Onshore:

Communication cables
Instrumentation cables
Composite cables
Fire Resistant cables
High temperature cables

Offshore:

Communication cables
Instrumentation Cables
Composite cables
Fire Resistant cables
Deck and High-Lift Cables
Underwater cables
Arctic grade cables